Details
   web
Records
Author (up) Aksaev, E. E.; Gershenzon, E.M.; Gol'tsman, G. N.; Mirskij, G. I.; Semenov, A. D.
Title Submillimetric spectrometer-relaxometer based on backward-wave tubes with picosecond time resolution Type Journal Article
Year 1991 Publication Pribory i Tekhnika Eksperimenta Abbreviated Journal Pribory i Tekhnika Eksperimenta
Volume 34 Issue 2 Pages 125-131
Keywords BWO, applications
Abstract The high-sensitive automatic spectrometer-relaxometer based on backward-wave tubes in the range of 4÷0.25 mm was described permitting to study the response kinetics of sample under investigation in any point of this range with the resolution time of 10-11 s. The relaxation measurements were conducted using oscillation beats of two adequate tubes, the frequency of one of them was fixed, while that of the other one was changeable. The amplitude-frequency characteristic of the response under the conditions of synchronous reception was recorded at beat frequency variation from 107 to 1010 Hz. The high sensitivity was reached by decreasing the device recording band down to 100 Hz in the whole measuring range.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0032-8162 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 1683
Permanent link to this record
 

 
Author (up) Gershenzon, E. M.; Gol'tsman, G. N.; Mirskii, G. I.
Title Submillimeter backward-wave-tube spectrometer-relaxometer Type Journal Article
Year 1987 Publication Pribory i Tekhnika Eksperimenta Abbreviated Journal Pribory i Tekhnika Eksperimenta
Volume 30 Issue 4 Pages 131-137
Keywords BWO, applications
Abstract A backward-wave-tube (BWT) spectrometer-relaxometer is described that is designed for study of the relaxation characteristics of photoconductors in the wavelength range of 2-0.25 mm – in particular, to measure the relaxation times of the submillimeter photoconductivity of germanium in the range of 10[sup:-4]-10[sup:-9] sec and to determine from these data the concentration of compensating impurities of from 10[sup:10] to 10[sup:14] cm[sup:-3]. The instrument uses the beats of the oscillations of two BWTs and records the amplitude-frequency response of the specimen with variation of the beat frequency from 10[sup:4] to 10[sup:8] Hz with accumulation of the desired signal for less than or equal to1 sec by means of a quadrature synchronous detector. The beat frequency is stabilized and the quadrature voltages of the synchronous detector are formed by means of phase-locked loops.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Russian Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 1699
Permanent link to this record