|
Goltsman, G. N. (2009). Ultrafast nanowire superconducting single-photon detector with photon number resolving capability. In Y. Arakawa, M. Sasaki, & H. Sotobayashi (Eds.), Proc. SPIE (Vol. 7236, 72360D (1 to 11)). SPIE.
Abstract: In this paper we present a review of the state-of-the-art superconducting single-photon detector (SSPD), its characterization and applications. We also present here the next step in the development of SSPD, i.e. photon-number resolving SSPD which simultaneously features GHz counting rate. We have demonstrated resolution up to 4 photons with quantum efficiency of 2.5% and 300 ps response pulse duration providing very short dead time.
|
|
|
Zhizhon, Y., & Majedi, H. A. (2009). Optoelectronic mixing in the NbN superconducting nanowire single photon detectors. In Proc. SPIE (Vol. 3786, 9).
Abstract: In this paper, we present our experimental results on the electrically pumped optoelectronic mixing effect exhibited in a niobium nitride (NbN) superconducting nanowire. The experimental setup in order to test the mixer has been reported in detail. This superconductive nanowire optoelectronic mixer demonstrates photodetection and mixing in an integrated manner. We have explored both effects under a great variety of external conditions, such as temperature and bias current, in order to seek potential ways toward quantum optoelectronic detection and mixing by such nanowire device.
|
|
|
Ovchinnikov, Y. N., & Varlamov, A. A. (2009). Fluctuation-dissipative phenomena in a narrow superconducting channel carrying current below critical. arXiv, 0910.2659v1, 1–4.
Abstract: The theory of current transport in a narrow superconducting channel accounting for thermal fluctuations is developed. These fluctuations result in the appearance of small but finite dissipation in the sample. The value of corresponding voltage is found as the function of temperature (close to transition temperature) and arbitrary bias current. It is demonstrated that the value of the activation energy (exponential factor in the Arrenius law) when current approaches to the critical one is proportional to (1-J/Jc)^(5/4). This result is in concordance with the one for the affine phenomenon of the Josephson current decay due to the thermal phase fluctuations, where the activation energy proportional (1-J/J_c)^(3/2)(the difference in the exponents is related to the additional current dependence of the order parameter). Found dependence of the activation energy on current explains the enormous discrepancy between the theoretically predicted before and the experimentally observed broadening of the resistive transition.
|
|
|
Lieberzeit, P. A., & Dickert, F. L. (2009). Chemosensors in environmental monitoring: challenges in ruggedness and selectivity. Anal Bioanal Chem, 393(2), 467–472.
Abstract: Environmental analysis is a potential key application for chemical sensors owing to their inherent ability to detect analytes on-line and in real time in distributed systems. Operating a chemosensor in a natural environment poses substantial challenges in terms of ruggedness, long-term stability and calibration. This article highlights current trends of achieving both the necessary selectivity and ruggedness: one way is deploying sensor arrays consisting of robust broadband sensors and extracting information via chemometrics. If using only a single sensor is desired, molecularly imprinted polymers offer a straightforward way for designing artificial recognition materials. Molecularly imprinted polymers can be utilized in real-life environments, such as water and air, aiming at detecting analytes ranging from small molecules to entire cells.
|
|
|
Benford, D., Moseley, H., & Zmuidzinas, J. (2009). Direct detectors for the Einstein inflation probe. In J. Phys.: Conf. Ser. (Vol. 155, 012001 (1 to 49)).
Abstract: Here we review the principles of operation, history, present status, and future prospects for the primary candidate detectors for Cosmic Microwave Background (CMB) polarization studies. The three detector types we will discuss are semiconductor-based bolometers, superconducting transition edge sensor (TES) bolometer, and Microwave Kinetic Inductance Detectors (MKIDs). All of these detector types can provide the sensitivity to permit background-limited measurements of the CMB, but the ultimate selection of detectors will be largely determined by the ease of production and reliability of large arrays of such detectors. This paper describes the present state of development of these detectors, efforts to integrate them into large arrays, and the detector system developments necessary to enable a space CMB polarization mission.
|
|