Jiang, L., Antipov, S. V., Voronov, B. M., Gol'tsman, G. N., Zhang, W., Li, N., et al. (2007). Characterization of the performance of a quasi-optical NbN superconducting HEB mixer. IEEE Trans. Appl. Supercond., 17(2), 395–398.
Abstract: In this paper we focus mainly on the investigation of the performance of a quasi-optical (planar log-spiral antenna) phonon-cooled NbN superconducting hot electron bolometer (HEB) mixer, which is cryogenically cooled by a close-cycled 4-K cryocooler, at 500 and 850 GHz frequency bands. The mixer's noise performance, stability of IF output power, and local oscillator (LO) power requirement are characterized for three NbN superconducting HEB devices of different sizes. The transmission characteristics of Mylar and Zitex films with incidence waves of an elliptical polarization are also examined by measuring the mixer's noise temperature. The lowest receiver noise temperatures (with no corrections) of 750 and 1100 K are measured at 500 and 850 GHz, respectively. Experimental results also demonstrate that the bigger the HEB device is, the higher the stability of IF output power becomes.
|
|
|
Il'in, K. S., Cherednichenko, S. I., Gol'tsman, G. N., Currie, M., & Sobolewski, R. (1998). Comparative study of the bandwidth of phonon-cooled NbN hot-electron bolometers in submillimeter and optical wavelength ranges. In Proc. 9th Int. Symp. Space Terahertz Technol. (pp. 323–330).
Abstract: We report the results of the bandwidth measurements of NbN hot-electron bolometers, perfomied in the terahertz frequency domain at 140 GHz and 660 GHz and in time domain in the optical range at the wavelength of 395 nm.. Our studies were done on 3.5-nm-thick NbN films evaporated on sapphire substrates and patterned into ilin-size microbridges. In order to measure the gain bandwidth, we used two identical BWOs (140 or 660 GHz), one functioning as a local oscillator and the other as a signal source. The bandwidth we achieved was 3.5-4 GHz at 4.2 K with the optimal LO and DC biases. Time-domain measurements with a resolution below 300 fs were performed using an electro-optic sampling system, in the temperature range between 4.2 K to 9 K at various values of the bias current and optical power. The obtained response time of the NbN hot-electron bolometer to —100- fs-wide Ti:sapphire laser pulses was about 27 ps, what corresponds to the 5.9 GHz gain bandwidth.
|
|
|
Svechnikov, S. I., Antipov, S. V., Vakhtomin, Y. B., Goltsman, G. N., Gershenzon, E. M., Cherednichenko, S. I., et al. (2001). Conversion and noise bandwidths of terahertz NbN hot-electron bolometer mixers. Physics of Vibrations, 9(3), 205–210.
|
|
|
Zhang, W., Li, N., Jiang, L., Ren, Y., Yao, Q. - J., Lin, Z. - H., et al. (2008). Dependence of noise temperature of quasi-optical superconducting hot-electron bolometer mixers on bath temperature and optical-axis displacement. In C. Zhang, & X. - C. Zhang (Eds.), Proc. SPIE (Vol. 6840, 684007 (1 to 8)). Spie.
Abstract: It is known that the increase of bath temperature results in the decrease of critical current of superconducting hot-electron bolometer (HEB) mixers owing to the depression of superconductivity, thus leading to the degradation of the mixer’s sensitivity. Here we report our study on the effect of bath temperature on the heterodyne mixing performance of quasi-optical superconducting NbN HEB mixers incorporated with a two-arm log-spiral antenna. The correlation between the bath temperature, critical current, LO power requirement and noise temperature is investigated at 0.5 THz. Furthermore, the heterodyne mixing performance of quasi-optical superconducting NbN HEB mixers is examined while there is an optical-axis displacement between the center of the extended hemispherical silicon lens and the superconducting NbN HEB device, which is placed on the back of the lens. Detailed experimental results and analysis are presented.
|
|
|
Shcherbatenko, M., Lobanov, Y., Finkel, M., Maslennikov, S., Pentin, I., Semenov, A., et al. (2014). Development of a 30 THz heterodyne receiver based on a hot-electron-bolometer mixer. In Proc. 25th Int. Symp. Space Terahertz Technol. (122).
Abstract: We present new Hot-Electron-Bolometer (HEB) mixers designed for mid-IR spectroscopy targeting astrophysical and geophysical observations where high sensitivity and spectral resolution are required. The mixers are made of an ultrathin NbN film deposited on GaAs substrates. Two entirely different types of the devices have been fabricated. The first type is based on a direct radiation coupling concept and the mixing devices are shaped as squares of 5×5 μm 2 (which corresponds to the diffraction limit at the chosen wavelength) and 10×10 μm 2 (which was used to establish a possible influence of the contact pads on the radiation absorption). The second type utilizes a spiral antenna designed with HFSS. The fabrication and layout of the devices as well as the performance comparison will be presented. During the experiments, the HEB mixer was installed on the cold plate of a LHe cryostat. A germanium window and an extended semi-spherical germanium lens are used to couple the radiation. The cryostat is equipped with a germanium optical filter of thickness 0.5 mm and with a center wavelength of 10.6 mμ. The incident power absorption is measured by using the isothermal method. As a Local Oscillator, a 10.6 micrometers line of a CO2 gas laser is used. We further characterize the frequency response of the spiral antenna with a FIR-spectrometer. The noise characteristics of the mixers are determined from a room temperature cold load and a heated black body at ~600 K as a hot load.
|
|