toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Divochiy, A.; Misiaszek, M.; Vakhtomin, Y.; Morozov, P.; Smirnov, K.; Zolotov, P.; Kolenderski, P. url  doi
openurl 
  Title Single photon detection system for visible and infrared spectrum range Type Journal Article
  Year 2018 Publication Opt. Lett. Abbreviated Journal Opt. Lett.  
  Volume 43 Issue 24 Pages (down) 6085-6088  
  Keywords  
  Abstract We demonstrate niobium nitride based superconducting single-photon detectors sensitive in the spectral range 452-2300 nm. The system performance was tested in a real-life experiment with correlated photons generated by means of spontaneous parametric downconversion, where one photon was in the visible range and the other was in the infrared range. We measured a signal to noise ratio as high as 4x10(4) in our detection setting. A photon detection efficiency as high as 64% at 1550 nm and 15% at 2300 nm was observed.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0146-9592 ISBN Medium  
  Area Expedition Conference  
  Notes https://arxiv.org/abs/1807.04273 Approved no  
  Call Number Serial 1227  
Permanent link to this record
 

 
Author Zhang, Zijing; Zhang, Jianlong; Wu, Long; Zhang, Yong; Zhao, Yuan; Su, Jianzhong doi  openurl
  Title Photon-counting chirped amplitude modulation lidar using a smart premixing method Type Journal Article
  Year 2013 Publication Opt. Lett. Abbreviated Journal Opt. Lett.  
  Volume 38 Issue 21 Pages (down) 4389-4392  
  Keywords photon-counting detector, lidar, Geiger mode APD, Geiger mode lidar  
  Abstract We proposed a new premixing method for photon-counting chirped amplitude modulation lidar (PCCAML). Earlier studies used the counting results of the returned signal detected by a Geiger mode avalanche photodiode detector (Gm-APD) to mix with the reference signal, called the postmixing method. We use an alternative method known as the premixing method, in which the reference signal is used to directly modulate the sampling gate width of the Gm-APD, and the mixing of the returned signal and the reference signal is completed before the Gm-APD. This premixing method is more flexible and may perform better than the postmixing method in terms of signal-to-noise ratio by cutting down a separated mixer commonly used in the postmixing lidar system. Furthermore, this premixing method lowers the demand for the sampling frequency of the Gm-APD. It allows the use of a much wider modulation bandwidth to improve the range accuracy and resolution. To the best of our knowledge, this is the first report to use the premixing method in the PCCAML system, which will benefit future lidar applications.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 1006  
Permanent link to this record
 

 
Author Lobanov, Yury; Shcherbatenko, Michael; Shurakov, Alexander; Rodin, Alexander V.; Klimchuk, Artem; Nadezhdinsky, Alexander I.; Maslennikov, Sergey; Larionov, Pavel; Finkel, Matvey; Semenov, Alexander; Verevkin, Aleksandr A.; Voronov, Boris M.; Ponurovsky, Yakov; Klapwijk, Teunis M.; Gol'tsman, Gregory N. url  doi
openurl 
  Title Heterodyne detection at near-infrared wavelengths with a superconducting NbN hot-electron bolometer mixer Type Journal Article
  Year 2014 Publication Opt. Lett. Abbreviated Journal  
  Volume 39 Issue 6 Pages (down) 1429-1432  
  Keywords HEB, zebra, IR, infrared  
  Abstract We report on the development of a highly sensitive optical receiver for heterodyne IR spectroscopy at the communication wavelength of 1.5 μm (200 THz) by use of a superconducting hot-electron bolometer. The results are important for the resolution of narrow spectral molecular lines in the near-IR range for the study of astronomical objects, as well as for quantum optical tomography and fiber-optic sensing. Receiver configuration as well as fiber-to-detector light coupling designs are discussed. Light absorption of the superconducting detectors was enhanced by nano-optical antennas, which were coupled to optical fibers. An intermediate frequency (IF) bandwidth of about 3 GHz was found in agreement with measurements at 300 GHz, and a noise figure of about 25 dB was obtained that was only 10 dB above the quantum limit.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 906  
Permanent link to this record
 

 
Author Morozov, P.; Lukina, M.; Shirmanova, M.; Divochiy, A.; Dudenkova, V.; Gol'tsman, G. N.; Becker, W.; Shcheslavskiy, V. I. url  doi
openurl 
  Title Singlet oxygen phosphorescence imaging by superconducting single-photon detector and time-correlated single-photon counting Type Journal Article
  Year 2021 Publication Opt. Lett. Abbreviated Journal Opt. Lett.  
  Volume 46 Issue 6 Pages (down) 1217-1220  
  Keywords SSPD, SNSPD, applications  
  Abstract This Letter presents, to the best of our knowledge, a novel optical configuration for direct time-resolved measurements of luminescence from singlet oxygen, both in solutions and from cultured cells on photodynamic therapy. The system is based on the superconducting single-photon detector, coupled to the confocal scanner that is modified for the near-infrared measurements. The recording of a phosphorescence signal from singlet oxygen at 1270 nm has been done using time-correlated single-photon counting. The performance of the system is verified by measuring phosphorescence from singlet oxygen generated by the photosensitizers commonly used in photodynamic therapy: methylene blue and chlorin e6. The described system can be easily upgraded to the configuration when both phosphorescence from singlet oxygen and fluorescence from the cells can be detected in the imaging mode. Thus, co-localization of the signal from singlet oxygen with the areas inside the cells can be done.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0146-9592 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:33720151 Approved no  
  Call Number Serial 1221  
Permanent link to this record
 

 
Author Kitaeva, G. K.; Kornienko, V. V.; Kuznetsov, K. A.; Pentin, I. V.; Smirnov, K. V.; Vakhtomin, Y. B. url  doi
openurl 
  Title Direct detection of the idler THz radiation generated by spontaneous parametric down-conversion Type Journal Article
  Year 2019 Publication Opt. Lett. Abbreviated Journal Opt. Lett.  
  Volume 44 Issue 5 Pages (down) 1198-1201  
  Keywords HEB applications  
  Abstract We study parametric down-conversion (PDC) of optical laser radiation in the strongly frequency non-degenerate regime which is promising for the generation of quantum-correlated pairs of extremely different spectral ranges, the optical and the terahertz (THz) ones. The possibility to detect tenuous THz-frequency photon fluxes generated under low-gain spontaneous PDC is demonstrated using a hot electron bolometer. Then experimental dependences of the THz radiation power on the detection angle and on the pump intensity are analyzed.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0146-9592 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:30821747 Approved no  
  Call Number Serial 1801  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: