|   | 
Details
   web
Records
Author Gousev, Yu. P.; Semenov, A. D.; Pechen, E. V.; Varlashkin, A. V.; Nebosis, R. S.; Renk K. F
Title Coupling of terahertz radiation to a high-Т(с) superconducting hot electron bolometer mixer Type Journal Article
Year 1996 Publication Abbreviated Journal Appl. Phys. Lett.,
Volume 69 Issue Pages 691-693
Keywords
Abstract (up) We report on efficient coupling of THz radiation to a high-T(c) superconducting hot electron bolometer that is suitable for heterodyne detection. Our quasioptical system consisted of a planar self-complementary spiral antenna on a dielectric substrate clamped to an extended hyperhemispherical lens. The antenna was integrated into a co-planar line for broadband intermediate frequency matching. Measurements in the homodyne regime at a frequency of 2.5 THz showed a radiation pattern with a beam width of 1° and a coupling efficiency of 0.1. We measured, at an intermediate frequency of 1.5 GHz, an output noise temperature of'160 K and estimated for the device, operated in the heterodyne regime, a system noise temperature of 30 000 K. We also discuss possibilities of significant improvement of the sensitivity.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number RPLAB @ atomics90 @ Serial 958
Permanent link to this record
 

 
Author Nebosis, R. S.; Steinke, R.; Lang, P. T.; Schatz, W.; Heusinger, M. A.; Renk, K. F.; Gol’tsman, G. N.; Karasik, B. S.; Semenov, A. D.; Gershenzon, E. M.
Title Picosecond YBa2Cu3O7−δdetector for far‐infrared radiation Type Journal Article
Year 1992 Publication J. Appl. Phys. Abbreviated Journal J. Appl. Phys.
Volume 72 Issue 11 Pages 5496-5499
Keywords YBCO HTS detectors
Abstract (up) We report on a picosecond YBa2Cu3O7−δ detector for far‐infrared radiation. The detector, consisting of a current carrying structure cooled to liquid‐nitrogen temperature, was studied by use of ultrashort laser pulses from an optically pumped far‐infrared laser in the frequency range from 25 to 215 cm−1. We found that the sensitivity (1 mV/W) was almost constant in this frequency range. We estimated a noise equivalent power of less than 5×10−7 W Hz−1/2. Taking into account the results of a mixing experiment (in the frequency range from 4 to 30 cm−1) we suggest that the response time of the detector was few picoseconds.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0021-8979 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 1668
Permanent link to this record
 

 
Author Gousev, Y. P.; Gol'tsman, G. N.; Karasik, B. S.; Gershenzon, E. M.; Semenov, A. D.; Barowski, H. S.; Nebosis, R. S.; Renk, K. F.
Title Quasioptical superconducting hot electron bolometer for submillmeter waves Type Journal Article
Year 1996 Publication Int. J. of Infrared and Millimeter Waves Abbreviated Journal Int. J. of Infrared and Millimeter Waves
Volume 17 Issue 2 Pages 317-331
Keywords NbN HEB
Abstract (up) We report on a superconducting hot electron bolometer coupled to radiation via a broadband antenna. The bolometer, a structured NbN film, was patterned on a thin dielectric membrane between terminals of a gold slotline antenna. We investigated the response to submillimeter radiation (wave-lengths ∼ 0.1 mm to 0.7 mm) in the fundamental Gaussian mode. We found that the directivity of the antenna was constant within a factor of 2.5 through the whole experimental range. The noise equivalent power of the bolometer at 119 µm was ∼ 3 · 10−13 W/Hz1/2; a time constant of ∼ 160 ps was estimated.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0195-9271 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 1618
Permanent link to this record
 

 
Author Semenov, A. D.; Gousev, Y. P.; Nebosis, R. S.; Renk, K. F.; Yagoubov, P.; Voronov, B. M.; Gol’tsman, G. N.; Syomash, V. D.; Gershenzon, E. M.
Title Heterodyne detection of THz radiation with a superconducting hot‐electron bolometer mixer Type Journal Article
Year 1996 Publication Appl. Phys. Lett. Abbreviated Journal Appl. Phys. Lett.
Volume 69 Issue 2 Pages 260-262
Keywords NbN HEB mixers
Abstract (up) We report on the use of a superconducting hot‐electron bolometer mixer for heterodyne detection of terahertz radiation. Radiation with a wavelength of 119 μm was coupled to the mixer, a NbN microbridge, by a hybrid quasioptical antenna consisting of an extended hyperhemispherical lens and a planar logarithmic spiral antenna. We found, at an intermediate frequency of 1.5 GHz, a system double side band noise temperature of ≊40 000 K and conversion losses of 25 dB. We also discuss the possibilities of further improvement of the mixer performance.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-6951 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 1610
Permanent link to this record
 

 
Author Nebosis, R. S.; Heusinger, M. A.; Semenov, A. D.; Lang, P. T.; Schatz, W.; Steinke, R.; Renk, K. F.; Gol'tsman, G. N.; Karasik, B. S.; Gershenzon, E. M.
Title Ultrafast photoresponse of an YBa2Cu3O7-δ film to far-infrared radiation pulses Type Journal Article
Year 1993 Publication Opt. Lett. Abbreviated Journal Opt. Lett.
Volume 18 Issue 2 Pages 96-97
Keywords YBCO HTS detectors
Abstract (up) We report the observation of an ultrafast photoresponse of a high-T(c), film to far-infrared radiation pulses. The response of a sample, consisting of a current-carrying structured YBa(2)Cu(3)O(7-delta) film cooled to liquid-nitrogen temperature, was studied by use of ultrashort laser pulses from an optically pumped far-infrared laser in the frequency range from 0.7 to 7 THz. We found that the response time was limited by the time resolution, 120 ps, of our electronic registration equipment.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0146-9592 ISBN Medium
Area Expedition Conference
Notes PMID:19802049 Approved no
Call Number Serial 1660
Permanent link to this record