Sergeev, A. V., & Livanov, D. V. (1993). Phonon renormalization of thermoelectric power of high-Tc materials. In M. Meissner, & R. O. Pohl (Eds.), Phonon Scattering in Condensed Matter VII. Springer Series in Solid-State Sciences (Vol. 112, pp. 204–205).
Abstract: Renormalization of thermoelectric power due to Nielsen — Taylor effect (interference between electron-phonon and electron- impurity interactions) is used for the explanation of the temperature dependence and sign of the thermopower in high-Tc materials. In the framework of the model the negative sign of TEP of untwinned YBa2Cu3O7−x crystal in a-direction observed by Howson et. al. is connected to the strong hole scattering via O-vacancies in chains.
|
Elezov, M. S., Ozhegov, R. V., Goltsman, G. N., Makarov, V., Vinogradov, E. A., Naumov, A. V., et al. (2017). Development of the experimental setup for investigation of latching of superconducting single-photon detector caused by blinding attack on the quantum key distribution system. In EPJ Web Conf. (Vol. 132, 01004 (1 to 2)).
Abstract: Recently bright-light control of the SSPD has been demonstrated. This attack employed a “backdoor” in the detector biasing scheme. Under bright-light illumination, SSPD becomes resistive and remains “latched” in the resistive state even when the light is switched off. While the SSPD is latched, Eve can simulate SSPD single-photon response by sending strong light pulses, thus deceiving Bob. We developed the experimental setup for investigation of a dependence on latching threshold of SSPD on optical pulse length and peak power. By knowing latching threshold it is possible to understand essential requirements for development countermeasures against blinding attack on quantum key distribution system with SSPDs.
|
Elezov, M. S., Ozhegov, R. V., Goltsman, G. N., & Makarov, V. (2017). Development of the experimental setup for investigation of latching of superconducting single-photon detector caused by blinding attack on the quantum key distribution system. In EPJ Web of Conferences (Vol. 132, 2).
Abstract: Recently bright-light control of the SSPD has been
demonstrated. This attack employed a “backdoor†in the detector biasing
scheme. Under bright-light illumination, SSPD becomes resistive and
remains “latched†in the resistive state even when the light is switched off.
While the SSPD is latched, Eve can simulate SSPD single-photon response
by sending strong light pulses, thus deceiving Bob. We developed the
experimental setup for investigation of a dependence on latching threshold
of SSPD on optical pulse length and peak power. By knowing latching
threshold it is possible to understand essential requirements for
development countermeasures against blinding attack on quantum key
distribution system with SSPDs.
|
Gershenzon, E. M., Gol’tsman, G. N., Sergeev, A., & Semenov, A. D. (1990). Picosecond response of YBaCuO films to electromagnetic radiation. In W. Gorzkowski, M. Gutowski, A. Reich, & H. Szymczak (Eds.), Proc. European Conf. High-Tc Thin Films and Single Crystals (pp. 457–462).
Abstract: Radiation-induced change of the resistance was studied in the resistive state of YBaCuO films. Electron-phonon relaxation time T h was determmed from direct ep measurements and analysis of quasistationary electron heating. Temperature dependence of That TS 40 K was found to – ep be T h.. T'. The resul ts show that ep detectors with the response time of few picosecond at nitrogen temperature can be realized.
|
Iomdina, E. N., Seliverstov, S., Sianosyan, A., Teplyakova, K., Rusova, A., & Goltsman, G. (2016). The prospects of using the radiation for the assessment of corneal and scleral hydration. In Acta Ophthalmol. (Vol. 94).
Abstract: Purpose
An adequate water balance (hydration extent) is one of the basic factors of normal eye function, including its external shells – the cornea and the sclera. THz systems creating images in reflected beams are likely to become ideal instruments of noninvasive testing of corneal and scleral hydration degree as THz radiation is highly sensitive to water content. The paper aims at studying the transmittance and reflectance spectra of the cornea and the sclera of rabbit and human eyes, as well as those of the whole rabbit eye, in the frequency range of 0.13–0.32 THz.
Methods
The experiments were carried out on 3 corneas and 3 rabbit scleras, 2 whole rabbit eyes, and 3 human healthy adult scleras using a specially developed THz system based on reliable and easy‐to‐use continuous wave sources: a backward‐wave oscillator and an avalanche transit‐time diode.
Results
The transmittance spectra of the cornea and the sclera and the dependence of the reflection coefficient of these tissues in THz range on water percentage content were determined. Comparison of the rabbit cornea hydrated from 73.2% to 76.3% concentration by mass demonstrated an approximately linear relationship between THz reflectivity and water concentration. The decrease of free water concentration by 1% leads to a drop of the reflectance coefficient by 13%. The parameters studied displayed noticeable differences between the sclera and the cornea of rabbits and between rabbit sclera and human sclera.
Conclusions
Preliminary results demonstrate that the proposed technique, based on continuous THz radiation, may be used to create a device for noninvasive testing of corneal and scleral hydration, which has good potential of wide‐scale practical application.
The work was supported by the Russian Foundation of Basic Research (grant No.15‐29‐03843)
|