Baryshev, A.; Baselmans, J. J. A.; Reker, S. F.; Hajenius, M.; Gao, J. R.; Klapwijk, T. M.; Vachtomin, Yu.; Maslennikov, S.; Antipov, S.; Voronov, B.; Gol'tsman, G. |
|
|
Title |
Direct detection effect in hot electron bolometer mixers |
Type |
Abstract |
|
Year |
2005 |
Publication |
Proc. 16th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 16th Int. Symp. Space Terahertz Technol. |
|
|
Volume |
|
Issue |
|
Pages |
463-464 |
|
|
Keywords |
NbN HEB mixers, effect of direct detection, direct detection effect |
|
|
Abstract |
NbN phonon cooled hot electron bolometer (HEB) mixers are currently the most sensitive heterodyne detectors at frequencies above 1.2 THz. They combine a good sensitivity (8-15 times the quantum limit), an IF bandwidth of the order of 4-6 GHz and a wide RF bandwidth from 0.7-5.2 THz. However, for use in a space based observatory, such as Herschel, it is of vital importance that the Local Oscillator (LO) power requirement of the mixer is compatible with the low output power of present day THz LO sources. This can be achieved by reducing the mixer volume and critical current. However, the large RF bandwidth and low LO power requirement of such a mixer result in a direct detection effect, characterized by a change in the bias current of the HEB when changing the RF signal from a black body load at 300 K to one at 77 K. As a result the measured sensitivity using a 300 K and 77 K calibration load differs significantly from the small signal sensitivity relevant for astronomical observations. In this article we describe a set of dedicated experiments to characterize the direct detection effect for a small volume quasi-optical NbN phonon cooled HEB mixer. We measure the direct detection effect in a small volume (0.15 μm · 1 μm · 3.5 nm) quasi- optical NbN phonon cooled HEB mixer at 1.6 THz. We found that the small signal sensitivity of the receiver is underestimated by approximately 35% due to the direct detection effect and that the optimal operating point is shifted to higher bias voltages when using calibration loads of 300 K and 77 K. Using a 200 GHz wide band-pass filter at the 4.2 K the direct detection effect virtually disappears. Heterodyne response measurements using water vapor absorption line in a gas cell confirms the existence and a magnitude of a direct detection effect. We also propose a theoretical explanation using uniform electron heating model. This direct detection effect has important implications for the calibration procedure of these receivers in real telescope systems. We are developing Nb HEBs for a large-format, diffusion-cooled hot electron bolometer (HEB) array submillimeter camera. The goal is to produce a 64 pixel array together with the University of Arizona to be used on the HHT on Mt Graham. It is designed to detect in the 850 GHz atmospheric window. We have fabricated Nb HEBs using a new angle- deposition process, which had previously produced high quality Nb-Au bilayer HEB devices at Yale. [1] We have characterized these devices using heterodyne mixing at ~30 GHz to compare to 345 GHz tests at the University of Arizona. We can also directly compare our Nb HEB mixers to SIS mixers in this same 345 GHz system. This allows us to rigorously calibrate the system’s losses and extract the mixer noise temperature in a well characterized mixer block, before undertaking the 850 GHz system. Here we give a report on the initial devices we have fabricated and characterized. * Department of Applied Physics, Yale University ** Department of Astronomy, University of Arizona [1] Applied Physics Letters 84, Number 8; p.1404-7, Feb 23 (2004) |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1475 |
|
Permanent link to this record |
|
|
|
|
Author |
Maslennikov, S. N.; Finkel, M. I.; Antipov, S. V.; Polyakov, S. L.; Zhang, W.; Ozhegov, R.; Vachtomin, Yu. B.; Svechnikov, S. I.; Smirnov, K. V.; Korotetskaya, Yu. P.; Kaurova, N. S.; Gol'tsman, G. N.; Voronov, B. M. |
|
|
Title |
Spiral antenna coupled and directly coupled NbN HEB mixers in the frequency range from 1 to 70 THz |
Type |
Conference Article |
|
Year |
2006 |
Publication |
Proc. 17th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 17th Int. Symp. Space Terahertz Technol. |
|
|
Volume |
|
Issue |
|
Pages |
177-179 |
|
|
Keywords |
directly coupled NbN HEB mixers |
|
|
Abstract |
We investigate both antenna coupled and directly coupled HEB mixers at several LO frequencies within the range of 2.5 THz to 70 THz. H20 (2.5+10.7 THz), and CO2 (30 THz) gas discharge lasers are used as the local oscillators. The noise temperature of antenna coupled mixers is measured at LO frequencies of 2.5 THz, 3.8 THz, and 30 THz. The results for both antenna coupled and directly coupled mixer types are compared. The devices with in—plane dimensions of 5x5 ,um 2 are pumped by LO radiation at 10.7 THz. The directly coupled HEB demonstrates nearly flat dependence of responsivity on frequency in the range of 25+64 THz. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Paris, France |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
386 |
|
Permanent link to this record |
|
|
|
|
Author |
Maslennikov, S.; Antipov, S.; Shishkov, A.; Svechnikov, S.; Voronov, B.; Smirnov, K.; Kaurova, N.; Drakinski, V.; Gol'tsman, G. |
|
|
Title |
NbN HEB mixer noise temperature measurements with hot/cold load mounted inside the helium cryostat at 300 GHz |
Type |
Conference Article |
|
Year |
2002 |
Publication |
Proc. Int. Student Seminar on Microwave Appl. of Novel Physical Phenomena supported by IEEE |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
LETI |
Place of Publication |
St.-Petersburg |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
324 |
|
Permanent link to this record |
|
|
|
|
Author |
Vachtomin, Y. B.; Antipov, S. V.; Maslennikov, S. N.; Smirnov, K. V.; Polyakov, S. L.; Kaurova, N. S.; Grishina, E. V.; Voronov, B. M.; Gol'tsman, G. N. |
|
|
Title |
Noise temperature measurements of NbN phonon-cooled hot electron bolometer mixer at 2.5 and 3.8 THz |
Type |
Conference Article |
|
Year |
2004 |
Publication |
Proc. 15th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 15th Int. Symp. Space Terahertz Technol. |
|
|
Volume |
|
Issue |
|
Pages |
236-241 |
|
|
Keywords |
HEB mixer, NbN, direct detection effect |
|
|
Abstract |
We present the results of noise temperature measurements of NbN phonon-cooled HEB mixers based on a 3.5 nm NbN film deposited on a high-resistivity Si substrate with a 200 nm – thick MgO buffer layer. The mixer element was integrated with a log-periodic spiral antenna. The noise temperature measurements were performed at 2.5 THz and at 3.8 THz local oscillator frequencies for the 3 µm x 0.2 µm active area devices. The best uncorrected receiver noise temperatures found for these frequencies are 1300 K and 3100 K, respectively. A water vapour discharge laser was used as the LO source. We also present the results of direct detection contribution to the measured Y-factor and of a possible error of noise temperature calculation. This error was more than 8% for the mixer with in-plane dimensions of 2.4 x 0.16 µm 2 at the optimal noise temperature point. The use of a mesh filter enabled us to avoid the effect of direct detection and decrease optical losses by 0.5 dB. The paper is concluded by the investigation results of the mixer polarization response. It was shown that the polarization can differ from the circular one at 3.8 THz by more than 2 dB. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Northampton, Massachusetts, USA |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
344 |
|
Permanent link to this record |
|
|
|
|
Author |
Maslennikov, S.; Vachtomin, Yu.; Antipov, S.; Smirnov, K.; Kaurova, N.; Grishina, E.; Voronov, B.; Gol'tsman, G. |
|
|
Title |
NbN HEB mixers for frequencies of 2.5 and 3.8 THz |
Type |
Conference Article |
|
Year |
2004 |
Publication |
Proc. Tenth All-Russian sceintific conference of student-physicists and young sceintists (VNKSF-10) |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Moscow |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
RPLAB @ s @ qoheb_vnksf10_2004 |
Serial |
349 |
|
Permanent link to this record |
|
|
|
|
Author |
Antipov, S. V.; Vachtomin, Yu. B.; Maslennikov, S. N.; Smirnov, K. V.; Kaurova, N. S.; Grishina, E. V.; Voronov, B. M.; Goltsman, G. N. |
|
|
Title |
Noise performance of quasioptical ultrathin NbN hot electron bolometer mixer at 2.5 and 3.8 THz |
Type |
Conference Article |
|
Year |
2004 |
Publication |
Proc. 5-th MSMW |
Abbreviated Journal |
Proc. 5-th MSMW |
|
|
Volume |
2 |
Issue |
|
Pages |
592-594 |
|
|
Keywords |
NbN HEB mixers |
|
|
Abstract |
To put space-based and airborne heterodyne instruments into operation at frequencies above 1 THz the superconducting NbN hot-electron bolometer (HEB) will be incorporated into heterodyne receiver as a mixer. At frequencies above 1.3 THz the sensitivity of the NbN HEB mixers outperform the one of the Schottky diodes and SIS-mixers, and the receiver noise temperature of the NbN HEB mixers increase with frequency. In this paper we present the results of the noise temperature measurements within one batch of NbN HEB mixers based on 3.5 mn thick superconducting NbN film grown on Si substrate with MgO buffer layer at the LO frequencies 2.5 THz and 3.8 THz. |
|
|
Address |
Kharkov, Ukraine |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Kharkov, Ukraine |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
The Fifth International Kharkov Symposium on Physics and Engineering of Microwaves, Millimeter, and Submillimeter Waves (IEEE Cat. No.04EX828) |
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
351 |
|
Permanent link to this record |
|
|
|
|
Author |
Vachtomin, Yu. B.; Antipov, S. V.; Kaurova, N. S.; Maslennikov, S. N.; Smirnov, K. V.; Polyakov, S. L.; Svechnikov, S. I.; Grishina, E. V.; Voronov, B. M.; Gol'tsman, G. N. |
|
|
Title |
Noise temperature, gain bandwidth and local oscillator power of NbN phonon-cooled HEB mixer at terahertz frequenciess |
Type |
Conference Article |
|
Year |
2004 |
Publication |
Proc. 29th IRMMW / 12th THz |
Abbreviated Journal |
Proc. 29th IRMMW / 12th THz |
|
|
Volume |
|
Issue |
|
Pages |
329-330 |
|
|
Keywords |
|
|
|
Abstract |
We present the performances of HEB mixers based on 3.5 nm thick NbN film integrated with log-periodic spiral antenna. The double side-band receiver noise temperature values are 1300 K and 3100 K at 2.5 THz and at 3.8 THz, respectively. The gain bandwidth of the mixer is 4.2 GHz and the noise bandwidth is 5 GHz. The local oscillator power is 1-3 /spl mu/W for mixers with different active area. |
|
|
Address |
Karlsruhe, Germany |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Karlsruhe, Germany |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
RPLAB @ s @ nt_ifb_lopow_qoheb_karlsruhe_2004 |
Serial |
354 |
|
Permanent link to this record |
|
|
|
|
Author |
Kaurova, N. S.; Finkel, M. I.; Maslennikov, S. N.; Vahtomin, Yu. B.; Antipov, S. V.; Smirnov, K. V.; Voronov, B. M.; Gol'tsman, G. N.; Ilyin, K. S. |
|
|
Title |
Submillimeter mixer based on YBa2Cu3O7-x thin film |
Type |
Conference Article |
|
Year |
2004 |
Publication |
Proc. 1-st conf. Fundamental problems of high temperature superconductivity |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
291 |
|
|
Keywords |
HTS, HEB mixer |
|
|
Abstract |
|
|
|
Address |
Moscow-Zvenigorod |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Moscow-Zvenigorod |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
355 |
|
Permanent link to this record |
|
|
|
|
Author |
Cao, Aiqin; Jiang, L.; Chen, S.H.; Antipov, S.V.; Shi, S.C. |
|
|
Title |
IF gain bandwidth of a quasi-optical NbN superconducting HEB mixer |
Type |
Conference Article |
|
Year |
2007 |
Publication |
Proc. International conference on microwave and millimeter wave technology |
Abbreviated Journal |
Proc. ICMMT |
|
|
Volume |
|
Issue |
|
Pages |
1-3 |
|
|
Keywords |
HEB, mixer, gain bandwidth |
|
|
Abstract |
In this paper, the intermediate frequency (IF) gain bandwidth of a quasi-optical NbN superconducting hot-electron bolometer (HEB) mixer is investigated at 500 GHz with an IF system incorporating with a frequency down-converting scheme which is able to sweep the IF signal in a frequency range of 0.3-4 GHz. The IF gain bandwidth of the device is measured to be 1.5 GHz when it is biased at a voltage of the minimum noise temperature, and becomes larger when the bias voltage increases. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Builin |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
RPLAB @ lobanovyury @ |
Serial |
575 |
|
Permanent link to this record |
|
|
|
|
Author |
Antipov, S.; Trifonov, A.; Krause, S.; Meledin, D.; Desmaris, V.; Belitsky, V.; Gol’tsman, G. |
|
|
Title |
Gain bandwidth of NbN HEB mixers on GaN buffer layer operating at 2 THz local oscillator frequency |
Type |
Conference Article |
|
Year |
2017 |
Publication |
Proc. 28th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 28th Int. Symp. Space Terahertz Technol. |
|
|
Volume |
|
Issue |
|
Pages |
147-148 |
|
|
Keywords |
NbN HEB mixers, GaN buffer-layer, IF bandwidth |
|
|
Abstract |
In this paper, we present IF bandwidth measurement results of NbN HEB mixers, which are employing NbN thin films grown on a GaN buffer-layer. The HEB mixers were operated in the heterodyne regime at a bath temperature of approximately 4.5 K and with a local oscillator operating at a frequency of 2 THz. A quantum cascade laser served as the local oscillator and a reference synthesizer based on a BWO generator (130-160 GHz) and a semiconductor superlattice (SSL) frequency multiplier was used as a signal source. By changing the LO frequency it was possible to record the IF response or gain bandwidth of the HEB with a spectrum analyzer at the operation point, which yielded lowest noise temperature. The gain bandwidth that was recorded in the heterodyne regime at 2 THz amounts to approximately 5 GHz and coincides well with a measurement that has been performed at elevated bath temperatures and lower LO frequency of 140 GHz. These findings strongly support that by using a GaN buffer-layer the phonon escape time of NbN HEBs can be significantly lower as compared to e.g. Si substrate, thus, providing higher gain bandwidth. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1175 |
|
Permanent link to this record |