Kovalyuk, V., Kahl, O., Ferrari, S., Vetter, A., Lewes-Malandrakis, G., Nebel, C., et al. (2018). On-chip single-photon spectrometer for visible and infrared wavelength range. In J. Phys.: Conf. Ser. (Vol. 1124, 051045).
Abstract: Here we show our latest progress in the field of a single-photon spectrometer for the visible and infrared wavelengths ranges implementation. We consider three different on-chip approaches: a coherent spectrometer with a low power of the heterodyne, a coherent spectrometer with a high power of the heterodyne, and an eight-channel single-photon spectrometer for direct detection. Along with high efficiency, spectrometers show high detection efficiency and temporal resolution through the use of waveguide integrated superconducting nanowire single-photon detectors.
|
|
|
Korneev, A., Kovalyuk, V., An, P., Golikov, A., Zubkova, E., Ferrari, S., et al. (2018). Superconducting single-photon detector for integrated waveguide spectrometer. In EPJ Web Conf. (Vol. 190, 04009).
Abstract: We present our recent achievements in the development of an on-chip spectrometer consisting of arrayed waveguide grating made of Si3N4 waveguides and NbN superconducting single-photon detector.
|
|
|
Zubkova, E., Golikov, A., An, P., Kovalyuk, V., Korneev, A., Ferrari, S., et al. (2019). CWDM demultiplexer using anti-reflection, contra-directional couplers based on silicon nitride rib waveguide. In J. Phys.: Conf. Ser. (Vol. 1410, 012179).
Abstract: We report on the development and fabrication of a 9-channel coarse wavelength-division multiplexing for telecommunication wavelengths (1550 nm) using anti-reflection contra-directional couplers, based on silicon nitride (Si3N4) rib waveguide. The transmitted and reflected spectrum in each channel of the demultiplexer were measured. The average full width at half maximum of the transmitted (reflected) spectra is about 3 nm.
|
|
|
Kuzin, A., Kovalyuk, V., Golikov, A., Prokhodtsov, A., Marakhin, A., Ferrari, S., et al. (2019). Efficiency of focusing grating couplers versus taper length and angle. In J. Phys.: Conf. Ser. (Vol. 1410, 012181).
Abstract: Here we experimentally studied dependence of a focusing grating coupler efficiency versus taper length and angle on silicon nitride platform. As a result, we obtained a dependence for the efficiency of a focusing grating coupler on the parameters of the taper length and angle.
|
|
|
Ferrari, S., Kovalyuk, V., Vetter, A., Lee, C., Rockstuhl, C., Semenov, A., et al. (2019). Analysis of the detection response of waveguide-integrated superconducting nanowire single-photon detectors at high count rate. Appl. Phys. Lett., 115(10), 101104.
Abstract: Nanophotonic circuitry and superconducting nanowires have been successfully combined for detecting single photons, propagating in an integrated photonic circuit, with high efficiency and low noise and timing uncertainty. Waveguide-integrated superconducting nanowire single-photon detectors (SNSPDs) can nowadays be engineered to achieve subnanosecond recovery times and can potentially be adopted for applications requiring Gcps count rates. However, particular attention shall be paid to such an extreme count rate regime since artifacts in the detector functionality emerge. In particular, a count-rate dependent detection efficiency has been encountered that can compromise the accuracy of quantum detector tomography experiments. Here, we investigate the response of waveguide-integrated SNSPDs at high photon flux and identify the presence of parasitic currents due to the accumulation of charge in the readout electronics to cause the above-mentioned artifact in the detection efficiency. Our approach allows us to determine the maximum photon count rate at which the detector can be operated without adverse effects. Our findings are particularly important to avoid artifacts when applying SNSPDs for quantum tomography.
We acknowledge support through ERC Consolidator Grant No. 724707 and from the Deutsche Forschungsgemeinschaft through Project No. PE 1832/5-1,2, as well as funding by the Volkswagen Foundation. This project has received funding from the European Union's Horizon 2020 research and innovation program under the Marie Skłodowska-Curie Grant Agreement No. 675745. V.K. and G.G. acknowledge support from the Russian Science Foundation Project No. 16-12-00045 (NbN film deposition and testing). A.V. acknowledges support from the Karlsruhe School of Optics and Photonics (KSOP).
|
|