Details
   web
Records
Author Floet D. W.; Gao J. R.; Klapwijk T. M.; de Korte P. A. J.
Title Bias Dependence of the Thermal Time Constant in Nb Superconducting Diffusion-Cooled HEB Mixers Type Journal Article
Year 2000 Publication Appl. Phys. Lett. Abbreviated Journal Appl. Phys. Lett.
Volume 77 Issue Pages (down) 1719
Keywords
Abstract We present an experimental study of the intermediate frequency bandwidth of a Nb diffusion-cooled hot-electron bolometer mixer for different bias voltages. The measurements show that the bandwidth increases with increasing voltage. Analysis of the data reveals that this effect is mainly caused by a decrease of the intrinsic thermal time of the mixer and that the effect of electrothermal feedback through the intermediate frequency circuit is small. The results are understood using a qualitative model, which takes into account the different effective diffusion constants in the normal and superconducting domains.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number RPLAB @ atomics90 @ Serial 971
Permanent link to this record
 

 
Author Manus, M. K. Mc; Kash, J. A.; Steen, S. E.; Polonsky, S.; Tsang, J.C.; Knebel, D. R.; Huott, W.
Title PICA: Backside failure analysis of CMOS circuits using picosecond imaging circuit analysis Type Journal Article
Year 2000 Publication Microelectronics Reliability Abbreviated Journal Microelectronics Reliability
Volume 40 Issue Pages (down) 1353-1358
Keywords SSPD, CMOS testing
Abstract Normal operation of complementary metal-oxide semiconductor (CMOS) devices entails the emission of picosecond pulses of light, which can be used to diagnose circuit problems. The pulses that are observed from submicron sized field effect transistors (FETs) are synchronous with logic state switching. Picosecond Imaging Circuit Analysis (PICA), a new optical imaging technique combining imaging with timing, spatially resolves individual devices at the 0.5 micron level and switching events on a 10 picosecond timescale. PICA is used here for the diagnostics of failures on two VLSI microprocessors.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 1054
Permanent link to this record
 

 
Author Gerecht, E.; Musante, C.F.; Zhuang, Y.; Ji, M.; Yngvesson, K.S.; Goyette, T.; Waldman, J.
Title NbN hot electron bolometric mixer with intrinsic receiver noise temperature of less than five times the quantum noise limit Type Conference Article
Year 2000 Publication Proc. IMS Abbreviated Journal
Volume 2 Issue Pages (down) 1007-1010
Keywords HEB mixer
Abstract In recent years, improvements in device development and quasi-optical coupling techniques utilizing planar antennas have led to a significant achievement in low noise receivers for the edges of the submillimeter frequency regime. Hot electron bolometric (HEB) receivers made of thin superconducting films such as NbN have produced a viable option for instruments designed to measure the molecular spectra for astronomical applications as well as in remote sensing of the atmosphere in the THz regime. This paper describes an NbN HEB mixer with intrinsic DSB receiver noise temperature of at most five times the quantum noise limit at frequencies as high as 2.24 THz
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 477
Permanent link to this record
 

 
Author Kawamura, Jonathan; Blundell, Raymond; Tong, C.-Y. Edward; Papa, D. Cosmo; Hunter, Todd R.; Paine, Scot.t. N.; Patt, Ferdinand; Gol'tsman, Gregory; Cherednichenko, Sergei; Voronov, Boris; Gershenzon, Eugene
Title Superconductive hot-electron bolometer mixer receiver for 800 GHz operation Type Miscellaneous
Year 2000 Publication IEEE Trans. Microwave Theory and Techniques Abbreviated Journal IEEE Trans. Microwave Theory and Techniques
Volume 48 Issue 4 Pages (down) 683-689
Keywords
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number RPLAB @ s @ Kawamura_superconductivehot-electron Serial 424
Permanent link to this record
 

 
Author Kawamura, J.; Blundell, R.; Tong, C.-Y. E.; Papa, D. C.; Hunter, T. R.; Paine, S. N.; Patt, F.; Gol'tsman, G.; Cherednichenko, S.; Voronov, B.; Gershenzon, E.
Title Superconductive hot-electron-bolometer mixer receiver for 800-GHz operation Type Journal Article
Year 2000 Publication IEEE Trans. Microw. Theory Techn. Abbreviated Journal IEEE Trans. Microw. Theory Techn.
Volume 48 Issue 4 Pages (down) 683-689
Keywords NbN HEB mixers, LO power, local oscillator power, saturation, linearity, dynamic range
Abstract In this paper, we describe a superconductive hot-electron-bolometer mixer receiver designed to operate in the partially transmissive 350-μm atmospheric window. The receiver employs an NbN thin-film microbridge as the mixer element, in which the main cooling mechanism of the hot electrons is through electron-phonon interaction. At a local-oscillator frequency of 808 GHz, the measured double-sideband receiver noise temperature is TRX=970 K, across a 1-GHz intermediate-frequency bandwidth centered at 1.8 GHz. We have measured the linearity of the receiver and the amount of local-oscillator power incident on the mixer for optimal operation, which is PLO≈1 μW. This receiver was used in making observations as a facility instrument at the Heinrich Hertz Telescope, Mt. Graham, AZ, during the 1998-1999 winter observing season.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0018-9480 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number RPLAB @ lobanovyury @ Serial 573
Permanent link to this record