Author (up) Archer, J. W. openurl 
  Title Multiple mixer, cryogenic receiver for 200-350 GHz Type Journal Article
  Year 1983 Publication Rev. Sci. Instrum. Abbreviated Journal Rev. Sci. Instrum.  
  Volume 54 Issue 10 Pages 1371-1376  
  Keywords Schottky, mixer, noise temperature  
  Abstract This paper describes a new 200–350-GHz dual polarization heterodyne radiometer receiver for radio astronomy applications. The receiver incorporates four pairs of cryogenically cooled Schottky-barrier diode single-ended mixers, each pair covering a 30–40-GHz subband of the full operating band. Each mixer, with its IF amplifier, is mounted in an individual cryogenic subdewar comprising a separate vcuum chamber and a cold stage, which may be readily thermally connected to or disconnected from the main refrigerator by a novel mechanical heat switch. A dual polarization LO diplexer is mounted on a rotary table above the subdewars. For band selection, the two diplexer rf output ports may be positioned over any of the four pairs of subdewars. The SSB receiver noise temperatues achieved are less than 500 K between 200 and 240 GHz, less than 800 K between 245 and 275 GHz and 1500 K at 345 GHz.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 589  
Permanent link to this record
 

 
Author (up) Fedorov, G.; Gayduchenko, I.; Titova, N.; Gazaliev, A.; Moskotin, M.; Kaurova, N.; Voronov, B.; Goltsman, G. url  doi
openurl 
  Title Carbon nanotube based schottky diodes as uncooled terahertz radiation detectors Type Journal Article
  Year 2018 Publication Phys. Status Solidi B Abbreviated Journal Phys. Status Solidi B  
  Volume 255 Issue 1 Pages 1700227 (1 to 6)  
  Keywords carbon nanotube schottky diodes, CNT  
  Abstract Despite the intensive development of the terahertz technologies in the last decade, there is still a shortage of efficient room‐temperature radiation detectors. Carbon nanotubes (CNTs) are considered as a very promising material possessing many of the features peculiar for graphene (suppression of backscattering, high mobility, etc.) combined with a bandgap in the carrier spectrum. In this paper, we investigate the possibility to incorporate individual CNTs into devices that are similar to Schottky diodes. The latter is currently used to detect radiation with a frequency up to 50 GHz. We report results obtained with semiconducting (bandgap of about 0.5 eV) and quasi‐metallic (bandgap of few meV) single‐walled carbon nanotubes (SWNTs). Semiconducting CNTs show better performance up to 300 GHz with responsivity up to 100 V W−1, while quasi‐metallic CNTs are shown to operate up to 2.5 THz.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0370-1972 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 1321  
Permanent link to this record
 

 
Author (up) Fedorov, G.; Gayduchenko, I.; Titova, N.; Moskotin, M.; Obraztsova, E.; Rybin, M.; Goltsman, G. url  doi
openurl 
  Title Graphene-based lateral Schottky diodes for detecting terahertz radiation Type Conference Article
  Year 2018 Publication Proc. Optical Sensing and Detection V Abbreviated Journal Proc. Optical Sensing and Detection V  
  Volume 10680 Issue Pages 30-39  
  Keywords graphene, terahertz radiation, detectors, Schottky diodes, carbon nanotubes, plasma waves  
  Abstract Demand for efficient terahertz radiation detectors resulted in intensive study of the carbon nanostructures as possible solution for that problem. In this work we investigate the response to sub-terahertz radiation of graphene field effect transistors of two configurations. The devices of the first type are based on single layer CVD graphene with asymmetric source and drain (vanadium and gold) contacts and operate as lateral Schottky diodes (LSD). The devices of the second type are made in so-called Dyakonov-Shur configuration in which the radiation is coupled through a spiral antenna to source and top electrodes. We show that at 300 K the LSD detector exhibit the room-temperature responsivity from R = 15 V/W at f= 129 GHz to R = 3 V/W at f = 450 GHz. The DS detector responsivity is markedly lower (2 V/W) and practically frequency independent in the investigated range. We find that at low temperatures (77K) the graphene lateral Schottky diodes responsivity rises with the increasing frequency of the incident sub-THz radiation. We interpret this result as a manifestation of a plasmonic effect in the devices with the relatively long plasmonic wavelengths. The obtained data allows for determination of the most promising directions of development of the technology of nanocarbon structures for the detection of THz radiation.  
  Address  
  Corporate Author Thesis  
  Publisher Spie Place of Publication Editor Berghmans, F.; Mignani, A.G.  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number 10.1117/12.2307020 Serial 1306  
Permanent link to this record
 

 
Author (up) Fetterman, H. R.; Tannenwald, P. E.; Clifton, B. J.; Parker, C. D.; Fitzgerald, W. D.; Erickson, N. R. openurl 
  Title Far-ir heterodyne radiometric measurements with quasioptical Schottky diode mixers Type Journal Article
  Year 1978 Publication Appl. Phys. Lett. Abbreviated Journal Appl. Phys. Lett.  
  Volume 33 Issue 2 Pages 151-154  
  Keywords Schottky  
  Abstract Frequency countings close to a phase locked zone in an electronic receiver show a 1/f power spectral density. The noise scaling versus the frequency deviation and the open loop gain are found from Adler's model of the phase locked loop. This fully agrees with experiments performed at 5 MHz on a receiver with a Schottky diode mixer and a low pass filter. The 1/f amplitude and frequency noise due to the whole set of (sub)harmonics is explained from a nonlinear mapping, with a coupling coefficient related to the structure of prime numbers.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 587  
Permanent link to this record
 

 
Author (up) Iomdina, E. N.; Goltsman, G. N.; Seliverstov, S. V.; Sianosyan, A. A.; Teplyakova, K. O.; Rusova, A. A. url  doi
openurl 
  Title Study of transmittance and reflectance spectra of the cornea and the sclera in the THz frequency range Type Journal Article
  Year 2016 Publication J. Biomed. Opt. Abbreviated Journal J. Biomed. Opt.  
  Volume 21 Issue 9 Pages 97002 (1 to 5)  
  Keywords BWO, IMPATT diode, Schottky diode, medicine, animals, cornea, physiology, humans, rabbits, sclera diagnostic imaging, physiology  
  Abstract An adequate water balance (hydration extent) is one of the basic factors of normal eye function, including its external shells: the cornea and the sclera. Adequate control of corneal and scleral hydration is very important for early diagnosis of a variety of eye diseases, stating indications for and contraindications against keratorefractive surgeries and the choice of contact lens correction solutions. THz systems of creating images in reflected beams are likely to become ideal instruments of noninvasive control of corneal and scleral hydration degrees. This paper reports on the results of a study involving transmittance and reflectance spectra for the cornea and the sclera of rabbit and human eyes, as well as those of the rabbit eye, in the frequency range of 0.13 to 0.32 THz. The dependence of the reflectance coefficient of these tissues on water mass percentage content was determined. The experiments were performed on three corneas, three rabbit scleras, two rabbit eyes, and three human scleras. The preliminary results demonstrate that the proposed technique, based on the use of a continuous THz radiation, may be utilized to create a device for noninvasive control of corneal and scleral hydration, which has clear potential of broad practical application.  
  Address Moscow State Pedagogical University, Department of Physics, 29 Malaya Pirogovskaya Street, Moscow 119435, Russia  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1083-3668 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:27626901 Approved no  
  Call Number Serial 1335  
Permanent link to this record