2013 |
|
Lusche R, Semenov A, Huebers H-W, Ilin K, Siegel M, Korneeva Y, et al. Effect of the wire geometry and an externally applied magnetic field on the detection efficiency of superconducting nanowire single-photon detectors [abstract]. In: INIS. Vol 46.; 2013. p. 1–3.
Abstract: The interest in single-photon detectors in the near-infrared wavelength regime for applications, e.g. in quantum cryptography has immensely increased in the last years. Superconducting nanowire single-photon detectors (SNSPD) already show quite reasonable detection efficiencies in the NIR which can even be further improved. Novel theoretical approaches including vortex-assisted photon counting state that the detection efficiency in the long wavelength region can be enhanced by the detector geometry and an applied magnetic field. We present spectral measurements in the wavelength range from 350-2500 nm of the detection efficiency of meander-type TaN and NbN SNSPD with varying nanowire line width from 80 to 250 nm. Due to the used experimental setup we can accurately normalize the measured spectra and are able to extract the intrinsic detection efficiency (IDE) of our detectors. The results clearly indicate an improvement of the IDE depending on the wire width according to the theoretic models. Furthermore we experimentally found that the smallest detectable photon-flux can be increased by applying a small magnetic field to the detectors.
|
|
|
Marsili F, Verma VB, Stern JA, Harrington S, Lita AE, Gerrits T, et al. Detecting single infrared photons with 93% system efficiency. Nat. Photon.. 2013;7(3):210–4.
Abstract: Single-photon detectors1 at near-infrared wavelengths with high system detection efficiency (>90%), low dark count rate (<1 c.p.s.), low timing jitter (<100 ps) and short reset time (<100 ns) would enable landmark experiments in a variety of fields2, 3, 4, 5, 6. Although some of the existing approaches to single-photon detection fulfil one or two of the above specifications1, to date, no detector has met all of the specifications simultaneously. Here, we report on a fibre-coupled single-photon detection system that uses superconducting nanowire single-photon detectors7 and closely approaches the ideal performance of single-photon detectors. Our detector system has a system detection efficiency (including optical coupling losses) greater than 90% in the wavelength range λ = 1,520–1,610 nm, with a device dark count rate (measured with the device shielded from any background radiation) of ~1 c.p.s., timing jitter of ~150 ps full-width at half-maximum (FWHM) and reset time of 40 ns.
|
|
|
McCarthy A, Krichel NJ, Gemmell NR, Ren X, Tanner MG, Dorenbos SN, et al. Kilometer-range, high resolution depth imaging via 1560 nm wavelength single-photon detection. Opt Express. 2013;21(7):8904–15.
Abstract: This paper highlights a significant advance in time-of-flight depth imaging: by using a scanning transceiver which incorporated a free-running, low noise superconducting nanowire single-photon detector, we were able to obtain centimeter resolution depth images of low-signature objects in daylight at stand-off distances of the order of one kilometer at the relatively eye-safe wavelength of 1560 nm. The detector used had an efficiency of 18% at 1 kHz dark count rate, and the overall system jitter was ~100 ps. The depth images were acquired by illuminating the scene with an optical output power level of less than 250 µW average, and using per-pixel dwell times in the millisecond regime.
|
|
|
Schuck C, Pernice WHP, Minaeva O, Li M, Gol'tsman G, Sergienko AV, et al. Matrix of integrated superconducting single-photon detectors with high timing resolution. IEEE Trans Appl Supercond. 2013;23(3):2201007.
Abstract: We demonstrate a large grid of individually addressable superconducting single photon detectors on a single chip. Each detector element is fully integrated into an independent waveguide circuit with custom functionality at telecom wavelengths. High device density is achieved by fabricating the nanowire detectors in traveling wave geometry directly on top of silicon-on-insulator waveguides. Our superconducting single photon detector matrix includes detector designs optimized for high detection efficiency, low dark count rate, and high timing accuracy. As an example, we exploit the high timing resolution of a particularly short nanowire design to resolve individual photon round-trips in a cavity ring-down measurement of a silicon ring resonator.
|
|
|
Zolotov P, Vakhtomin Y, Divochiy A, Seleznev V, Morozov P, Smirnov K. High-efficiency single-photon detectors based on NbN films.; 2013.
Abstract: We present our resent results in development and testing of Superconducting Single-Photon Detectors (SSPD) with detection efficiencies greater than 85%. High values of obtained results are assigned to proposed design of the detector with integrated resonator structure, including two-layer optical cavity and anti-reflective coating (ARC).
|
|
2012 |
|
Bulaevskii LN, Graf MJ, Kogan VG. Vortex-assisted photon counts and their magnetic field dependence in single-photon superconducting detectors. Phys Rev B. 2012;85(1):9.
Abstract: We argue that photon counts in a superconducting nanowire single-photon detector (SNSPD) are caused by the transition from a current-biased metastable superconducting state to the normal state. Such a transition is triggered by vortices crossing the thin and narrow superconducting strip from one edge to another due to the Lorentz force. Detector counts in SNSPDs may be caused by three processes: (a) a single incident photon with sufficient energy to break enough Cooper pairs to create a normal-state belt across the entire width of the strip (direct photon count), (b) thermally induced single-vortex crossing in the absence of photons (dark count), which at high-bias currents releases the energy sufficient to trigger the transition to the normal state in a belt across the whole width of the strip, and (c) a single incident photon of insufficient energy to create a normal-state belt but initiating a subsequent single-vortex crossing, which provides the rest of the energy needed to create the normal-state belt (vortex-assisted single-photon count). We derive the current dependence of the rate of vortex-assisted photon counts. The resulting photon count rate has a plateau at high currents close to the critical current and drops as a power law with high exponent at lower currents. While the magnetic field perpendicular to the film plane does not affect the formation of hot spots by photons, it causes the rate of vortex crossings (with or without photons) to increase. We show that by applying a magnetic field one may characterize the energy barrier for vortex crossings and identify the origin of dark counts and vortex-assisted photon counts.
|
|
|
Henrich D, Dorner S, Hofherr M, Il'in K, Semenov A, Heintze E, et al. Broadening of hot-spot response spectrum of superconducting NbN nanowire single-photon detector with reduced nitrogen content. J Appl Phys. 2012;112.
Abstract: The spectral detection efficiency and the dark count rate of superconducting nanowire
single-photon detectors (SNSPD) have been studied systematically on detectors made from thin
NbN films with different chemical compositions. Reduction of the nitrogen content in the 4 nm
thick NbN films results in a decrease of the dark count rates more than two orders of magnitude
and in a red shift of the cut-off wavelength of the hot-spot SNSPD response. The observed
phenomena are explained by an improvement of uniformity of NbN films that has been confirmed
by a decrease of resistivity and an increase of the ratio of the measured critical current to the
depairing current. The latter factor is considered as the most crucial for both the cut-off
wavelength and the dark count rates of SNSPD. Based on our results we propose a set of criteria
for material properties to optimize SNSPD in the infrared spectral region. VC 2012 American
Institute of Physics. [http://dx.doi.org/10.1063/1.4757625]
|
|
|
Inderbitzin K, Engel A, Schilling A, Il'in K, Siegel M. An ultra-fast superconducting Nb nanowire single-photon detector for soft x-rays. Appl Phys Lett. 2012;101.
Abstract: Although superconducting nanowire single-photon detectors (SNSPDs) are well studied regarding the
detection of infrared/optical photons and keV-molecules, no studies on continuous x-ray photon
counting by thick-film detectors have been reported so far. We fabricated a 100 nm thick niobium
x-ray SNSPD (an X-SNSPD) and studied its detection capability of photons with keV-energies in
continuous mode. The detector is capable to detect photons even at reduced bias currents of 0.4%,
which is in sharp contrast to optical thin-film SNSPDs. No dark counts were recorded in extended
measurement periods. Strikingly, the signal amplitude distribution depends significantly on the photon
energy spectrum.VC
|
|
|
Julia Toussaint RG Marco Schubert Torsten May Hans-Georg Meyer Benjamin Dietzek Jürgen Popp Matthias Hofherr Matthias Arndt Dagmar Henrich Konstantin Il'in and Michael Siegel. Superconducting single-photon counting system for optical experiments requiring time-resolution in the picosecond range. AIP REVIEW OF SCIENTIFIC INSTRUMENTS. 2012;83.
Abstract: We have developed a cryogenic measurement system for single-photon counting, which can be used
in optical experiments requiring high time resolution in the picosecond range. The system utilizes
niobium nitride superconducting nanowire single-photon detectors which are integrated in a timecorrelated
single-photon counting (TCSPC) setup. In this work, we describe details of the mechanical
design, the electrical setup, and the cryogenic optical components. The performance of the complete
system in TCSPC mode is tentatively benchmarked using 140 fs long laser pulses at a repetition
frequency of 75MHz. Due to the high temporal stability of these pulses, the measured time resolution
of 35 ps (FWHM) is limited by the timing jitter of the measurement system. The result was crosschecked
in a Coherent Anti-stokes Raman Scattering (CARS) setup, where scattered pulses from a
β-barium borate crystal have been detected with the same time resolution.
|
|
|
Korneev A, Korneeva Y, Florya I, Voronov B, Goltsman G. NbN nanowire superconducting single-photon detector for mid-infrared. Phys Procedia. 2012;36:72–6.
Abstract: Superconducting single-photon detectors (SSPD) is typically 100 nm-wide supercondiucting strip in a shape of meander made of 4-nm-thick film. To reduce response time and increase voltage response a parallel connection of the strips was proposed. Recently we demonstrated that reduction of the strip width improves the quantum effciency of such a detector at wavelengths longer than 1.5 μm. Being encourage by this progress in quantum effciency we improved the fabrication process and made parallel-wire SSPD with 40-nm-wide strips covering total area of 10 μm x 10 μm. In this paper we present the results of the characterization of such a parallel-wire SSPD at 10.6 μm wavelength and demonstrate linear dependence of the count rate on the light power as it should be in case of single-photon response.
|
|