|
Records |
Links |
|
Author |
Hu, Xiaolong; Zhong, Tian; White, James E.; Dauler, Eric A. Najafi, Faraz; Herder, Charles H.; Wong, Franco N. C.; Berggren, Karl K. |
|
|
Title |
Fiber-coupled nanowire photon counter at 1550 nm with 24% system detection efficiency |
Type |
Journal Article |
|
Year |
2009 |
Publication |
Optics Letters |
Abbreviated Journal |
Opt. Lett. |
|
|
Volume |
34 |
Issue |
23 |
Pages |
3607-3609 |
|
|
Keywords |
SNSPD |
|
|
Abstract |
We developed a fiber-coupled superconducting nanowire single-photon detector system in a close-cycled cryocooler and achieved 24% and 22% system detection efficiencies at wavelengths of 1550 and 1315 nm, respectively. The maximum dark count rate was ~1000 counts/s. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
RPLAB @ gujma @ |
Serial |
679 |
|
Permanent link to this record |
|
|
|
|
Author |
Kerman, Andrew J.; Yang, Joel K. W.; Molnar, Richard J.; Dauler, Eric A.; Berggren, Karl K. |
|
|
Title |
Electrothermal feedback in superconducting nanowire single-photon detectors |
Type |
Journal Article |
|
Year |
2009 |
Publication |
Phys. Rev. B |
Abbreviated Journal |
Phys. Rev. B |
|
|
Volume |
79 |
Issue |
10 |
Pages |
4 |
|
|
Keywords |
SNSPD |
|
|
Abstract |
We investigate the role of electrothermal feedback in the operation of superconducting nanowire single-photon detectors (SNSPDs). It is found that the desired mode of operation for SNSPDs is only achieved if this feedback is unstable, which happens naturally through the slow electrical response associated with their relatively large kinetic inductance. If this response is sped up in an effort to increase the device count rate, the electrothermal feedback becomes stable and results in an effect known as latching, where the device is locked in a resistive state and can no longer detect photons. We present a set of experiments which elucidate this effect and a simple model which quantitatively explains the results. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
RPLAB @ gujma @ |
Serial |
680 |
|
Permanent link to this record |
|
|
|
|
Author |
Yates, S. J. C.; Baryshev, A. M.; Baselmans, J. J. A.; Klein, B.; Güsten, R. |
|
|
Title |
Fast Fourier transform spectrometer readout for large arrays of microwave kinetic inductance detectors |
Type |
Journal Article |
|
Year |
2009 |
Publication |
Applied Physics Letters |
Abbreviated Journal |
Appl. Phys. Lett. |
|
|
Volume |
95 |
Issue |
4 |
Pages |
3 |
|
|
Keywords |
|
|
|
Abstract |
Microwave kinetic inductance detectors have great potential for large, very sensitive detector arrays for use in, for example, submillimeter imaging. Being intrinsically readout in the frequency domain, they are particularly suited for frequency domain multiplexing allowing ~1000 s of devices to be readout with one pair of coaxial cables. However, this moves the complexity of the detector from the cryogenics to the warm electronics. We present here the concept and experimental demonstration of the use of fast Fourier transform spectrometer readout, showing no deterioration of the noise performance compared to the low noise analog mixing while allowing high multiplexing ratios. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
RPLAB @ gujma @ |
Serial |
697 |
|
Permanent link to this record |
|
|
|
|
Author |
Minaeva, Olga; Bonato, Cristian; Saleh, Bahaa E. A.; Simon, David S.; Sergienko, Alexander V. |
|
|
Title |
Odd- and even-order dispersion cancellation in quantum interferometry |
Type |
Journal Article |
|
Year |
2009 |
Publication |
Phys. Rev. Lett. |
Abbreviated Journal |
Phys. Rev. Lett. |
|
|
Volume |
102 |
Issue |
10 |
Pages |
4 |
|
|
Keywords |
|
|
|
Abstract |
We describe a novel effect involving odd-order dispersion cancellation. We demonstrate that odd- and even-order dispersion cancellation may be obtained in different regions of a single quantum interferogram using frequency-anticorrelated entangled photons and a new type of quantum interferometer. This offers new opportunities for quantum communication and metrology in dispersive media. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
RPLAB @ gujma @ |
Serial |
699 |
|
Permanent link to this record |
|
|
|
|
Author |
Dauler, Eric; Kerman, Andrew; Robinson, Bryan; Yang, Joel; Voronov, Boris; Goltsman, Gregory; Hamilton, Scott; Berggren, Karl |
|
|
Title |
Photon-number-resolution with sub-30-ps timing using multi-element superconducting nanowire single photon detectors |
Type |
Journal Article |
|
Year |
2009 |
Publication |
J. Modern Opt. |
Abbreviated Journal |
J. Modern Opt. |
|
|
Volume |
56 |
Issue |
2 |
Pages |
364-373 |
|
|
Keywords |
PNR SSPD; SNSPD; photon-number-resolution; superconducting nanowire single photon detector; timing jitter; system detection efficiency |
|
|
Abstract |
A photon-number-resolving detector based on a four-element superconducting nanowire single photon detector is demonstrated to have sub-30-ps resolution in measuring the arrival time of individual photons. This detector can be used to characterize the photon statistics of non-pulsed light sources and to mitigate dead-time effects in high-speed photon counting applications. Furthermore, a 25% system detection efficiency at 1550 nm was demonstrated, making the detector useful for both low-flux source characterization and high-speed photon-counting and quantum communication applications. The design, fabrication and testing of this detector are described, and a comparison between the measured and theoretical performance is presented. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
RPLAB @ gujma @ |
Serial |
700 |
|
Permanent link to this record |