TY - JOUR AU - Poglitsch, A. AU - Waelkens, C. AU - Geis, N. AU - Feuchtgruber, H. AU - Vandenbussche, B. AU - Rodriguez, L. AU - Krause, O. AU - Renotte, E. AU - van Hoof, C. AU - Saraceno, P. AU - Cepa, J. AU - Kerschbaum, F. AU - Agnèse, P. AU - Ali, B. AU - Altieri, B. AU - Andreani, P. AU - Augueres, J-L AU - Balog, Z. AU - Barl, L. AU - Bauer, O. H. AU - Belbachir, N. AU - Benedettini, M. AU - Billot, N. AU - Boulade, O. AU - Bischof, H. AU - Blommaert, J. AU - Callut, E. AU - Cara, C. AU - Cerulli, R. AU - Cesarsky, D. AU - Contursi, A. AU - Creten, Y. AU - De Meester, W. AU - Doublier, V. AU - Doumayrou, E. AU - Duband, L. AU - Exter, K. AU - Genzel, R. AU - Gillis, J-M AU - Grözinger, U. AU - Henning, T. AU - Herreros, J. AU - Huygen, R. AU - Inguscio, M. AU - Jakob, G. AU - Jamar, C. AU - Jean, C. AU - de Jong, J. AU - Katterloher, R. AU - Kiss, C. AU - Klaas, U. AU - Lemke, D. AU - Lutz, D. AU - Madden, S. AU - Marquet, B. AU - Martignac, J. AU - Mazy, A. AU - Merken, P. AU - Montfort, F. AU - Morbidelli, L. AU - Müller, T. AU - Nielbock, M. AU - Okumura, K. AU - Orfei, R. AU - Ottensamer, R. AU - Pezzuto, S. AU - Popesso, P. AU - Putzeys, J. AU - Regibo, S. AU - Reveret, V. AU - Royer, P. AU - Sauvage, M. AU - Schreiber, J. AU - Stegmaier, J. AU - Schmitt, D. AU - Schubert, J. AU - Sturm, E. AU - Thiel, M. AU - Tofani, G. AU - Vavrek, R. AU - Wetzstein, M. AU - Wieprecht, E. AU - Wiezorrek, E. PY - 2010 DA - 2010// TI - The Photodetector Array Camera and Spectrometer (PACS) on the Herschel Space Observatory T2 - A&A JO - Astron. Astrophys. SP - 12 VL - 518 KW - PACS AB - The Photodetector Array Camera and Spectrometer (PACS) is one of the three science instruments on ESA's far infrared and submillimetre observatory. It employs two Ge:Ga photoconductor arrays (stressed and unstressed) with 16×25 pixels, each, and two filled silicon bolometer arrays with 16×32 and 32×64 pixels, respectively, to perform integral-field spectroscopy and imaging photometry in the 60-210 μm wavelength regime. In photometry mode, it simultaneously images two bands, 60-85 μm or 85-125 μm and 125-210 μm, over a field of view of ~1.75'× 3.5', with close to Nyquist beam sampling in each band. In spectroscopy mode, it images a field of 47” × 47”, resolved into 5×5 pixels, with an instantaneous spectral coverage of ~1500 km s-1 and a spectral resolution of ~175 km s-1. We summarise the design of the instrument, describe observing modes, calibration, and data analysis methods, and present our current assessment of the in-orbit performance of the instrument based on the performance verification tests. PACS is fully operational, and the achieved performance is close to or better than the pre-launch predictions. N1 - exported from refbase (https://db.rplab.ru/refbase/show.php?record=694), last updated on Sat, 04 Jun 2016 09:42:13 -0500 ID - Poglitsch_etal2010 ER -