|   | 
Details
   web
Records
Author Smirnov, A.; Golubev, E.; Arkhipov, M.; Filina, E.; Pyshnov, V.; Myshonkova, N.; Fedorchuk, S.; Kosmovich, T.; Vinogradov, I.; Baryshev, A.; de Graauw, Th.; Likhachev, S.; Kardashev, N.
Title Millimetron Space Observatory: progress in the development of payload module Type Conference Article
Year 2019 Publication Proc. 30th Int. Symp. Space Terahertz Technol. Abbreviated Journal Proc. 30th Int. Symp. Space Terahertz Technol.
Volume Issue Pages 180-181
Keywords (down) Millimetron space observatory, primary mirror
Abstract Millimetron Space Observatory (MSO) is mission addressed to creation a space cryogenic telescope with aperture about 10-m [1]. Such telescope will allow scientific community to have an astronomical instrument with enormous sensitivity and angular resolution in the submillimeter and far-infrared wavelength ranges. We plan to install at the telescope several FIR and sub-millimeter scientific instruments, which will enable high-resolution imaging and spectroscopy observations with unprecedented sensitivity. At the same time, MSO will enable observations with an extremely high angular resolution (up to 0.1×10 -6 arcsec) as an element of a ground-space very long baseline interferometry system (S-VLBI). Thereby the observatory will contribute breakthrough capability into solution a number of cosmology and fundamental astrophysics questions about the origin and evolution of our Universe, galaxies, stars and other objects [2]. The MSO is divided into two parts: the payload module and the bus module. Due to the complexity of the payload module, most of the recent years of work are focused on it. This module includes an antenna of the telescope, scientific receivers, functional and service systems and a high-gain radio system for transmitting scientific data to Earth. The primary mirror of the telescope will be deployable and consist from of a 3-m aperture central part surrounded by 24 deployable petals. The concept of petals deployment is based on the successfully launched and currently working Radioastron project [3]. The surface accuracy of the deployable 10-m primary mirror of Radioastron achieves about 1 mm in space conditions. The telescope of MSO would have much better surface accuracy – less than 10 μm (rms). In order to achieve this we plan to use an active surface control system based on a wave front sensing. This system will be periodically employed to correct inaccuracies in the positions of the panels caused by different factors. A combination of a high modulus carbon fiber reinforced plastic (CFRP) and a cyanate ester resin as a binder provides a lightweight structure with low moisture absorption, high thermal stability and high stiffness. This combination has been chosen for the material of the primary mirror of telescope and many parts of it. The panels are mounted on the back support structure (Fig. 1) made from CFRP via precision cryogenic actuators. To achieve the required sensitivity of the telescope in the submm/FIR we need to cool antenna down to the temperature less than 10K (goal). It may be possible to do this on-orbit only by a combination of effective radiation cooling and additional active mechanical cooling. A cold space antenna requires minimization and stability of external thermal radiation. This is one of the reasons why MSO will be placed into orbit around the second Earth-Sun Lagrange point (L2). The MSO antenna into L2 will be cooled passively to a temperature about 30 – 60K by a suite of the deployable multi-layer V-groove shields. The following steps to reduce the temperature of the antenna are based on active reducing the thermal loads applied to it. Active mechanical cooling is based on existing close cycling space mechanical coolers. In this work, we will focus on the progress in the development of payload module.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 1280
Permanent link to this record
 

 
Author Tiulina, V.; Iomdina, E.; Goltsman, G.; Seliverstov, S.; Sianosyan, A.; Teplyakova, K.; Rusova, A.; Zaitsev, S.; Zernii, E.; Senin, I.
Title UVB promotes the initiation of uveitic inflammatory and changes in thehydration of the cornea in vivo Type Miscellaneous
Year 2019 Publication FEBS Open Bio Abbreviated Journal FEBS Open Bio
Volume 9 Issue S1 Pages 79
Keywords (down) medicine; scheimpflug imaging; UVB; confocal microscopy; cornea; optical coherent tomography; rabbit eyes; terahertz radiation
Abstract Recently, active research has been conducted in the field of terahertz (THz) scanning of human tissues for non­invasive determination of their hydration level, which haves hown high diagnostic efficiency of this technology in various pathological conditions. Recently, we have developed a laboratory model of the facility for monitoring the state of the water balance of the cornea using THz scanning in vivo, which opens up the possibility of applying this approach in ophthalmology. The aim of the work wasto compare the results of the THz scan of the cornea with its clinical changes using the example of an experimental model of the UV­ induced keratouveitis. Anexperimental study, which included a comprehensive assessment of clinical changes in the cornea of rabbits during keratouveitis induction, revealed a decrease in the stability of the tear film, pathological changes in the corneal epithelium and stroma, as well as its anatomical and optical parameters. Comparison of data obtained in the THz scan of the cornea with tears production, optical coherence tomography and confocal microscopy showed their consistency in all observation periods, which allows us to conclude that the developed laboratory setup works and the feasibility of further research to promote the corneal hydration evaluation technology in clinical practice. Acknowledgements: Research was funded by the RSF, grant number 16­15­00255.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 2211-5463 ISBN Medium
Area Expedition Conference
Notes Poster P-01-040 Approved no
Call Number Serial 1276
Permanent link to this record
 

 
Author Елезов, М. С.; Щербатенко, М. Л.; Сыч, Д. В.; Гольцман, Г. Н.
Title Практические особенности работы оптоволоконного квантового приемника Кеннеди Type Conference Article
Year 2019 Publication Proc. IWQO Abbreviated Journal Proc. IWQO
Volume Issue Pages 303-305
Keywords (down) Kennedy quantum receiver, fiber, quantum optics, standard quantum limit, superconducting nanowire single-photon detector, coherent detection
Abstract Мы рассматриваем практические особенности работы квантового приемника на основе схемы Кеннеди, собранного из стандартных оптоволоконных элементов и сверхпроводникового детектора одиночных фотонов. Приемник разработан для различения двух фазовомодулированных когерентных состояний света на длине волны 1,5 микрона в непрерывном режиме с частотой модуляции 200 КГц и уровнем ошибок различения примерно в два раза ниже стандартного квантового предела.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Russian Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Duplicated as 1288 Approved no
Call Number Serial 1283
Permanent link to this record
 

 
Author Проходцов, А. И.; Голиков, А. Д.; Ан, П. П.; Ковалюк, В. В.; Гольцман, Г. Н.
Title Влияние покрытия из оксида кремния на эффективность фокусирующего решеточного элемента связи из нитрида кремния Type Conference Article
Year 2019 Publication Proc. IWQO Abbreviated Journal Proc. IWQO
Volume Issue Pages 201-203
Keywords (down) integrated optics, silicon nitride, focusing grating coupler
Abstract В работе экспериментально изучена зависимость эффективности фокусирующего решеточного элемента связи от периода и фактора заполнения до и после напыления верхнего слоя из оксида кремния. Полученные данные имеют практическое значение при создании перестраиваемых интегрально-оптических устройств на нитриде кремния.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Russian Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Duplicated as 1188 Approved no
Call Number Serial 1282
Permanent link to this record
 

 
Author Kitaeva, G. K.; Kornienko, V. V.; Kuznetsov, K. A.; Pentin, I. V.; Smirnov, K. V.; Vakhtomin, Y. B.
Title Direct detection of the idler THz radiation generated by spontaneous parametric down-conversion Type Journal Article
Year 2019 Publication Opt. Lett. Abbreviated Journal Opt. Lett.
Volume 44 Issue 5 Pages 1198-1201
Keywords (down) HEB applications
Abstract We study parametric down-conversion (PDC) of optical laser radiation in the strongly frequency non-degenerate regime which is promising for the generation of quantum-correlated pairs of extremely different spectral ranges, the optical and the terahertz (THz) ones. The possibility to detect tenuous THz-frequency photon fluxes generated under low-gain spontaneous PDC is demonstrated using a hot electron bolometer. Then experimental dependences of the THz radiation power on the detection angle and on the pump intensity are analyzed.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0146-9592 ISBN Medium
Area Expedition Conference
Notes PMID:30821747 Approved no
Call Number Serial 1801
Permanent link to this record