|
Shurakov, A., Mikhailov, D., Belikov, I., Kaurova, N., Zilberley, T., Prikhodko, A., et al. (2020). Planar Schottky diode with a Γ-shaped anode suspended bridge. In J. Phys.: Conf. Ser. (Vol. 1695, 012154).
Abstract: In this paper we report on the fabrication of a planar Schottky diode utilizing a Г-shaped anode suspended bridge. The bridge maintains transition between the top and bottom level planes of a 1.4 µm thick GaAs mesa. To implement the profile of a suspended bridge and inward tilt of a mesa wall adjacent to it, we make use of an anisotropic etching of gallium arsenide. The geometry proposed enables the fabrication of a diode with mesa of an arbitrary thickness to mitigate AC losses in the diode layered structure at terahertz frequencies of interest. For frequencies beyond 1 THz, it is also beneficial to use the geometry for the implementation of n-GaAs/n-InGaAs heterojunction Schottky diodes grown on InP substrate.
|
|
|
Gayduchenko, I. A., Fedorov, G. E., Stepanova, T. S., Titova, N., Voronov, B. M., But, D., et al. (2016). Asymmetric devices based on carbon nanotubes as detectors of sub-THz radiation. In J. Phys.: Conf. Ser. (Vol. 741, 012143 (1 to 6)).
Abstract: Demand for efficient terahertz (THz) radiation detectors resulted in intensive study of the asymmetric carbon nanostructures as a possible solution for that problem. In this work, we systematically investigate the response of asymmetric carbon nanodevices to sub-terahertz radiation using different sensing elements: from dense carbon nanotube (CNT) network to individual CNT. We conclude that the detectors based on individual CNTs both semiconducting and quasi-metallic demonstrate much stronger response in sub-THz region than detectors based on disordered CNT networks at room temperature. We also demonstrate the possibility of using asymmetric detectors based on CNT for imaging in the THz range at room temperature. Further optimization of the device configuration may result in appearance of novel terahertz radiation detectors.
|
|
|
Florya, I. N., Korneeva, Y. P., Sidorova, M. V., Golikov, A. D., Gaiduchenko, I. A., Fedorov, G. E., et al. (2015). Energy relaxtation and hot spot formation in superconducting single photon detectors SSPDs. In EPJ Web of Conferences (Vol. 103, 10004 (1 to 2)).
Abstract: We have studied the mechanism of energy relaxation and resistive state formation after absorption of a single photon for different wavelengths and materials of single photon detectors. Our results are in good agreement with the hot spot model.
|
|
|
Fedorov, G. E., Gaiduchenko, I. A., Golikov, A. D., Rybin, M. G., Obraztsova, E. D., Voronov, B. M., et al. (2015). Response of graphene based gated nanodevices exposed to THz radiation. In EPJ Web of Conferences (Vol. 103, 10003 (1 to 2)).
Abstract: In this work we report on the response of asymmetric graphene based devices to subterahertz and terahertz radiation. Our devices are made in a configuration of a field-effect transistor with conduction channel between the source and drain electrodes formed with a CVD-grown graphene. The radiation is coupled through a spiral antenna to source and top gate electrodes. Room temperature responsivity of our devices is close to the values that are attractive for commercial applications. Further optimization of the device configuration may result in appearance of novel terahertz radiation detectors.
|
|
|
Semenov, A. D., Hübers, H. - W., Schubert, J., Gol'tsman, G. N., Elantiev, A. I., Voronov, B. M., et al. (2000). Design and performance of the lattice-cooled hot-electron terahertz mixer. J. Appl. Phys., 88(11), 6758–6767.
Abstract: We present the measurements and the theoreticalmodel of the frequency-dependent noise temperature of a superconductor lattice-cooled hot-electron bolometer mixer in the terahertz frequency range. The increase of the noise temperature with frequency is a cumulative effect of the nonuniform distribution of the high-frequency current in the bolometer and the charge imbalance, which occurs at the edges of the normal domain and at the contacts with normal metal. We show that under optimal operation the fluctuation sensitivity of the mixer is determined by thermodynamic fluctuations of the noise power, whereas at small biases there appears additional noise, which is probably due to the flux flow. We propose the prescription of how to minimize the influence of the current distribution on the mixer performance.
|
|