Iomdina, E. N., Goltsman, G. N., Seliverstov, S. V., Sianosyan, A. A., Teplyakova, K. O., & Rusova, A. A. (2016). Study of transmittance and reflectance spectra of the cornea and the sclera in the THz frequency range. J. Biomed. Opt., 21(9), 97002 (1 to 5).
Abstract: An adequate water balance (hydration extent) is one of the basic factors of normal eye function, including its external shells: the cornea and the sclera. Adequate control of corneal and scleral hydration is very important for early diagnosis of a variety of eye diseases, stating indications for and contraindications against keratorefractive surgeries and the choice of contact lens correction solutions. THz systems of creating images in reflected beams are likely to become ideal instruments of noninvasive control of corneal and scleral hydration degrees. This paper reports on the results of a study involving transmittance and reflectance spectra for the cornea and the sclera of rabbit and human eyes, as well as those of the rabbit eye, in the frequency range of 0.13 to 0.32 THz. The dependence of the reflectance coefficient of these tissues on water mass percentage content was determined. The experiments were performed on three corneas, three rabbit scleras, two rabbit eyes, and three human scleras. The preliminary results demonstrate that the proposed technique, based on the use of a continuous THz radiation, may be utilized to create a device for noninvasive control of corneal and scleral hydration, which has clear potential of broad practical application.
Keywords: BWO, IMPATT diode, Schottky diode, medicine, animals, cornea, physiology, humans, rabbits, sclera diagnostic imaging, physiology
|
Elmanova, A., An, P., Kovalyuk, V., Golikov, A., Elmanov, I., & Goltsman, G. (2020). Study of silicon nitride O-ring resonator for gas-sensing applications. In J. Phys.: Conf. Ser. (Vol. 1695, 012124).
Abstract: In this work, we experimentally studied the influence of different gaseous surroundings on silicon nitride O-ring resonator transmission. We compared the obtained results with numerical calculations and theoretical analysis and found a good agreement between them. Our results have a great potential for gas sensing applications, where a compact footprint and high efficiency are desired simultaneously.
|
Venediktov, I. O., Elezov, M. S., Prokhodtsov, A. I., Kovalyuk, V. V., An, P. P., Golikov, A. D., et al. (2020). Study of microheater’s phase modulation for on-chip Kennedy receiver. In J. Phys.: Conf. Ser. (Vol. 1695, 012117).
Abstract: In this work we describe phase modulators for several Mach-Zehnder interferometers (MZI) on silicon nitride platform for telecomm wavelength (1550 nm). We obtained current-voltage and phase-voltage curves for these modulators. MZI are needed for experimental realisation of various quantum receivers that can distinguish weak coherent states of light with extremely low error. Thermo-optical (TO) modulation is ensured by microheaters on one of the arms of MZI, which enables the change of the refractive index of the material with temperature. This approach allows to apply the necessary voltage to the golden microheaters to obtain the required phase change. For the on-chip microheaters we demonstrate the dependence of the phase shift on the voltage applied to our on-chip microheaters.
|
Baksheeva, K., Vdovydchenko, A., Gorshkov, K., Ozhegov, R., Kinev, N., Koshelets, V., et al. (2019). Study of human skin radiation in the terahertz frequency range. In J. Phys.: Conf. Ser. (Vol. 1410, 012076 (1 to 5)).
Abstract: The radiation of human skin in the terahertz frequency range under the influence of mental stresses has been studied in the current work. An experimental setup for observation of changes in human skin radiation, which occur under the influence of psychological stresses, by means of a superconducting integrated receiver has been developed. More than 30 volunteers participate in these studies, which allows us to verify presence of correlation between the signals from the superconducting integrated terahertz receiver and other sensors that monitor human mental stress.
|
Kahl, O., Ferrari, S., Kovalyuk, V., Vetter, A., Lewes-Malandrakis, G., Nebel, C., et al. (2016). Spectrally resolved single-photon imaging with hybrid superconducting – nanophotonic circuits. arXiv:1609.07857v1 [physics.ins-det].
Abstract: The detection of individual photons is an inherently binary mechanism, revealing either their absence or presence while concealing their spectral information. For multi-color imaging techniques, such as single photon spectroscopy, fluorescence resonance energy transfer microscopy and fluorescence correlation spectroscopy, wavelength discrimination is essential and mandates spectral separation prior to detection. Here, we adopt an approach borrowed from quantum photonic integration to realize a compact and scalable waveguide-integrated single-photon spectrometer capable of parallel detection on multiple wavelength channels, with temporal resolution below 50 ps and dark count rates below 10 Hz. We demonstrate multi-detector devices for telecommunication and visible wavelengths and showcase their performance by imaging silicon vacancy color centers in diamond nanoclusters. The fully integrated hybrid superconducting-nanophotonic circuits enable simultaneous spectroscopy and lifetime mapping for correlative imaging and provide the ingredients for quantum wavelength division multiplexing on a chip.
|