Records |
Author |
Elmanov, Ilia; Elmanova, Anna; Kovalyuk, Vadim; An, Pavel; Goltsman, Gregory |
Title |
Silicon nitride photonic crystal cavity coupled with NV-centers in nanodiamonds |
Type |
Conference Article |
Year |
2020 |
Publication |
Proc. 32-nd EMSS |
Abbreviated Journal |
Proc. 32-nd EMSS |
Volume |
|
Issue |
|
Pages |
344-348 |
Keywords |
|
Abstract |
The development of integrated quantum photonics requires a high efficient excitation and coupling of a single photon source with on-chip devices. In this paper, we show our results of modelling for high-Q photonic crystal cavity, optimized for zero phonon line emission of NV-centers in nanodiamonds. Modelling was performed for the silicon nitride platform and obtained a quality factor equals to 6136 at 637 nm wavelength. |
Address |
NV-centers, nanodiamonds |
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
2724-0029 |
ISBN |
978-88-85741-44-7 |
Medium |
|
Area |
|
Expedition |
|
Conference |
32nd European Modeling & Simulation Symposium |
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1840 |
Permanent link to this record |
|
|
|
Author |
Matyushkin, Yakov; Fedorov, Georgy; Moskotin, Maksim; Danilov, Sergey; Ganichev, Sergey; Goltsman, Gregory |
Title |
Gate-mediated helicity sensitive detectors of terahertz radiation with graphene-based field effect transistors |
Type |
Abstract |
Year |
2020 |
Publication |
Graphene and 2dm Virt. Conf. |
Abbreviated Journal |
Graphene and 2DM Virt. Conf. |
Volume |
|
Issue |
|
Pages |
|
Keywords |
single layer graphene, SLG, CVD, plasmons, FET |
Abstract |
Closing of the so-called terahertz gap results in an increased demand for optoelectronic devices operating in the frequency range from 0.1 to 10 THz. Active plasmonic in field effect devices based on high-mobility two-dimensional electron gas (2DEG) opens up opportunities for creation of on-chip spectrum [1] and polarization [2] analysers. Here we show that single layer graphene (SLG) grown using CVD method can be used for an all-electric helicity sensitive polarization broad analyser of THz radiation. Allourresults show plasmonic nature of response. Devices are made in a configuration ofa field-effect transistor (FET) with a graphene channel that has a length of 2 mkm and a width of 5.5 mkm. Response of opposite polarity to clockwise and anticlockwise polarized radiation is due to special antenna design (see Fig.1c) as follow works [2,3]. Our approaches can be extrapolated to other 2D materials and used as a tool to characterize plasmonic excitations in them. [1]Bandurin, D. A., etal.,Nature Communications, 9(1),(2018),1-8.[2]Drexler, C.,etal.,Journal of Applied Physics, 111(12),(2012),124504.[3]Gorbenko, I. V.,et al.,physica status solidi (RRL)–Rapid Research Letters, 13(3),(2019),1800464. |
Address |
Grenoble, France |
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
Graphene and 2dm Virtual Conference & Expo |
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1743 |
Permanent link to this record |
|
|
|
Author |
Goltsman, Gregory N.; Vachtomin, Yuriy B.; Antipov, Sergey V.; Finkel, Matvey I.; Maslennikov, Sergey N.; Polyakov, Stanislav L.; Svechnikov, Sergey I.; Kaurova, Natalia S.; Grishina, Elisaveta V.; Voronov, Boris M. |
Title |
Low-noise NbN phonon-cooled hot-electron bolometer mixers for terahertz heterodyne receivers |
Type |
Conference Article |
Year |
2005 |
Publication |
Proc. 9-th WMSCI |
Abbreviated Journal |
Proc. 9-th WMSCI |
Volume |
9 |
Issue |
|
Pages |
154-159 |
Keywords |
NbN HEB mixers |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
International Institute of Informatics and Systemics |
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
547 |
Permanent link to this record |
|
|
|
Author |
Meledin, Denis; Pavolotsky, Alexey; Desmaris, Vincent.; Lapkin, Igor; Risacher, Christophe; Perez, Victor; Henke, Douglas; Nystrom, Olle; Sundin, Erik; Dochev, Dimitar; Pantaleev, Miroslav; Fredrixon, Mathias; Strandberg, Magnus; Voronov, Boris; Goltsman, Gregory; Belitsky, Victor |
Title |
A 1.3-THz balanced waveguide HEB mixer for the APEX telescope |
Type |
Journal Article |
Year |
2009 |
Publication |
IEEE Trans. Microw. Theory Techn. |
Abbreviated Journal |
|
Volume |
57 |
Issue |
1 |
Pages |
89-98 |
Keywords |
HEB, mixer, waveguide, balanced, NbN |
Abstract |
In this paper, we report about the development, fabrication, and characterization of a balanced waveguide hot electron bolometer (HEB) receiver for the Atacama Pathfinder EXperiment telescope covering the frequency band of 1.25–1.39 THz. The receiver uses a quadrature balanced scheme and two HEB mixers, fabricated from 4- to 5-nm-thick NbN film deposited on crystalline quartz substrate with an MgO buffer layer in between. We employed a novel micromachining method to produce all-metal waveguide parts at submicrometer accuracy (the main-mode waveguide dimensions are 90×180 μm). We present details on the mixer design and measurement results, including receiver noise performance, stability and “first-light†at the telescope site. The receiver yields a double-sideband noise temperature averaged over the RF band below 1200 K, and outstanding stability with a spectroscopic Allan time more than 200 s. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0018-9480 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
RPLAB @ lobanovyury @ |
Serial |
554 |
Permanent link to this record |
|
|
|
Author |
Ryabchun, Sergey; Tong, Cheuk-Yu Edward; Paine, Scott; Lobanov, Yury; Blundell, Raymond; Goltsman, Gregory |
Title |
Temperature resolution of an HEB receiver at 810 GHz |
Type |
Journal Article |
Year |
2009 |
Publication |
IEEE Trans. Appl. Supercond. |
Abbreviated Journal |
IEEE Trans. Appl. Supercond. |
Volume |
19 |
Issue |
3 |
Pages |
293-296 |
Keywords |
HEB mixer |
Abstract |
We present the results of direct measurements of the temperature resolution of an HEB receiver operating at 810 GHz, in both continuum and spectroscopic modes. In the continuum mode, the input of the receiver was switched between black bodies with different physical temperatures. With a system noise temperature of around 1100 K, the receiver was able to resolve loads which differed in temperature by about 1 K over an integration time of 5 seconds. This resolution is significantly worse than the value of 0.07 K given by the radiometer equation. In the spectroscopic mode, a gas cell filled with carbonyl sulphide (OCS) gas was used and the emission line at 813.3537060 GHz was measured using the receiver in conjunction with a digital spectrometer. From the observed spectra, we determined that the measurement uncertainty of the equivalent emission temperature was 2.8 K for an integration time of 0.25 seconds and a spectral resolution of 12 MHz, compared to a 1.4 K temperature resolution given by the radiometer equation. This relative improvement is due to the fact that at short integration times the contribution from 1/f noise and drift are less dominant. In both modes, the temperature resolution was improved by about 40% with the use of a feedback loop which adjusted the level of an injected microwave radiation to maintain a constant operating current of the HEB mixer. This stabilization scheme has proved to be very effective to keep the temperature resolution of the HEB receiver to close to the theoretical value given by the radiometer equation. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
636 |
Permanent link to this record |