Records |
Links |
|
Author |
Goltsman, Gregory |
|
|
Title |
Superconducting thin film nanostructures as terahertz and infrared heterodyne and direct detectors |
Type |
Conference Article |
|
Year |
2017 |
Publication |
16th ISEC |
Abbreviated Journal |
16th ISEC |
|
|
Volume |
|
Issue |
|
Pages |
Th-I-QTE-03 (1 to 3) |
|
|
Keywords |
waveguide SSPD, SNSPD |
|
|
Abstract |
We present our recent achievements in the development of superconducting nanowire single-photon detectors (SNSPDs) integrated with optical waveguides on a chip. We demonstrate both single-photon counting with up to 90% on-chipquantum-efficiency (OCDE), and the heterodyne mixing with a close to the quantum limit sensitivity at the telecommunication wavelength using single device. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
IEEE/CSC & ESAS Superconductivity News Forum |
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1745 |
|
Permanent link to this record |
|
|
|
|
Author |
Goltsman, Gregory N. |
|
|
Title |
Development and applications of terahertz hot electron bolometers |
Type |
Abstract |
|
Year |
2021 |
Publication |
1st Moscow Int. Conf. on Submillimeter and Millimeter Astronomy: Objectives and Instruments |
Abbreviated Journal |
1st Moscow Int. Conf. on Submillimeter and Millimeter Astronomy: Objectives and Instruments |
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
The development of techniques and technologies for the deposition of ultrathin superconducting films, the creation of superconducting structures on a nanometer scale is the basis of significant progress in the field of superconducting receiving systems. Ultrathin NbN films are the basis for a wide range of record-breaking hot electron devices: direct and heterodyne terahertz detectors. Terahertz receivers are especially in demand in high-resolution spectroscopy for astronomical, atmospheric, and medical research. HEB receivers are widely used in terahertz radio astronomy. For example, the Dutch SRON Institute is preparing a project for the GUSTO hot air balloon telescope with a HEB mixer array at 1.4 THz and 1.9 THz. A 5-meter Chinese terahertz telescope DATE5 with HEB mixers at 1.4 THz is installed at the South Pole. The Stratospheric Observatory (SOFIA) uses HEB mixer matrices in the GREAT instrument operating in the 1.2 – 4.7 THz range. It is planned to implement the international project Origins Space Telescope (OST) in the far infrared region based on HEB receivers. The Japanese project Smiles-2 will allow measurements at 1.8 THz in the upper layers of the stratosphere and mesosphere. The development of the Millimetron space observatory continues in Russia. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
First Moscow International Conference on Submillimeter and Millimeter Astronomy: Objectives and Instruments, Astro Space Center, Moscow, 12-16 April 2021, id. 2 |
|
|
Notes |
Downloaded from https://millimetron.ru/conference_2021/Goltsman.pdf; Author: Sergey; Last modification: 2021-04-14 |
Approved |
no |
|
|
Call Number |
|
Serial |
1771 |
|
Permanent link to this record |
|
|
|
|
Author |
Elmanov, Ilia; Elmanova, Anna; Kovalyuk, Vadim; An, Pavel; Goltsman, Gregory |
|
|
Title |
Integrated contra-directional coupler for NV-centers photon filtering |
Type |
Conference Article |
|
Year |
2020 |
Publication |
Proc. 32-nd EMSS |
Abbreviated Journal |
Proc. 32-nd EMSS |
|
|
Volume |
|
Issue |
|
Pages |
354-360 |
|
|
Keywords |
NV-centers, nanodiamonds, quantum photonic integrated circuits, contra-direction coupler, Bragg gratings |
|
|
Abstract |
We modelled an integrated optical contra-directional coupler on silicon nitride platform. Performance of the filter was studied depending on different parameters, including the grating period and the height of teeth of the Bragg grating near 637 nm operation wavelength. The obtained results can be used for a design and fabrication of quantum photonic integrated circuits with on-chip single-photon NV-centers in nanodiamonds. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2724-0029 |
ISBN |
978-88-85741-44-7 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
32nd European Modeling & Simulation Symposium |
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1839 |
|
Permanent link to this record |
|
|
|
|
Author |
Elmanov, Ilia; Elmanova, Anna; Kovalyuk, Vadim; An, Pavel; Goltsman, Gregory |
|
|
Title |
Silicon nitride photonic crystal cavity coupled with NV-centers in nanodiamonds |
Type |
Conference Article |
|
Year |
2020 |
Publication |
Proc. 32-nd EMSS |
Abbreviated Journal |
Proc. 32-nd EMSS |
|
|
Volume |
|
Issue |
|
Pages |
344-348 |
|
|
Keywords |
|
|
|
Abstract |
The development of integrated quantum photonics requires a high efficient excitation and coupling of a single photon source with on-chip devices. In this paper, we show our results of modelling for high-Q photonic crystal cavity, optimized for zero phonon line emission of NV-centers in nanodiamonds. Modelling was performed for the silicon nitride platform and obtained a quality factor equals to 6136 at 637 nm wavelength. |
|
|
Address |
NV-centers, nanodiamonds |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2724-0029 |
ISBN |
978-88-85741-44-7 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
32nd European Modeling & Simulation Symposium |
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1840 |
|
Permanent link to this record |
|
|
|
|
Author |
Meledin, Denis; Pavolotsky, Alexey; Desmaris, Vincent.; Lapkin, Igor; Risacher, Christophe; Perez, Victor; Henke, Douglas; Nystrom, Olle; Sundin, Erik; Dochev, Dimitar; Pantaleev, Miroslav; Fredrixon, Mathias; Strandberg, Magnus; Voronov, Boris; Goltsman, Gregory; Belitsky, Victor |
|
|
Title |
A 1.3-THz balanced waveguide HEB mixer for the APEX telescope |
Type |
Journal Article |
|
Year |
2009 |
Publication |
IEEE Trans. Microw. Theory Techn. |
Abbreviated Journal |
|
|
|
Volume |
57 |
Issue |
1 |
Pages |
89-98 |
|
|
Keywords |
HEB, mixer, waveguide, balanced, NbN |
|
|
Abstract |
In this paper, we report about the development, fabrication, and characterization of a balanced waveguide hot electron bolometer (HEB) receiver for the Atacama Pathfinder EXperiment telescope covering the frequency band of 1.25–1.39 THz. The receiver uses a quadrature balanced scheme and two HEB mixers, fabricated from 4- to 5-nm-thick NbN film deposited on crystalline quartz substrate with an MgO buffer layer in between. We employed a novel micromachining method to produce all-metal waveguide parts at submicrometer accuracy (the main-mode waveguide dimensions are 90×180 μm). We present details on the mixer design and measurement results, including receiver noise performance, stability and “first-light†at the telescope site. The receiver yields a double-sideband noise temperature averaged over the RF band below 1200 K, and outstanding stability with a spectroscopic Allan time more than 200 s. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0018-9480 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
RPLAB @ lobanovyury @ |
Serial |
554 |
|
Permanent link to this record |
|
|
|
|
Author |
Pentin, Ivan; Finkel, Matvey; Maslennikov, Sergey; Vakhtomin, Yuri; Smirnov, Konstantin; Kaurova, Nataliya; Goltsman, Gregory |
|
|
Title |
Superconducting hot-electron-bolometer mixers for the mid-IR |
Type |
Journal Article |
|
Year |
2017 |
Publication |
Rus. J. Radio Electron. |
Abbreviated Journal |
Rus. J. Radio Electron. |
|
|
Volume |
|
Issue |
10 |
Pages |
|
|
|
Keywords |
IR NbN HEB mixers |
|
|
Abstract |
The work presents the result of development of the NbN superconducting hot-electron-bolometer (HEB) mixer. The sensitive element of the mixer is directly coupled to mid-IR radiation, and doesn’t have planar metallic antenna. Investigations of noise characteristics of NbN HEB mixer were performed at the frequency 28.4 THz (λ = 10.6 µm) by using gas-discharge CW CO2-laser without consideration of optical and electrical losses in the heterodyne receiver. The noise temperature of NbN HEB mixer with the size of the sensitive element 10 µm × 10 µm was 2320 K (~ 1.5hν/kB) at the heterodyne frequency of 28.4 THz. The noise temperature was determined by measuring the Y-factor taking into account the term which describes fluctuations of zero-point oscillations in accordance with the fluctuation-dissipation theorem of Calle-Welton. Isothermal method was used to estimate the absorbed heterodyne radiation power which was 9 µW at the optimal operating point for the minimum noise temperature of NbN HEB mixer. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
Russian |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1684-1719 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
http://jre.cplire.ru/jre/oct17/9/abstract.html (Russian) Гетеродинный приемник со сверхпроводниковым смесителем на эффекте электронного разогрева для среднего инфракрасного диапазона |
Approved |
no |
|
|
Call Number |
|
Serial |
1747 |
|
Permanent link to this record |
|
|
|
|
Author |
Dauler, Eric; Kerman, Andrew; Robinson, Bryan; Yang, Joel; Voronov, Boris; Goltsman, Gregory; Hamilton, Scott; Berggren, Karl |
|
|
Title |
Photon-number-resolution with sub-30-ps timing using multi-element superconducting nanowire single photon detectors |
Type |
Journal Article |
|
Year |
2009 |
Publication |
J. Modern Opt. |
Abbreviated Journal |
J. Modern Opt. |
|
|
Volume |
56 |
Issue |
2 |
Pages |
364-373 |
|
|
Keywords |
PNR SSPD; SNSPD; photon-number-resolution; superconducting nanowire single photon detector; timing jitter; system detection efficiency |
|
|
Abstract |
A photon-number-resolving detector based on a four-element superconducting nanowire single photon detector is demonstrated to have sub-30-ps resolution in measuring the arrival time of individual photons. This detector can be used to characterize the photon statistics of non-pulsed light sources and to mitigate dead-time effects in high-speed photon counting applications. Furthermore, a 25% system detection efficiency at 1550 nm was demonstrated, making the detector useful for both low-flux source characterization and high-speed photon-counting and quantum communication applications. The design, fabrication and testing of this detector are described, and a comparison between the measured and theoretical performance is presented. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
RPLAB @ gujma @ |
Serial |
700 |
|
Permanent link to this record |
|
|
|
|
Author |
Smirnov, Konstantin; Vachtomin, Yury; Divochiy, Alexander; Antipov, Andrey; Goltsman, Gregory |
|
|
Title |
Dependence of dark count rates in superconducting single photon detectors on the filtering effect of standard single mode optical fibers |
Type |
Journal Article |
|
Year |
2015 |
Publication |
Appl. Phys. Express |
Abbreviated Journal |
Appl. Phys. Express |
|
|
Volume |
8 |
Issue |
2 |
Pages |
022501 (1 to 4) |
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
IOP Publishing |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1882-0778 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
RPLAB @ sasha @ smirnov2015dependence |
Serial |
1049 |
|
Permanent link to this record |
|
|
|
|
Author |
Mohan, Nishant; Minaeva, Olga; Goltsman, Gregory N.; Saleh, Mohammed F.; Nasr, Magued B.; Sergienko, Alexander V.; Saleh, Bahaa E.; Teich, Malvin C. |
|
|
Title |
Ultrabroadband coherence-domain imaging using parametric downconversion and superconducting single-photon detectors at 1064 nm |
Type |
Journal Article |
|
Year |
2009 |
Publication |
Appl. Opt. |
Abbreviated Journal |
Appl. Opt. |
|
|
Volume |
48 |
Issue |
20 |
Pages |
4009–4017 |
|
|
Keywords |
SSPD, SNSPD, SPAD |
|
|
Abstract |
Coherence-domain imaging systems can be operated in a single-photon-counting mode, offering low detector noise; this in turn leads to increased sensitivity for weak light sources and weakly reflecting samples. We have demonstrated that excellent axial resolution can be obtained in a photon-counting coherence-domain imaging (CDI) system that uses light generated via spontaneous parametric downconversion (SPDC) in a chirped periodically poled stoichiometric lithium tantalate (chirped-PPSLT) structure, in conjunction with a niobium nitride superconducting single-photon detector (SSPD). The bandwidth of the light generated via SPDC, as well as the bandwidth over which the SSPD is sensitive, can extend over a wavelength region that stretches from 700 to 1500 nm. This ultrabroad wavelength band offers a near-ideal combination of deep penetration and ultrahigh axial resolution for the imaging of biological tissue. The generation of SPDC light of adjustable bandwidth in the vicinity of 1064 nm, via the use of chirped-PPSLT structures, had not been previously achieved. To demonstrate the usefulness of this technique, we construct images for a hierarchy of samples of increasing complexity: a mirror, a nitrocellulose membrane, and a biological sample comprising onion-skin cells. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
RPLAB @ gujma @ |
Serial |
652 |
|
Permanent link to this record |
|
|
|
|
Author |
Ryabchun, Sergey; Tong, Cheuk-Yu Edward; Paine, Scott; Lobanov, Yury; Blundell, Raymond; Goltsman, Gregory |
|
|
Title |
Temperature resolution of an HEB receiver at 810 GHz |
Type |
Journal Article |
|
Year |
2009 |
Publication |
IEEE Trans. Appl. Supercond. |
Abbreviated Journal |
IEEE Trans. Appl. Supercond. |
|
|
Volume |
19 |
Issue |
3 |
Pages |
293-296 |
|
|
Keywords |
HEB mixer |
|
|
Abstract |
We present the results of direct measurements of the temperature resolution of an HEB receiver operating at 810 GHz, in both continuum and spectroscopic modes. In the continuum mode, the input of the receiver was switched between black bodies with different physical temperatures. With a system noise temperature of around 1100 K, the receiver was able to resolve loads which differed in temperature by about 1 K over an integration time of 5 seconds. This resolution is significantly worse than the value of 0.07 K given by the radiometer equation. In the spectroscopic mode, a gas cell filled with carbonyl sulphide (OCS) gas was used and the emission line at 813.3537060 GHz was measured using the receiver in conjunction with a digital spectrometer. From the observed spectra, we determined that the measurement uncertainty of the equivalent emission temperature was 2.8 K for an integration time of 0.25 seconds and a spectral resolution of 12 MHz, compared to a 1.4 K temperature resolution given by the radiometer equation. This relative improvement is due to the fact that at short integration times the contribution from 1/f noise and drift are less dominant. In both modes, the temperature resolution was improved by about 40% with the use of a feedback loop which adjusted the level of an injected microwave radiation to maintain a constant operating current of the HEB mixer. This stabilization scheme has proved to be very effective to keep the temperature resolution of the HEB receiver to close to the theoretical value given by the radiometer equation. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
636 |
|