Details
   web
Records
Author Ekström, H.; Karasik, B.; Kollberg, E.; Gol'tsman, G.; Gershenzon, E.
Title 350 GHz NbN hot electron bolometer mixer Type Conference Article
Year 1995 Publication Proc. 6th Int. Symp. Space Terahertz Technol. Abbreviated Journal Proc. 6th Int. Symp. Space Terahertz Technol.
Volume Issue Pages 269-283
Keywords NbN HEB mixers
Abstract Superconducting NbN hot-electron bolometer (HEB) mixer devices have been fabricated and measured at 350 GHz. The HEB is integrated with a double dipole antenna on an extended crystalline quartz hyper hemispherical substrate lens. Heterodyne measurement gave a -3 dB bandwidth, mainly determined by the electron- phonon interaction time, of about 680 and 1000 MHz for two different films with Tc = 8.5 and 11 K respectively. The measured DSB receiver noise temperature is around 3000 K at 800 MHz IF frequency. The main contribution to the output noise from the device is due to electron temperature fluctuations with the equivalent output noise temperature TFL-100 K. TH, has the same frequency dependence as the IF response. The contribution from Johnson noise is of the order of T. The RF coupling loss is estimated to be = 6 dB. The film with lower Tc, had an estimated intrinsic low-frequency conversion loss = 7 dB, while the other film had a conversion loss as high as 14 dB. The difference in intrinsic conversion loss is explained by less uniform absorption of radiation. Measurements of the small signal impedance shows a transition of the output impedance from the DC differential resistance Rd=dV/dI in the low frequency limit to the DC resistance R 0 =Uoff 0 in the bias point for frequencies above 3 GHz. We judge that the optimum shape of the IV-characteristic is more easily obtained at THz frequencies where the main restriction in performance should come from problems with the RF coupling.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue (up) Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 1628
Permanent link to this record
 

 
Author Gerecht, E.; Musante, C. F.; Schuch, R.; Lutz, C. R.; Jr.; Yngvesson, K. S.; Mueller, E. R.; Waldivian, J.; Gol'tsman, G. N.; Voronov, B. M.; Gershenzon, E. M.
Title Hot electron detection and mixing experiments in NbN at 119 micrometer wavelength Type Conference Article
Year 1995 Publication Proc. 6th Int. Symp. Space Terahertz Technol. Abbreviated Journal Proc. 6th Int. Symp. Space Terahertz Technol.
Volume Issue Pages 284-293
Keywords NbN HEB mixers, detectors
Abstract We have performed preliminary experiments with the goal of demonstrating a Hot Electron Bolometric (HEB) mixer for a 119 micrometer wavelength (2.5 THz). We have chosen a NbN device of size 700 x 350 micrometers. This device can easily be coupled to a laser LO source, which is advantageous for performing a prototype experiment. The relatively large size of the device means that the LO power required is in the mW range; this power can be easily obtained from a THz laser source. We have measured the amount of laser power actually absorbed in the device, and from this have estimated the best optical coupling loss to be about 10 di . We are developing methods for improving the optical coupling further. Preliminary measurements of the response of the device to a chopped black-body have not yet resulted in a measured receiver noise temperature. We expect to be able to complete this measurement in the near future.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue (up) Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 1629
Permanent link to this record
 

 
Author Zorin, M.; Lindgren, M.; Danerud, M.; Karasik, B.; Winkler, D.; Gol'tsman, G.; Gershenzon, E.
Title Nonequilibrium and bolometric responses of YBaCuO thin films to high-frequency modulated laser radiation Type Journal Article
Year 1995 Publication J. Supercond. Abbreviated Journal J. Supercond.
Volume 8 Issue 1 Pages 11-15
Keywords YBCO HTS HEB
Abstract Picosecond nonequilibrium and slow bolometric responses to infrared radiation from a patterned high-T c superconducting (HTS) film in resistive and normal states deposited onto LaAlO3, NdGaO3, and MgO substrates were investigated using both pulse and modulation techniques. The response time of 35 ps to a laser pulse of 17 ps FWHM has been observed. The intrinsic response time of the fast process is expected to be about a few picoseconds. The modulation technique, being free from the disadvantages of pulse methods (poor sensitivity, limited dynamic range), makes the detailed study of a number of relaxation processes possible. Besides the nonequilibrium response, two kinds of bolometric processes, namely phonon transport through the film-substrate interface and phonon thermal diffusion in a substrate, manifest themselves in certain frequency dependences.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue (up) Edition
ISSN 0896-1107 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 1630
Permanent link to this record
 

 
Author Гольцман, Г. Н.; Веревкин, А. А.; Гершензон, Е. М.; Птицина, Н. Г.; Смирнов, К. В.; Чулкова, Г. М.
Title Исследования процессов неупругой релаксации и примесная спектроскопия-релаксометрия в двумерном электронном газе в полупроводниковых структурах с квантовыми ямами Type Report
Year 1995 Publication Abbreviated Journal
Volume Issue Pages
Keywords
Abstract В гетероструктурах GaAs/AlGaAs впервые прямым методом измерена температурная зависимость вpемени энеpгетической pелаксации двумерного электронного газа te(T) в широком диапазоне температур Т=1,5 – 50 К в квазиравновесных условиях. Для измерений использовался высокочувствительный спектрометр миллиметрового диапазона волн с высоким временным разрешением, который позволял измерять релаксационные времена до 150 пс с погрешностью не более 20%. Верхний предел температуры определялся временным разрешением спектрометра. Исследования проводились на высококачественных образцах с поверхностной концентрацией носителей ns = 4,2 1011 см-2 и подвижностью m = 7 105 см2В-1с-1 (при Т = 4,2К). В квазиравновесных условиях из температурной зависимости tе определен предел подвижности при низких температурах (T<4.2 K), связанный с рассеянием на пьезоакустическом потенциале, получено время неупругой релаксации, связанное с рассеянием на деформационном потенциале (15 K25 K), получено характерное время испускания оптического фонона (tLO>4,5пс), которое существенно превышает время сронтанного излучения оптического фонона (примерно в 30 раз), что связано с большой ролью процессов перепоглащения фононов электронами.При низких температурах проведены измерения tе в условиях сильного разогрева. Полученные значения tе и зависимость tе от температуры электронов Те совпадают с tе(Т) в квазиравновесных условиях при Т=Те. Из полученных значений tе(Те) построена зависимость мощности энергетических потерь от Те, которая хорошо согласуется с литературными данными.Начаты измерения в магнитном поле, которые показывают переспективность использованного нами метода измерений как в области слабых магнитных полей при факторе заполнения >10, так и в области сильных магнитных полей при факторе заполнения >1-2.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue (up) Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Отчет о НИР/НИОКР; РФФИ: 95-02-06409-а; Approved no
Call Number Serial 1831
Permanent link to this record