Smirnov, K., Vachtomin, Y., Divochiy, A., Antipov, A., & Goltsman, G. (2015). Dependence of dark count rates in superconducting single photon detectors on the filtering effect of standard single mode optical fibers. Appl. Phys. Express, 8(2), 022501 (1 to 4).
|
|
|
Takesue, H., Dyer, S. D., Stevens, M. J., Verma, V., Mirin, R. P., & Nam, S. W. (2015). Quantum teleportation over 100 km of fiber using highly efficient superconducting nanowire single-photon detectors. Optica, 2.
Abstract: Quantum teleportation is an essential quantum operation by which we can transfer an unknown quantum state to a remote location with the help of quantum entanglement and classical communication. Since the first experimental demonstrations using photonic qubits and continuous variables, the distance of photonic quantum teleportation over free-space channels has continued to increase and has reached >100 km. On the other hand, quantum teleportation over optical fiber has been challenging, mainly because the multifold photon detection that inevitably accompanies quantum teleportation experi- ments has been very inefficient due to the relatively low de- tection efficiencies of typical telecom-band single-photon detectors. Here, we report on quantum teleportation over optical fiber using four high-detection-efficiency supercon- ducting nanowire single-photon detectors (SNSPDs). These SNSPDs make it possible to perform highly efficient multi- fold photon measurements, allowing us to confirm that the quantum states of input photons were successfully tele- ported over 100 km of fiber with an average fidelity of 83.7 2.0%.
|
|
|
Anosov, A. A., Nemchenko, O. Y., Less, Y. A., Kazanskii, A. S., & Mansfel'd, A. D. (2015). Possibilities of acoustic thermometry for controlling targeted drug delivery. Acoust. Phys., 61(4), 488–493.
Abstract: Model acoustic thermometry experiments were conducted during heating of an aqueous liposome suspension. Heating was done to achieve the liposome phase transition temperature. At the moment of the phase transition, the thermal acoustic signal achieved a maximum and decreased, despite continued heating. During subsequent cooling of the suspension, when lipids again passed through the phase transition point, the thermal acoustic signal again increased, despite a reduction in temperature. This effect is related to an increase in ultrasound absorption by the liposome suspension at the moment of the lipid phase transition. The result shows that acoustic thermography can be used to control targeted delivery of drugs mixed in thermally sensitive liposomes, the integrity of which is violated during heating to the phase transition temperature.
|
|
|
Sidorova, M. V., Divochiy, A. V., Vakhtomin, Y. B., & Smirnov, K. V. (2015). Ultrafast superconducting single-photon detector with a reduced active area coupled to a tapered lensed single-mode fiber. J. Nanophoton., 9(1), 093051.
Abstract: This paper presents an ultrafast niobium nitride (NbN) superconducting single-photon detector (SSPD) with an active area of 3×3 μm2 that offers better timing performance metrics than the previous SSPD with an active area of 7×7 μm2. The improved SSPD demonstrates a record timing jitter (<25 ps), an ultrashort recovery time (<2 ns), an extremely low dark count rate, and a high detection efficiency in a wide spectral range from visible part to near infrared. The record parameters were obtained due to the development of a new technique providing effective optical coupling between a detector with a reduced active area and a standard single-mode telecommunication fiber. The advantages of the new approach are experimentally confirmed by taking electro-optical measurements.
|
|
|
Korneev, A. A., Korneeva, Y. P., Mikhailov, M. Y., Pershin, Y. P., Semenov, A. V., Vodolazov, D. Y., et al. (2015). Characterization of MoSi superconducting single-photon detectors in the magnetic field. IEEE Trans. Appl. Supercond., 25(3), 2200504 (1 to 4).
Abstract: We investigate the response mechanism of nanowire superconducting single-photon detectors (SSPDs) made of amorphous MoxSi1-x. We study the dependence of photon count and dark count rates on bias current in magnetic fields up to 113 mT at 1.7 K temperature. The observed behavior of photon counts is similar to the one recently observed in NbN SSPDs. Our results show that the detecting mechanism of relatively high-energy photons does not involve the vortex penetration from the edges of the film, and on the contrary, the detecting mechanism of low-energy photons probably involves the vortex penetration from the film edges.
|
|