|
Records |
Links |
|
Author |
Semenov, A. D.; Hübers, H.-W.; Gol’tsman, G. N.; Smirnov, K. |
|
|
Title |
Superconducting quantum detector for astronomy and X-ray spectroscopy |
Type |
Conference Article |
|
Year |
2002 |
Publication |
Proc. Int. Workshop on Supercond. Nano-Electronics Devices |
Abbreviated Journal |
Proc. Int. Workshop on Supercond. Nano-Electronics Devices |
|
|
Volume |
|
Issue |
|
Pages |
201-210 |
|
|
Keywords |
NbN SSPD, SNSPD, SQD, superconducting quantum detectors, X-ray spectroscopy |
|
|
Abstract |
We propose the novel concept of ultra-sensitive energy-dispersive superconducting quantum detectors prospective for applications in astronomy and X-ray spectroscopy. Depending on the superconducting material and operation conditions, such detector may allow realizing background limited noise equivalent power 10−21 W Hz−1/2 in the terahertz range when exposed to 4-K background radiation or counting of 6-keV photon with almost 10—4 energy resolution. Planar layout and relatively simple technology favor integration of elementary detectors into a detector array. |
|
|
Address |
Naples, Italy |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer |
Place of Publication |
Boston, MA |
Editor |
Pekola, J.; Ruggiero, B.; Silvestrini, P. |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
978-1-4615-0737-6 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
International Workshop on Superconducting Nano-Electronics Devices, May 28-June 1, 2001 |
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
semenov2002superconducting |
Serial |
1525 |
|
Permanent link to this record |
|
|
|
|
Author |
Kaurova, N. S.; Finkel, M. I.; Maslennikov, S. N.; Vahtomin, Yu. B.; Antipov, S. V.; Smirnov, K. V.; Voronov, B. M.; Gol'tsman, G. N.; Ilyin, K. S. |
|
|
Title |
Submillimeter mixer based on YBa2Cu3O7-x thin film |
Type |
Conference Article |
|
Year |
2004 |
Publication |
Proc. 1-st conf. Fundamental problems of high temperature superconductivity |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
291 |
|
|
Keywords |
HTS, HEB mixer |
|
|
Abstract |
|
|
|
Address |
Moscow-Zvenigorod |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Moscow-Zvenigorod |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
355 |
|
Permanent link to this record |
|
|
|
|
Author |
Ozhegov, R. V.; Smirnov, A. V.; Vakhtomin, Yu. B.; Smirnov, K. V.; Divochiy, A. V.; Goltsman, G. N. |
|
|
Title |
Ultrafast superconducting bolometer receivers for terahertz applications |
Type |
Abstract |
|
Year |
2009 |
Publication |
Proc. PIERS |
Abbreviated Journal |
Proc. PIERS |
|
|
Volume |
|
Issue |
|
Pages |
867 |
|
|
Keywords |
HEB |
|
|
Abstract |
The research by the group of Moscow State Pedagogical University into the hot-electron phenomena in thin superconducting films has led to the development of new types of detectors and their use both in fundamental and applied studies. In this paper, we present the results of testing the terahertz HEB receiver systems based on ultrathin (∼ 4 nm) NbN and MoRe detectors with a response time of 50 ps and 1 ns, respectively. We have developed three types of devices which differ in the way a terahertz signal is coupled to the detector and cover the following ranges: 0.3–3 THz, 0.1–30 THz and 25–70 THz. In the case of the receiving system optimized for 0.3–3 THz, the sensitive element (a strip of asuperconductor with planar dimensions of 0.2μm (length) by 1.7μm (width)) was integrated witha planar broadband log-spiral antenna. For additional focusing ofthe incident radiation a silicon hyperhemispherical lens was used. For the 0.1–30 THz receivingsystem, the sensitive element was patterned as parallel strips(2μm wide each) filling an area of 500×500μm2with a filling factor of 0.5. In the receivingsystem of this type we used direct coupling of the incident radiation to the sensitive element. Inthe 25–70 THz range (detector type 2/2a in Table 1) we used a square-shaped superconductingdetector with planar dimensions of 10×10μm2. Incident radiation was coupled to the detectorwith the use of a germanium hyperhemispherical lens.The response time of the above receiving systems is determined by the cooling rate of the hotelectrons in the film. That depends on the electron-phonon interaction time, which is less forultrathin NbN than in MoRe. |
|
|
Address |
Moscow, Russia |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
The Electromagnetics Academy |
Place of Publication |
777 Concord Avenue, Suite 207 Cambridge, MA 02138 |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1559-9450 |
ISBN |
978-1-934142-09-7 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
RPLAB @ sasha @ ozhegovultrafast |
Serial |
1022 |
|
Permanent link to this record |
|
|
|
|
Author |
Iomdina, E. N.; Goltsman, G. N.; Seliverstov, S. V.; Sianosyan, A. A.; Teplyakova, K. O.; Rusova, A. A. |
|
|
Title |
Study of transmittance and reflectance spectra of the cornea and the sclera in the THz frequency range |
Type |
Journal Article |
|
Year |
2016 |
Publication |
J. Biomed. Opt. |
Abbreviated Journal |
J. Biomed. Opt. |
|
|
Volume |
21 |
Issue |
9 |
Pages |
97002 (1 to 5) |
|
|
Keywords |
BWO, IMPATT diode, Schottky diode, medicine, animals, cornea, physiology, humans, rabbits, sclera diagnostic imaging, physiology |
|
|
Abstract |
An adequate water balance (hydration extent) is one of the basic factors of normal eye function, including its external shells: the cornea and the sclera. Adequate control of corneal and scleral hydration is very important for early diagnosis of a variety of eye diseases, stating indications for and contraindications against keratorefractive surgeries and the choice of contact lens correction solutions. THz systems of creating images in reflected beams are likely to become ideal instruments of noninvasive control of corneal and scleral hydration degrees. This paper reports on the results of a study involving transmittance and reflectance spectra for the cornea and the sclera of rabbit and human eyes, as well as those of the rabbit eye, in the frequency range of 0.13 to 0.32 THz. The dependence of the reflectance coefficient of these tissues on water mass percentage content was determined. The experiments were performed on three corneas, three rabbit scleras, two rabbit eyes, and three human scleras. The preliminary results demonstrate that the proposed technique, based on the use of a continuous THz radiation, may be utilized to create a device for noninvasive control of corneal and scleral hydration, which has clear potential of broad practical application. |
|
|
Address |
Moscow State Pedagogical University, Department of Physics, 29 Malaya Pirogovskaya Street, Moscow 119435, Russia |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1083-3668 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
PMID:27626901 |
Approved |
no |
|
|
Call Number |
|
Serial |
1335 |
|
Permanent link to this record |
|
|
|
|
Author |
Shurakov, Alexander; Tong, Edward; Blundell, Raymond; Gol'tsman, Gregory |
|
|
Title |
Microwave stabilization of HEB mixer by a microchip controller |
Type |
Conference Article |
|
Year |
2012 |
Publication |
IEEE MTT-S international microwave symposium digest |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
1-3 |
|
|
Keywords |
HEB mixer stability, microwave injection, Allan variance, Allan time |
|
|
Abstract |
The stability of a Hot Electron Bolometer (HEB) mixer can be improved by the use of microwave injection. In this article we report a refinement of this approach. We introduce a microchip controller to facilitate the implementation of the stabilization scheme, and demonstrate that the feedback loop effectively suppresses drifts in the HEB bias current, leading to an improvement in the receiver stability. The measured Allan time of the mixer's IF output power is increased to > 10 s. |
|
|
Address |
Montreal, QC, Canada |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
857 |
|
Permanent link to this record |