|   | 
Details
   web
Records
Author (up) Iomdina, E. N.; Seliverstov, S. V.; Teplyakova, K. O.; Jani, E. V.; Pozdniakova, V. V.; Polyakova, O. N.; Goltsman, G. N.
Title Terahertz scanning of the rabbit cornea with experimental UVB-induced damage: in vivo assessment of hydration and its verification Type Journal Article
Year 2021 Publication J. Biomed. Opt. Abbreviated Journal J. Biomed. Opt.
Volume 26 Issue 4 Pages
Keywords medicine; scheimpflug imaging; UVB; confocal microscopy; cornea; optical coherent tomography; rabbit eyes; terahertz radiation
Abstract SIGNIFICANCE: Water content plays a vital role in the normally functioning visual system; even a minor disruption in the water balance may be harmful. Today, no direct method exists for corneal hydration assessment, while it could be instrumental in early diagnosis and control of a variety of eye diseases. The use of terahertz (THz) radiation, which is highly sensitive to water content, appears to be very promising. AIM: To find out how THz scanning parameters of corneal tissue measured by an experimental setup, specially developed for in vivo contactless estimations of corneal reflectivity coefficient (RC), are related to pathological changes in the cornea caused by B-band ultraviolet (UVB) exposure. APPROACH: The setup was tested on rabbit eyes in vivo. Prior to the course of UVB irradiation and 1, 5, and 30 days after it, a series of examinations of the corneal state was made. At the same time points, corneal hydration was assessed by measuring RC. RESULTS: The obtained data confirmed the negative impact of UVB irradiation course on the intensity of tear production and on the corneal thickness and optical parameters. A significant (1.8 times) increase in RC on the 5th day after the irradiation course, followed by a slight decrease on the 30th day after it was revealed. The RC increase measured 5 days after the UVB irradiation course generally corresponded to the increase (by a factor of 1.3) of tear production. RC increase occurred with the corneal edema, which was manifested by corneal thickening (by 18.2% in the middle area and 17.6% in corneal periphery) and an increased volume of corneal tissue (by 17.6%). CONCLUSIONS: Our results demonstrate that the proposed approach can be used for in vivo contactless estimation of the reflectivity of rabbit cornea in the THz range and, thereby, of cornea hydration.
Address National Research University Higher School of Economics, Moscow Institute of Electronics and Mathema, Russia
Corporate Author Thesis
Publisher Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1083-3668 ISBN Medium
Area Expedition Conference
Notes PMID:33834684; PMCID:PMC8027227 Approved no
Call Number Serial 1258
Permanent link to this record
 

 
Author (up) Neroev, V. V.; Iomdina, E. N.; Khandzhyan, A. T.; Khodzhabekyan, N. V.; Sengaeva, M. D.; Ivanova, A. V.; Seliverstov, S. V.; Teplyakova, K. O.; Goltsman, G. N.
Title Experimental study of the effect of corneal hydration and its biomechanical properties on the results of photorefractive keratectomy Type Journal Article
Year 2021 Publication Vestn. Oftalmol. Abbreviated Journal Vestn. Oftalmol.
Volume 137 Issue 3 Pages 68-75
Keywords THz scanning, cornea, photorefractive keratectomy, medicine
Abstract Water content in the cornea may affect the outcome of its excimer laser ablation, especially in presbyopic patients with myopic refraction. This hypothesis can be tested by scanning the cornea in the terahertz (THz) range to determine its hydration level.

Purpose: To study the effect of hydration of the cornea determined by non-contact THz scanning and its biomechanical parameters on the results of photorefractive keratectomy (PRK) in an experiment.

Material and methods: PRK was performed using the Nidek EC-5000 QUEST excimer laser on 8 rabbit eyes. Corneal hydration was evaluated by determining the reflection coefficient (RC) in the THz electromagnetic radiation range before PRK, after 3-5 days, and after 1, 2, 3, and 4 months. Clinical examination included autorefractometry, assessment of corneal thickness and other anatomical and optical parameters of the anterior eye segment (Galilei G6, Ziemer Ophthalmic Systems AG 6.0.2, Switzerland), measurement of corneal hysteresis (CH) and corneal resistance factor (CRF) using the Ocular Response Analyzer (ORA; Reichert, USA), as well as tear production (Schirmer test).

Results: The initial water content in the cornea has a significant effect on the thickness of the removed layer, i.e. on the PRK effect, with correlation coefficient of Rs= -0.976 (p<0.01). The correlation between CH and the ablation depth is less pronounced (Rs=0.643), and CRF had no correlation with it (Rs= -0.089). Biomechanical indicators of the cornea depend on its hydration: changes in CH and CRF after excimer laser ablation qualitatively coincide with changes in RC, the correlation coefficient between RC and the initial value of CH is R= -0.619 (moderate negative correlation).

Conclusion: THz scanning is an effective non-contact technology for monitoring corneal hydration level. The mismatch of the hypoeffect of keratorefractive excimer laser intervention planned for patients with presbyopia with the actual outcome can be caused by individual decrease in the initial water content in the cornea.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Russian Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 1794
Permanent link to this record
 

 
Author (up) Seliverstov, S. V.; Anfertyev, V. A.; Tretyakov, I. V.; Ozheredov, I. A.; Solyankin, P. M.; Revin, L. S.; Vaks, V. L.; Rusova, A. A.; Goltsman, G. N.; Shkurinov, A. P.
Title Terahertz heterodyne receiver with an electron-heating mixer and a heterodyne based on the quantum-cascade laser Type Journal Article
Year 2017 Publication Radiophys. Quant. Electron. Abbreviated Journal Radiophys. Quant. Electron.
Volume 60 Issue 7 Pages 518-524
Keywords NbN HEB mixer, QCL
Abstract We study characteristics of the laboratory prototype of a terahertz heterodyne receiver with an electron-heating mixer and a heterodyne based on the quantum-cascade laser. The results obtained demonstrate the possibility to use this receiver as a basis for creation of a high-sensitivity terahertz spectrometer, which can be used in many basic and practical applications. A significant advantage of this receiver will be the possibility of placing the mixer and heterodyne in the same cryostat, which will reduce the device dimensions considerably. The obtained experimental results are analyzed, and methods of optimizing the parameters of the receiver are proposed.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0033-8443 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 1322
Permanent link to this record
 

 
Author (up) Seliverstov, S. V.; Rusova, A. A.; Kaurova, N. S.; Voronov, B. M.; Goltsman, G. N.
Title Attojoule energy resolution of direct detector based on hot electron bolometer Type Conference Article
Year 2016 Publication J. Phys.: Conf. Ser. Abbreviated Journal J. Phys.: Conf. Ser.
Volume 741 Issue Pages 012165 (1 to 5)
Keywords NbN HEB detector
Abstract We characterize superconducting antenna-coupled NbN hot-electron bolometer (HEB) for direct detection of THz radiation operating at a temperature of 9.0 K. At signal frequency of 2.5 THz, the measured value of the optical noise equivalent power is 2.0×10-13 W-Hz-0.5. The estimated value of the energy resolution is about 1.5 aJ. This value was confirmed in the experiment with pulsed 1.55-μm laser employed as a radiation source. The directly measured detector energy resolution is 2 aJ. The obtained risetime of pulses from the detector is 130 ps. This value was determined by the properties of the RF line. These characteristics make our detector a device-of-choice for a number of practical applications associated with detection of short THz pulses.
Address
Corporate Author Thesis
Publisher IOP Publishing Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Seliverstov_2016 Serial 1337
Permanent link to this record
 

 
Author (up) Tretyakov, I. V.; Finkel, M. I.; Ryabchun, S. A.; Kardakova, A. I.; Seliverstov, S. V.; Petrenko, D. V.; Goltsman, G. N.
Title Hot-electron bolometer mixers with in situ contacts Type Journal Article
Year 2014 Publication Radiophys. Quant. Electron. Abbreviated Journal Radiophys. Quant. Electron.
Volume 56 Issue 8-9 Pages 591-598
Keywords HEB mixers
Abstract We report on the latest achievements in the development of superconducting hot-electron bolometer (HEB) mixers for terahertz superheterodyne receivers. We consider application ranges of such receivers and requirements for the basic characteristics of the mixers. Main features of the mixers, such as noise temperature, gain bandwidth, noise bandwidth, and required local-oscillator power, have been improved significantly over the past few years due to intense research work, both in terms of the element fabrication quality and in terms of understanding of the physics of the processes occurring in the HEB mixers. Contacts between the superconducting bridge and the planar antenna play a key role in the mixer operation. Improvement of the quality of the contacts leads simultaneously to a decrease in the noise temperature and an increase in the gain bandwidth of a mixer.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0033-8443 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 1170
Permanent link to this record