|
(2001). ГОСТ 2.102-68. ЕСКД. Виды и комплектность конструкторских документов.
|
|
|
(2001). ГОСТ 19.301-2000. ЕСКД. Программа и методика испытаний. Требования к содержанию, оформлению и контролю качества.
|
|
|
(2001). ГОСТ Р 15.201-2000. Продукция производственно-технического назначения. Порядок разработки и постановки продукции на производство.
|
|
|
Antipov, S. V., Svechnikov, S. I., Smirnov, K. V., Vakhtomin, Y. B., Finkel, M. I., Goltsman, G. N., et al. (2001). Noise temperature of quasioptical NbN hot electron bolometer mixers at 900 GHz. Physics of Vibrations, 9(4), 242–245.
|
|
|
Betz, A. L., Boreiko, R. T., Sivananthan, S., & Ashokan, R. (2001). HgCdTe photoconductive mixers for 2-8 THz. In C. Iit.u.t.e of T. Jet Propulsion Laboratory (Ed.), Proc. 12th Int. Symp. Space Terahertz Technol. (pp. 92–101). San Diego, CA, USA.
|
|
|
Boreman, G. D. (2001). A Users guide to IR detectors. In Proc. SPIE (Vol. 4420, pp. 79–90).
Abstract: This paper will guide the first-time user toward proper selection and use of IR detectors for applications in industrial inspection, process control, and laser measurements.
|
|
|
Chen, P. S. (2001). Infrared properties of barium stars. A&A, 372(1), 245–248.
|
|
|
Cherednichenko, S., Kroug, M., Merkel, H., Kollberg, E., Loudkov, D., Smirnov, K., et al. (2001). Local oscillator power requirement and saturation effects in NbN HEB mixers. In C. Iit.u.t.e of T. Jet Propulsion Laboratory (Ed.), Proc. 12th Int. Symp. Space Terahertz Technol. (pp. 273–285). San Diego, CA, USA.
Abstract: The local oscillator power required for NbN hot-electron bolometric mixers (P LO ) was investigated with respect to mixer size, critical temperature and ambient temperature. P LO can be decreased by a factor of 10 as the mixer size decreases from 4×0.4 µm 2 to 0.6×0.13 µm 2 . For the smallest volume mixer the optimal local oscillator power was found to be 15 nW. We found that for such mixer no signal compression was observed up to an input signal of 2 nW which corresponds to an equivalent input load of 20,000 K. For a constant mixer volume, reduction of T c can decrease optimal local oscillator power at least by a factor of 2 without a deterioration of the receiver noise temperature. Bath temperature was found to have minor effect on the receiver characteristics.
|
|
|
Codreanu, I., & Boreman, G. D. (2001). Infrared microstrip dipole antennas. Microw Opt Technol Lett, 29(6), 381–383.
Abstract: Abstract 10.1002/mop.1184.abs We report on the successful use of niobium microbolometers coupled to microstrip dipole antennas for the detection of midinfrared radiation. Measurements of the detector response versus antenna length performed at the 10.6 μm wavelength allowed us to identify the first three current-wave resonances along the antenna arms. The detector response was also measured as a function of the radiation wavelength in the 911 μm spectral domain. Excellent agreement between the experimental results and finite-difference time-domain (FDTD) predictions was obtained.
|
|
|
Danny Wilms Floet. (2001). Hotspot mixing in THz niobium superconducting hot electron bolometer mixers. Ph.D. thesis, , Netherlands.
|
|