Details
   web
Records
Author Nebosis, R. S.; Semenov, A. D.; Gousev, Yu. P.; Renk, K. F.
Title Rigorous analysis of a superconducting hot-electron bolometer mixer: theory and comparision with experiment Type (up) Conference Article
Year 1996 Publication Proc. 7th Int. Symp. Space Terahertz Technol. Abbreviated Journal
Volume Issue Pages 601-613
Keywords HEB mixer, model, conversion gain, noise temperature, impedance, 2.5 THz
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Charlottesville, Virginia, USA Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 605
Permanent link to this record
 

 
Author Semenov, A. D.; Sergeev, A. V.; Kouminov, P.; Goghidze, I. G.; Heusinger, M. A.; Nebosis, R. S.; Gol'tsman, G. N.; Gershenzon, E. M.; Renk, K. F.
Title Transparency of YBCO film/substrate interfaces for thermal phonons determined by photoresponse measurements Type (up) Conference Article
Year 1993 Publication Proc. 1st European Conf. on Appl. Supercond. Abbreviated Journal Proc. 1st European Conf. on Appl. Supercond.
Volume 2 Issue Pages 1443-1446
Keywords YBCO HTS detectors
Abstract Direct measurements of the thermal boundary resistance were performed by means of the stationary method. In this approach the temperature of an electrically heated film is controlled by its dc resistance while an additional film on the same substrate is used as a thermometer monitoring substrate temperature. The temperature field in the substrate is then calculated to deduce the Kapitza temperature step at the interface between the heated strip and the substrate. The main statement of all afore-said papers is that experimental values of the thermal boundary resistance are too large to be explained by the acoustic mismatch model. In this paper we investigate transparency of YBaCuO film/substrate interfaces for thermal phonons by means of photoresponse measurements. We show that our data are in reasonable agreement with the acoustic mismatch theory.
Address
Corporate Author Thesis
Publisher Place of Publication Editor Freyhardt, H. C.
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN 3-88355-197-X Medium
Area Expedition Conference 1st European conference on applied superconductivity
Notes Approved no
Call Number Serial 1661
Permanent link to this record
 

 
Author Heusinger, M. A.; Nebosis,R. S.; Schatz, W.; Renk, K. F.; Gol’tsman, G. N.; Karasik, B. S.; Semenov, A. D.; Gershenzon, E. M.
Title Temperature dependence of bolometric and non-bolometric photoresponse of a structured YBa2Cu3O7-δ thin film Type (up) Conference Article
Year 1993 Publication Phonon Scattering in Condensed Matter VII. Springer Series in Solid-State Sciences Abbreviated Journal Phonon Scattering in Condensed Matter VII. Springer Series in Solid-State Sciences
Volume 112 Issue Pages 193-195
Keywords YBCO HTS detectors
Abstract We investigated the temperature dependence of the transient voltage photoresponse of a current biased structured YBa2Cu3O7−δ thin film in its transition temperature region, around 79 K. Both, picosecond nonbolometric and nanosecond bolometric response to ultrashort far-infrared laser pulses were found for frequencies between 25 cm−1 and 215 cm−1. We will discuss optimum conditions for radiation detection and present an analysis of the dynamical behaviour of excited high T c thin films.
Address
Corporate Author Thesis
Publisher Place of Publication Editor Meissner, M.; Pohl, R. O.
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference Seventh International Conference, Cornell University, Ithaca, New York, August 3-7, 1992
Notes Approved no
Call Number Serial 1663
Permanent link to this record
 

 
Author Gol'tsman, G. N.; Semenov, A. D.; Gousev, Y. P.; Zorin, M. A.; Gogidze, I. G.; Gershenzon, E. M.; Lang, P. T.; Knott, W. J.; Renk, K. F.
Title Sensitive picosecond NbN detector for radiation from millimetre wavelengths to visible light Type (up) Journal Article
Year 1991 Publication Supercond. Sci. Technol. Abbreviated Journal Supercond. Sci. Technol.
Volume 4 Issue 9 Pages 453-456
Keywords NbN HEB detectors
Abstract The authors report on the application of a broad-band NbN film detector which has high sensitivity and picosecond response time for detection of radiation from millimetre wavelengths to visible light. From a study of amplitude modulated radiation of backward-wave tubes and picosecond pulses from gas and solid state lasers at wavelengths between 2 mm and 0.53 mu m, they found a detectivity of 1010 W-1 cm Hz-1/2 and a response time of less than 50 ps at T=10 K. The characteristics were provided by using a 150 AA thick NbN film patterned into a structure of micron strips. According to the proposed detection mechanism, namely electron heating, they expect an intrinsic response time of approximately 20 ps at the same temperature.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0953-2048 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 242
Permanent link to this record
 

 
Author Gousev, Yu. P.; Gol'tsman, G. N.; Semenov, A. D.; Gershenzon, E. M.; Nebosis, R. S.; Heusinger, M. A.; Renk, K. F.
Title Broadband ultrafast superconducting NbN detector for electromagnetic radiation Type (up) Journal Article
Year 1994 Publication J. Appl. Phys. Abbreviated Journal J. Appl. Phys.
Volume 75 Issue 7 Pages 3695-3697
Keywords NbN HEB
Abstract An ultrafast detector that is sensitive to radiation in a broad spectral range from submillimeter waves to visible light is reported. It consists of a structured NbN thin film cooled to a temperature below Tc (∼11 K). Using 20 ps pulses of a GaAs laser, we observed signal pulses with both rise and decay time of about 50 ps. From the analysis of a mixing experiment with submillimeter radiation we estimate an intrinsic response time of the detector of ∼12 ps. The sensitivity was found to be similar for the near‐infrared and submillimeter radiation. Broadband sensitivity and short response time are attributed to a quasiparticle heating effect.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 252
Permanent link to this record