Lobanov, Y., Tong, C., Blundell, R., & Gol'tsman, G. (2009). A study of direct detection effect on the linearity of hot electron bolometer mixers. In Proc. 20th Int. Symp. Space Terahertz Technol. (pp. 282–287).
Abstract: We have performed a study of how direct detection affects the linearity and hence the calibration of an HEB mixer. Two types of waveguide HEB devices have been used: a 0.8 THz HEB mixer and a 1.0 THz HEB mixer which is ~5 times smaller than the former. Two independent experimental approaches were used. In the ΔG/G method, the conversion gain of the HEB mixer is first measured as a function of the bias current for a number of bias voltages. At each bias setting, we carefully measure the change in the operating current when the input loads are switched. From the measured data, we can derive the expected difference in gain between the hot and cold loads. In the second method (injection method [1]), the linearity of the HEB mixer is independently measured by injecting a modulated signal for different input load temperatures. The results of both approaches confirm that there is gain compression in the operation of HEB mixers. Based on the results of our measurements, we discuss the impact of direct detection effects on the operation of HEB mixers.
|
Lieberzeit, P. A., & Dickert, F. L. (2009). Chemosensors in environmental monitoring: challenges in ruggedness and selectivity. Anal Bioanal Chem, 393(2), 467–472.
Abstract: Environmental analysis is a potential key application for chemical sensors owing to their inherent ability to detect analytes on-line and in real time in distributed systems. Operating a chemosensor in a natural environment poses substantial challenges in terms of ruggedness, long-term stability and calibration. This article highlights current trends of achieving both the necessary selectivity and ruggedness: one way is deploying sensor arrays consisting of robust broadband sensors and extracting information via chemometrics. If using only a single sensor is desired, molecularly imprinted polymers offer a straightforward way for designing artificial recognition materials. Molecularly imprinted polymers can be utilized in real-life environments, such as water and air, aiming at detecting analytes ranging from small molecules to entire cells.
|
Li, C. - T., Chen, T. - J., Ni, T. - L., Lu, W. - C., Chiu, C. - P., Chen, C. - W., et al. (2009). Development of SIS mixers for SMA 400-520 GHz band. In Proc. 20th Int. Symp. Space Terahertz Technol. (pp. 24–30).
Abstract: SIS junction mixers were developed for SMA 400-520 GHz band. The results show receiver noise temperature around 100 K across the band, with noise contribution from RF loss and IF estimated to be around 50 K and 20K, respectively. Two schemes were used to tune out junction's parasitic capacitance. When a parallel inductor is employed, the input impedance is close to Rn, which facilitates impedance matching between the junction and the waveguide probe. Waveguide probes were designed to achieve a low feed-point impedance to match to the junction resistance. Optimum embedding impedances for lower receiver noise temperature were investigated. Performances of two schemes and composition of receiver noise were also discussed.
|
Khosropanah P., Baryshev A., Zhang W., Jellema W., Hovenier J.N., Gao G.R., et al. (2009). Phase-locking of a 2.7-THz quantum cascade laser to a microwave reference. Optics Letters, 34, 2958–2960.
Abstract: We demonstrate the phase locking of a 2.7 THz metal–metal waveguide quantum cascade laser (QCL) to an external microwave signal. The reference is the 15th harmonic, generated by a semiconductor superlattice nonlinear device, of a signal at 182 GHz, which itself is generated by a multiplier chain (X12) from a
microwave synthesizer at ~ 15 GHz. Both laser and reference radiations are coupled into a bolometer mixer, resulting in a beat signal, which is fed into a phase-lock loop. The spectral analysis of the beat signal con-firms that the QCL is phase locked. This result opens the possibility to extend heterodyne interferometers into the far-infrared range.
|
Kern, P., Le Coärer, E., & Benech, P. (2009). On-chip spectro-detection for fully integrated coherent beam combiners. Opt.Express, 17(3), 1976–1987.
Abstract: This paper presents how photonics associated with new arising detection technologies is able to provide fully integrated instrument for coherent beam combination applied to astrophysical interferometry. The feasibility and operation of on-chip coherent beam combiners has been already demonstrated using various interferometric combination schemes. More recently we proposed a new detection principle aimed at directly sampling and extracting the spectral information of an input signal together with its flux level measurement. The so-called SWIFTS demonstrated concept that stands for Stationary-Wave Integrated Fourier Transform Spectrometer, provides full spectral and spatial information recorded simultaneously thanks to a motionless detecting device. Due to some newly available detection principles considered for the implementation of the SWIFTS concept, some technologies can even provide photo-counting operation that brought a significant extension of the interferometry domain of investigation in astrophysics. The proposed concept is applicable to most of the interferometric instrumental modes including fringe tracking, fast and sensitive detection, Fourier spectral reconstruction and also to manage a large number of incoming beams. The paper presents three practical implementations, two dealing with pair-wise integrated optics beam combinations and the third one with an all-in-one 8 beam combination. In all cases the principles turned into a pair wise baseline coding after proper data processing.
|