|
Gayduchenko, I., Fedorov, G., Titova, N., Moskotin, M., Obraztsova, E., Rybin, M., et al. (2018). Towards to the development of THz detectors based on carbon nanostructures. In J. Phys.: Conf. Ser. (Vol. 1092, 012039 (1 to 4)).
Abstract: Demand for efficient terahertz radiation detectors resulted in intensive study of the carbon nanostructures as possible solution for that problem. In this work we investigate the response to sub-terahertz radiation of detectors with sensor elements based on CVD graphene as well as its derivatives – carbon nanotubes (CNTs). The devices are made in configuration of field effect transistors (FET) with asymmetric source and drain (vanadium and gold) contacts and operate as lateral Schottky diodes. We show that at 300K semiconducting CNTs show better performance up to 300GHz with responsivity up to 100V/W, while quasi-metallic CNTs are shown to operate up to 2.5THz. At 300 K graphene detector exhibit the room-temperature responsivity from R = 15 V/W at f = 129 GHz to R = 3 V/W at f = 450 GHz. We find that at low temperatures (77K) the graphene lateral Schottky diodes responsivity rises with the increasing frequency of the incident sub-THz radiation. We interpret this result as a manifestation of a plasmonic effect in the devices with the relatively long plasmonic wavelengths. The obtained data allows for determination of the most promising directions of development of the technology of nanocarbon structures for the detection of THz radiation.
|
|
|
Golikov, A., Kovalyuk, V., An, P., Zubkova, E., Ferrari, S., Pernice, W., et al. (2018). Silicon nitride nanophotonic circuit for on-chip spontaneous four-wave mixing. In J. Phys.: Conf. Ser. (Vol. 1124, 051051).
Abstract: Here we present an integrated nanophotonic circuit for on-chip spontaneous four-wave mixing. The fabricated device includes an O-ring resonator, a Bragg noch-filter as well as a nine-channel arrayed waveguide gratings (AWG) operated in the C-band wavelength range (1550 nm). The measured optical losses of the device (-6.8 dB) as well as a high Q-factor (> 1.2×105) shows a good potential for realizing the spontaneous four-wave mixing on the silicon nitride chip.
|
|
|
Goltsman, G., Naumov, A. V., Gladush, M. G., & Karimullin, K. R. (2018). Quantum photonic integrated circuits with waveguide integrated superconducting nanowire single-photon detectors. In EPJ Web Conf. (Vol. 190, 02004 (1 to 2)).
Abstract: We show the design, a history of development as well as the most successful and promising approaches for QPICs realization based on hybrid nanophotonic-superconducting devices, where one of the key elements of such a circuit is a waveguide integrated superconducting single-photon detector (WSSPD). The potential of integration with fluorescent molecules is discussed also.
|
|
|
Iomdina, E. N., Seliverstov, S. V., Sianosyan, A. A., Teplyakova, K. O., Rusova, A. A., & Goltsman, G. N. (2018). Terahertz scanning for evaluation of corneal and scleral hydration. STM, 10(4), 143–149.
Abstract: The aim of the investigation was to study the prospects of using continuous THz scanning of the cornea and the sclera to determine water concentration in these tissues and on the basis of the obtained data to develop the experimental installation for monitoring corneal and scleral hydration degree.Materials and Methods. To evaluate corneal and scleral transmittance and reflectance spectra in the THz range, the developed experimental installations were used to study 3 rabbit corneas and 3 scleras, 2 whole rabbit eyes, and 3 human scleras. Besides, two rabbit eyes were studied in vivo prior to keratorefractive surgery as well as 10 and 21 days following the surgery (LASIK).Results. There have been created novel experimental installations enabling in vitro evaluation of frequency dependence of corneal and scleral transmittance coefficients and reflectance coefficients on water percentage in the THz range. Decrease in corneal water content by 1% was found to lead to reliably established decrease in the reflected signal by 13%. The reflectance spectrum of the whole rabbit eye was measured in the range of 0.13–0.32 THz. The study revealed the differences between the indices of rabbit cornea and sclera, as well as rabbit and human sclera. There was developed a laboratory model of the installation for in vivo evaluation of corneal and scleral hydration using THz radiation.Conclusion. The preliminary findings show that the proposed technique based on the use of continuous THz radiation can be employed to create a device for noninvasive control of corneal and scleral hydration.
|
|
|
Komrakova, S., Javadzade, J., Vorobyov, V., Bolshedvorskii, S., Soshenko, V., Akimov, A., et al. (2018). On-chip controlled placement of nanodiamonds with a nitrogen-vacancy color centers (NV). In J. Phys.: Conf. Ser. (Vol. 1124, 051046 (1 to 4)).
Abstract: Here we studied the fabrication technique of a kilopixel array of nanodiamonds with a nitrogen-vacancy color centers (NV) on top of the chip and measured the second-order correlation function deep, clearly demonstrated the presence of single-photon sources. The controlled position of nanodiamonds, determined from the measurement of second-order correlation fiction, was realize, as well as the yield of optimized technique equals 12.5% is shown.
|
|