Tiulina, V., Iomdina, E., Goltsman, G., Seliverstov, S., Sianosyan, A., Teplyakova, K., et al. (2019). UVB promotes the initiation of uveitic inflammatory and changes in thehydration of the cornea in vivo (Vol. 9).
Abstract: Recently, active research has been conducted in the field of terahertz (THz) scanning of human tissues for noninvasive determination of their hydration level, which haves hown high diagnostic efficiency of this technology in various pathological conditions. Recently, we have developed a laboratory model of the facility for monitoring the state of the water balance of the cornea using THz scanning in vivo, which opens up the possibility of applying this approach in ophthalmology. The aim of the work wasto compare the results of the THz scan of the cornea with its clinical changes using the example of an experimental model of the UV induced keratouveitis. Anexperimental study, which included a comprehensive assessment of clinical changes in the cornea of rabbits during keratouveitis induction, revealed a decrease in the stability of the tear film, pathological changes in the corneal epithelium and stroma, as well as its anatomical and optical parameters. Comparison of data obtained in the THz scan of the cornea with tears production, optical coherence tomography and confocal microscopy showed their consistency in all observation periods, which allows us to conclude that the developed laboratory setup works and the feasibility of further research to promote the corneal hydration evaluation technology in clinical practice. Acknowledgements: Research was funded by the RSF, grant number 161500255.
|
Prokhodtsov, A., Golikov, A., An, P., Kovalyuk, V., Goltsman, G., Arakelyan, S., et al. (2019). Effect of silicon oxide coating on a silicon nitride focusing grating coupler efficiency. In EPJ Web Conf. (Vol. 220, 02009).
Abstract: The dependence of the efficiency of the focusing grating couplers on the period and filling factor before and after deposition of the upper silicon oxide layer was experimentally studied. The obtained data are of practical importance for tunable integrated-optical devices based on silicon nitride platform.
|
Kovaluyk, V., Lazarenko, P., Kozyukhin, S., An, P., Prokhodtsov, A., Goltsman, G., et al. (2019). Influence of the phase state of Ge2Sb2Te5 thin cover on the parameters of the optical waveguide structures. In Proc. Amorphous and Nanostructured Chalcogenides (pp. 47–48). Technical University of Moldova.
Abstract: The fast switching time of Ge-Sb-Te thin films between amorphous and crystalline states initiated by laser beam as well as significant change of their optical properties and the preservation of metastable states for tens of years open wide perspectives for the application of these materials to fully optical devices [1], including high-speed optical memory [2]. Here we study optical properties of the Ge2Sb2Te5 (GST225) thin films integrated with on-chip silicon nitride O-ring resonator. The rib waveguide of the resonator was formed the first stage of e-beam lithography and subsequent reactive-ion etching. We used the second stage of e-beam lithography combining with lift-off method for the formation of GST225 active region on the resonator ring surface. The amorphous GST225 thin films were prepared by magnetron sputtering, and were capped by thin silicon oxide on their tops. The length of the GST225 active region varied from 0.1 to 20 μ m. Crystallization of amorphous thin films was carried out at the temperature of 400 °C for 30 minutes. Auger electron spectroscopy and transmission electron microscopy were used for studying composition and structure of investigated GST225thin films, respectively. It was observed that crystallization of amorphous GST225 film lead to a decrease of the optical power, transmitted through the waveguide. Comparison of the optical transmittance of O-ring resonators before and after the GST225 deposition allowed to identify the change in the Q-factor and the wavelength peak shift. This can be explained by the differences of the complex refractive indexes of GST225 thin films in the amorphous and crystalline states. From the measurement data, the GST225 effective refractive index was extracted depending on the ring waveguide width of the resonator for a telecommunication wavelength of 1550 nm.
|
Nikogosyan, A. S., Martirosyan, R. M., Hakhoumian, A. A., Makaryan, A. H., Tadevosyan, V. R., Goltsman, G. N., et al. (2019). Effect of absorption on the efficiency of terahertz radiation generation in the metal waveguide partially filled with nonlinear crystal LiNbO3, DAST or ZnTe. J. Contemp. Phys., 54(1), 97–104.
Abstract: The influence of terahertz (THz) radiation absorption on the efficiency of generation of coherent THz radiation in the system ‘nonlinear-optical crystal partially filling the cross section of a rectangular metal waveguide’ has been investigated. The efficiency of the nonlinear frequency conversion of optical laser radiation to the THz range depends on the loss in the system and the fulfillment of the phase-matching (FM) condition in a nonlinear crystal. The method of partially filling of a metal waveguide with a nonlinear optical crystal is used to ensure phase matching. The phase matching is achieved by numerical determination of the thickness of the nonlinear crystal, that is the degree of partial filling of the waveguide. The attenuation of THz radiation caused by losses both in the metal walls of the waveguide and in the crystal was studied, taking into account the dimension of the cross section of the waveguide, the degree of partial filling, and the dielectric constant of the crystal. It is shown that the partial filling of the waveguide with a nonlinear crystal results in an increase in the efficiency of generation of THz radiation by an order of magnitude, owing to the decrease in absorption.
|
Baksheeva, K., Vdovydchenko, A., Gorshkov, K., Ozhegov, R., Kinev, N., Koshelets, V., et al. (2019). Study of human skin radiation in the terahertz frequency range. In J. Phys.: Conf. Ser. (Vol. 1410, 012076 (1 to 5)).
Abstract: The radiation of human skin in the terahertz frequency range under the influence of mental stresses has been studied in the current work. An experimental setup for observation of changes in human skin radiation, which occur under the influence of psychological stresses, by means of a superconducting integrated receiver has been developed. More than 30 volunteers participate in these studies, which allows us to verify presence of correlation between the signals from the superconducting integrated terahertz receiver and other sensors that monitor human mental stress.
|
Moshkova, M., Divochiy, A., Morozov, P., Vakhtomin, Y., Antipov, A., Zolotov, P., et al. (2019). High-performance superconducting photon-number-resolving detectors with 86% system efficiency at telecom range. J. Opt. Soc. Am. B, 36(3), B20.
Abstract: The use of improved fabrication technology, highly disordered NbN thin films, and intertwined section topology makes it possible to create high-performance photon-number-resolving superconducting single-photon detectors (PNR SSPDs) that are comparable to conventional single-element SSPDs at the telecom range. The developed four-section PNR SSPD has simultaneously an 86±3% system detection efficiency, 35 cps dark count rate, ∼2 ns dead time, and maximum 90 ps jitter. An investigation of the PNR SSPD’s detection efficiency for multiphoton events shows good uniformity across sections. As a result, such a PNR SSPD is a good candidate for retrieving the photon statistics for light sources and quantum key distribution systems.
|
Saveskul, N. A., Titova, N. A., Baeva, E. M., Semenov, A. V., Lubenchenko, A. V., Saha, S., et al. (2019). Superconductivity behavior in epitaxial TiN films points at surface magnetic disorder. arXiv:1903.05009v3 [cond-mat.mtrl-sci].
Abstract: We analyze the evolution of the normal and superconducting electronic properties in epitaxial TiN films, characterized by high Ioffe-Regel parameter values, as a function of the film thickness. As the film thickness decreases, we observe an increase of in the residual resistivity, which becomes dominated by diffusive surface scattering for d≤20nm. At the same time, a substantial thickness-dependent reduction of the superconducting critical temperature is observed compared to the bulk TiN value. In such a high quality material films, this effect can be explained by a weak magnetic disorder residing in the surface layer with a characteristic magnetic defect density of ∼1012cm−2. Our results suggest that surface magnetic disorder is generally present in oxidized TiN films.
|
Saveskul, N. A., Titova, N. A., Baeva, E. M., Semenov, A. V., Lubenchenko, A. V., Saha, S., et al. (2019). Superconductivity behavior in epitaxial TiN films points to surface magnetic disorder. Phys. Rev. Applied, 12(5), 054001.
Abstract: We analyze the evolution of the normal and superconducting properties of epitaxial TiN films, characterized by high Ioffe-Regel parameter values, as a function of the film thickness. As the film thickness decreases, we observe an increase of the residual resistivity, that becomes dominated by diffusive surface scattering for d≤20nm. At the same time, a substantial thickness-dependent reduction of the superconducting critical temperature is observed compared to the bulk TiN value. In such high-quality material films, this effect can be explained by a weak magnetic disorder residing in the surface layer with a characteristic magnetic defect density of approximately 1012cm−2. Our results suggest that surface magnetic disorder is generally present in oxidized TiN films.
|
Elezov, M., Scherbatenko, M., Sych, D., Goltsman, G., Arakelyan, S., Evlyukhin, A., et al. (2019). Towards the fiber-optic Kennedy quantum receiver. In EPJ Web Conf. (Vol. 220, 03011 (1 to 2)).
Abstract: We consider practical aspects of using standard fiber-optic elements and superconducting nanowire single-photon detectors for the development of a practical quantum receiver based on the Kennedy scheme. Our receiver allows to discriminate two phase-modulated coherent states of light at a wavelength of 1.5 microns in continuous mode with bit rate 200 Kbit/s and error rate about two times below the standard quantum limit.
|
Manova, N. N., Smirnov, E. O., Korneeva, Y. P., Korneev, A. A., & Goltsman, G. N. (2019). Superconducting photon counter for nanophotonics applications. In J. Phys.: Conf. Ser. (Vol. 1410, 012147 (1 to 5)).
Abstract: We develop large area superconducting single-photon detector SSPD with a micron-wide strip suitable for free-space coupling or packaging with multi-mode optical fibres. The detector sensitive area is 20 μm in diameter. In near infrared (1330 nm wavelength) our SSPD exhibits above 30% detection efficiency with low dark counts and 45 ps timing jitter.
|
Polyakova, M., Semenov, A. V., Kovalyuk, V., Ferrari, S., Pernice, W. H. P., & Gol'tsman, G. N. (2019). Protocol of measuring hot-spot correlation length for SNSPDs with near-unity detection efficiency. IEEE Trans. Appl. Supercond., 29(5), 1–5.
Abstract: We present a simple quantum detector tomography protocol, which allows, without ambiguities, to measure the two-spot detection efficiency and extract the hot-spot interaction length of superconducting nanowire single photon detectors (SNSPDs) with unity intrinsic detection efficiency. We identify a significant parasitic contribution to the measured two-spot efficiency, related to an effect of the bias circuit, and find a way to rule out this contribution during data post-processing and directly in the experiment. From the data analysis for waveguide-integrated SNSPD, we find signatures of the saturation of the two-spot efficiency and hot-spot interaction length of order of 100 nm.
|
Elezov, M., Ozhegov, R., Goltsman, G., & Makarov, V. (2019). Countermeasure against bright-light attack on superconducting nanowire single-photon detector in quantum key distribution. Opt. Express, 27(21), 30979–30988.
Abstract: We present an active anti-latching system for superconducting nanowire single-photon detectors. We experimentally test it against a bright-light attack, previously used to compromise security of quantum key distribution. Although our system detects continuous blinding, the detector is shown to be partially blindable and controllable by specially tailored sequences of bright pulses. Improvements to the countermeasure are suggested.
|
Polyakova, M. I., Florya, I. N., Semenov, A. V., Korneev, A. A., & Goltsman, G. N. (2019). Extracting hot-spot correlation length from SNSPD tomography data. In J. Phys.: Conf. Ser. (Vol. 1410, 012166 (1 to 4)).
Abstract: We present data of quantum detector tomography for the samples specifically optimized for this problem. Using this method, we take results of hot-spot correlation length of 17 ± 2 nm.
|
Moshkova, M., Morozov, P., Divochiy, A., Vakhtomin, Y., & Smirnov, K. (2019). Large active area superconducting single photon detector. In J. Phys.: Conf. Ser. (Vol. 1410, 012139).
Abstract: We present development of large active area superconducting single-photon detectors well coupled with standard 50 μm-core multi-mode fiber. The sensitive area of the SSPD is patterned using the photon-number-resolving design and occupies an area of 40×40 μm2. Using this approach, we have obtained excellent specifications: system detection efficiency of 47% measured using a 900 nm laser and low dark count rate of 100 cps. The main advantages of the approach presented are a very short dead time of the detector of 22 ns and FWHM jitter value of about 130 ps.
|
Romanov, N. R., Zolotov, P. I., & Smirnov, K. V. (2019). Development of disordered ultra-thin superconducting vanadium nitride films. In Proc. 8th Int. Conf. Photonics and Information Optics (pp. 425–426).
Abstract: We present the results of development and research of superconducting vanadium nitride VN films ~10 nm thick having different level of disorder. It is showed that both silicon substrate temperature T sub in process of magnetron sputtering and total gas pressure P affect superconducting transition temperature of sputtered films and R 300 /R 20 ratio defining their level of disorder. VN films suitable for development of superconducting single-photon detectors on their basis are obtained.
|