Records |
Author |
Romanov, N. R.; Zolotov, P. I.; Vakhtomin, Y. B.; Divochiy, A. V.; Smirnov, K. V. |
Title |
Electron diffusivity measurements of VN superconducting single-photon detectors |
Type |
Conference Article |
Year |
2018 |
Publication |
J. Phys.: Conf. Ser. |
Abbreviated Journal |
J. Phys.: Conf. Ser. |
Volume |
1124 |
Issue |
|
Pages |
051032 |
Keywords |
SSPD, SNSPD, VN |
Abstract |
The research of ultrathin vanadium nitride (VN) films as a promising candidate for superconducting single-photon detectors (SSPD) is presented. The electron diffusivity measurements are performed for such devices. Devices that were fabricated out from 9.9 nm films had diffusivity coefficient of 0.41 cm2/s and from 5.4 nm – 0.54 cm2/s. Obtained values are similar to other typical SSPD materials. The diffusivity that increases along with decreasing of the film thickness is expected to allow fabrication of the devices with improved characteristics. Fabricated VN SSPDs showed prominent single-photon response in the range 0.9-1.55 µm. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1742-6588 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1229 |
Permanent link to this record |
|
|
|
Author |
Romanov, N. R.; Zolotov, P. I.; Smirnov, K. V. |
Title |
Development of disordered ultra-thin superconducting vanadium nitride films |
Type |
Conference Article |
Year |
2019 |
Publication |
Proc. 8th Int. Conf. Photonics and Information Optics |
Abbreviated Journal |
Proc. 8th Int. Conf. Photonics and Information Optics |
Volume |
|
Issue |
|
Pages |
425-426 |
Keywords |
VN films |
Abstract |
We present the results of development and research of superconducting vanadium nitride VN films ~10 nm thick having different level of disorder. It is showed that both silicon substrate temperature T sub in process of magnetron sputtering and total gas pressure P affect superconducting transition temperature of sputtered films and R 300 /R 20 ratio defining their level of disorder. VN films suitable for development of superconducting single-photon detectors on their basis are obtained. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
Russian |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
978-5-7262-2536-4 |
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
http://fioconf.mephi.ru/files/2018/12/FIO2019-Sbornik.pdf |
Approved |
no |
Call Number |
|
Serial |
1802 |
Permanent link to this record |
|
|
|
Author |
Rasulova, G. K.; Pentin, I. V.; Vakhtomin, Y. B.; Smirnov, K. V.; Khabibullin, R. A.; Klimov, E. A.; Klochkov, A. N.; Goltsman, G. N. |
Title |
Pulsed terahertz radiation from a double-barrier resonant tunneling diode biased into self-oscillation regime |
Type |
Journal Article |
Year |
2020 |
Publication |
J. Appl. Phys. |
Abbreviated Journal |
J. Appl. Phys. |
Volume |
128 |
Issue |
22 |
Pages |
224303 (1 to 11) |
Keywords |
HEB, resonant tunneling diode, RTD |
Abstract |
The study of the bolometer response to terahertz (THz) radiation from a double-barrier resonant tunneling diode (RTD) biased into the negative differential conductivity region of the I–V characteristic revealed that the RTD emits two pulses in a period of intrinsic self-oscillations of current. The bolometer pulse repetition rate is a multiple of the fundamental frequency of the intrinsic self-oscillations of current. The bolometer pulses are detected at two critical points with a distance between them being half or one-third of a period of the current self-oscillations. An analysis of the current self-oscillations and the bolometer response has shown that the THz photon emission is excited when the tunneling electrons are trapped in (the first pulse) and then released from (the second pulse) miniband states. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0021-8979 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1262 |
Permanent link to this record |
|
|
|
Author |
Ozhegov, R. V.; Smirnov, A. V.; Vakhtomin, Yu. B.; Smirnov, K. V.; Divochiy, A. V.; Goltsman, G. N. |
Title |
Ultrafast superconducting bolometer receivers for terahertz applications |
Type |
Abstract |
Year |
2009 |
Publication |
Proc. PIERS |
Abbreviated Journal |
Proc. PIERS |
Volume |
|
Issue |
|
Pages |
867 |
Keywords |
HEB |
Abstract |
The research by the group of Moscow State Pedagogical University into the hot-electron phenomena in thin superconducting films has led to the development of new types of detectors and their use both in fundamental and applied studies. In this paper, we present the results of testing the terahertz HEB receiver systems based on ultrathin (∼ 4 nm) NbN and MoRe detectors with a response time of 50 ps and 1 ns, respectively. We have developed three types of devices which differ in the way a terahertz signal is coupled to the detector and cover the following ranges: 0.3–3 THz, 0.1–30 THz and 25–70 THz. In the case of the receiving system optimized for 0.3–3 THz, the sensitive element (a strip of asuperconductor with planar dimensions of 0.2μm (length) by 1.7μm (width)) was integrated witha planar broadband log-spiral antenna. For additional focusing ofthe incident radiation a silicon hyperhemispherical lens was used. For the 0.1–30 THz receivingsystem, the sensitive element was patterned as parallel strips(2μm wide each) filling an area of 500×500μm2with a filling factor of 0.5. In the receivingsystem of this type we used direct coupling of the incident radiation to the sensitive element. Inthe 25–70 THz range (detector type 2/2a in Table 1) we used a square-shaped superconductingdetector with planar dimensions of 10×10μm2. Incident radiation was coupled to the detectorwith the use of a germanium hyperhemispherical lens.The response time of the above receiving systems is determined by the cooling rate of the hotelectrons in the film. That depends on the electron-phonon interaction time, which is less forultrathin NbN than in MoRe. |
Address |
Moscow, Russia |
Corporate Author |
|
Thesis |
|
Publisher |
The Electromagnetics Academy |
Place of Publication |
777 Concord Avenue, Suite 207 Cambridge, MA 02138 |
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1559-9450 |
ISBN |
978-1-934142-09-7 |
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
RPLAB @ sasha @ ozhegovultrafast |
Serial |
1022 |
Permanent link to this record |
|
|
|
Author |
Ozhegov, R. V.; Gorshkov, K. N.; Vachtomin, Y. B.; Smirnov, K. V.; Finkel, M. I.; Goltsman, G. N.; Kiselev, O. S.; Kinev, N. V.; Filippenko, L. V.; Koshelets, V. P. |
Title |
Terahertz imaging system based on superconducting heterodyne integrated receiver |
Type |
Conference Article |
Year |
2014 |
Publication |
Proc. THz and Security Applications |
Abbreviated Journal |
Proc. THz and Security Applications |
Volume |
|
Issue |
|
Pages |
113-125 |
Keywords |
SIS mixer, SIR, THz imaging |
Abstract |
The development of terahertz imaging instruments for security systems is on the cutting edge of terahertz technology. We are developing a THz imaging system based on a superconducting integrated receiver (SIR). An SIR is a new type of heterodyne receiver based on an SIS mixer integrated with a flux-flow oscillator (FFO) and a harmonic mixer which is used for phase-locking the FFO. Employing an SIR in an imaging system means building an entirely new instrument with many advantages compared to traditional systems.
In this project we propose a prototype THz imaging system using an 1 pixel SIR and 2D scanner. At a local oscillator frequency of 500 GHz the best noise equivalent temperature difference (NETD) of the SIR is 10 mK at an integration time of 1 s and a detection bandwidth of 4 GHz. The scanner consists of two rotating flat mirrors placed in front of the antenna consisting of a spherical primary reflector and an aspherical secondary reflector. The diameter of the primary reflector is 0.3 m. The operating frequency of the imaging system is 600 GHz, the frame rate is 0.1 FPS, the scanning area is 0.5 × 0.5 m2, the image resolution is 50 × 50 pixels, the distance from an object to the scanner was 3 m. We have obtained THz images with a spatial resolution of 8 mm and a NETD of less than 2 K. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
Springer Netherlands |
Place of Publication |
Dordrecht |
Editor |
Corsi, C.; Sizov, F. |
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
978-94-017-8828-1 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1368 |
Permanent link to this record |
|
|
|
Author |
Ozhegov, R. V.; Gorshkov, K. N.; Smirnov, K. V.; Gol’tsman, G. N.; Filippenko, L. V.; Koshelets, V. P. |
Title |
Terahertz imaging system based on superconducting integrated receiver |
Type |
Conference Article |
Year |
2010 |
Publication |
Proc. 2-nd Int. Conf. Terahertz and Microwave radiation: Generation, Detection and Applications |
Abbreviated Journal |
Proc. 2-nd Int. Conf. Terahertz and Microwave radiation: Generation, Detection and Applications |
Volume |
|
Issue |
|
Pages |
20-22 |
Keywords |
SIS mixer, SIR |
Abstract |
The development of terahertz imaging instruments for security systems is on the cutting edge of terahertz technology. We are developing a THz imaging system based on a superconducting integrated receiver (SIR). An SIR is a new type of heterodyne receiver based on an SIS mixer integrated with a flux-flow oscillator (FFO) and a harmonic mixer which is used for phase-locking the FFO. Developing an array of SIRs would allow obtaining amplitude and phase characteristics of incident radiation in the plane of the receiver. Employing an SIR in an imaging system means building an entirely new instrument with many advantages compare to traditional systems: i) high temperature resolution, comparable to the best results for incoherent receivers; ii) high spectral resolution allowing spectral analysis of various substances; iii) the local oscillator frequency can be varied to obtain images at different frequencies, effectively providing “color” images; iv) since a heterodyne receiver preserves the phase of the radiation, it is possible to construct 3D images. The paper presents a prototype THz imaging system using an 1 pixel SIR. We have studied the dependence of the noise equivalent temperature difference (NETD) on the integration time and also possible ways of achieving best possible sensitivity. An NETD of 13 mK was obtained with an integration time of 1 sec a detection bandwidth of 4 GHz at a local oscillator frequency of 520 GHz. An important advantage of an FFO is its wide operation range: 300-700 GHz. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
ozhegov2010terahertz |
Serial |
1397 |
Permanent link to this record |
|
|
|
Author |
Moshkova, M. A.; Morozov, P. V.; Antipov, A. V.; Vakhtomin, Y. B.; Smirnov, K. V. |
Title |
High-efficiency multi-element superconducting single-photon detector |
Type |
Conference Article |
Year |
2021 |
Publication |
Proc. SPIE |
Abbreviated Journal |
Proc. SPIE |
Volume |
11771 |
Issue |
|
Pages |
2-8 |
Keywords |
PNR SSPD, large active area, detection efficiency |
Abstract |
We present the result of the creation and investigation of the multi-element superconducting single photon detectors, which can recognize the number of photons (up to six) in a short pulse of the radiation at telecommunication wavelengths range. The best receivers coupled with single-mode fiber have the system quantum efficiency of ⁓85%. The receivers have a 100 ps time resolution and a few nanoseconds dead time that allows them to operate at megahertz counting rate. Implementation of the multi-element architecture for creation of the superconducting single photon detectors with increased sensitive area allows to create the high efficiency receivers coupled with multi-mode fibers and with preserving of the all advantages of superconducting photon counters. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
SPIE |
Place of Publication |
|
Editor |
Prochazka, I.; Štefaňák, M.; Sobolewski, R.; Gábris, A. |
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
Quantum Optics and Photon Counting |
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1795 |
Permanent link to this record |
|
|
|
Author |
Moshkova, M. A.; Divochiy, A. V.; Morozov, P. V.; Antipov, A. V.; Vakhtomin, Yu. B.; Smirnov, K. V. |
Title |
Characterization of topologies of superconducting photon number resolving detectors |
Type |
Conference Article |
Year |
2019 |
Publication |
Proc. 8th Int. Conf. Photonics and Information Optics |
Abbreviated Journal |
Proc. 8th Int. Conf. Photonics and Information Optics |
Volume |
|
Issue |
|
Pages |
465-466 |
Keywords |
PNR SSPD |
Abstract |
Comparative analysis for different topologies of superconducting single-photon detectors with ability to resolve up to 4 photons in a short pulse of IR radiation has been carry out. It was developed the detector with a system detection efficiency of ~ 85 % at λ = 1550 nm. The possibility of using such detector to restore photon statistics of a pulsed radiation source was demonstrated. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
Russian |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
978-5-7262-2536-4 |
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
http://fioconf.mephi.ru/files/2018/12/FIO2019-Sbornik.pdf |
Approved |
no |
Call Number |
|
Serial |
1803 |
Permanent link to this record |
|
|
|
Author |
Morozov, D. V.; Smirnov, K. V.; Smirnov, A. V.; Lyakhov, V. A.; Goltsman, G. N. |
Title |
A millimeter-submillimeter phonon-cooled hot-electron bolometer mixer based on two-dimensional electron gas in an AlGaAs/GaAs heterostructure |
Type |
Journal Article |
Year |
2005 |
Publication |
Semicond. |
Abbreviated Journal |
Semicond. |
Volume |
39 |
Issue |
9 |
Pages |
1082-1086 |
Keywords |
2D electron gas, AlGaAs/GaAs heterostructures, mixers |
Abstract |
Experimental results obtained by studying the main characteristics of a millimeter-submillimeter wave mixer based on the hot-electron effect in a two-dimensional electron gas in a AlGaAs/GaAs heterostructure with a phonon-scattering cooling mechanism for charge carriers are reported. The gain bandwidth of the mixer is 4 GHz, the internal conversion losses are 13 dB, and the optimum local-oscillator power is 0.5 μW (for a mixer area of 1 μm2). It is shown that a millimeter-submillimeter-wave receiver with a noise temperature of 1900 K can be developed on the basis of a AlGaAs/GaAs mixer. This mixer also appears to be promising for use in array receiver elements. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1063-7826 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1463 |
Permanent link to this record |
|
|
|
Author |
Maslennikov, S. N.; Morozov, D. V.; Ozhegov, R. V.; Smirnov, K. V.; Okunev, O. V.; Gol’tsman, G. N. |
Title |
Imaging system for submillimeter wave range based on AlGaAs/GaAs hot electron bolometer mixers |
Type |
Conference Article |
Year |
2004 |
Publication |
Proc. 5-th MSMW |
Abbreviated Journal |
Proc. 5-th MSMW |
Volume |
2 |
Issue |
|
Pages |
558-560 |
Keywords |
AlGaAs/GaAs HEB mixers |
Abstract |
Electromagnetic radiation of the submillimeter (SMM) range is dispersed and absorbed significantly less than infrared (IR) radiation when passing through different objects. That is the reason for the development of an SMM imaging system. In this paper, we discuss the design of an SMM heterodyne imager, based on a matrix of AlGaAs/GaAs heterostructure hot electron bolometer mixers (HEB) with relatively high (about 77 K) operating temperature. The predicted double side band (DSB) noise temperature is about 1000 K and optimal local oscillator (LO) power is about 1 /spl mu/W for such mixers, which seems to be quite prospective for an SMM heterodyne imager. |
Address |
Kharkov, Ukraine |
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
The Fifth International Kharkov Symposium on Physics and Engineering of Microwaves, Millimeter, and Submillimeter Waves (IEEE Cat. No.04EX828) |
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1487 |
Permanent link to this record |
|
|
|
Author |
Maslennikov, S. N.; Finkel, M. I.; Antipov, S. V.; Polyakov, S. L.; Zhang, W.; Ozhegov, R.; Vachtomin, Yu. B.; Svechnikov, S. I.; Smirnov, K. V.; Korotetskaya, Yu. P.; Kaurova, N. S.; Gol'tsman, G. N.; Voronov, B. M. |
Title |
Spiral antenna coupled and directly coupled NbN HEB mixers in the frequency range from 1 to 70 THz |
Type |
Conference Article |
Year |
2006 |
Publication |
Proc. 17th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 17th Int. Symp. Space Terahertz Technol. |
Volume |
|
Issue |
|
Pages |
177-179 |
Keywords |
directly coupled NbN HEB mixers |
Abstract |
We investigate both antenna coupled and directly coupled HEB mixers at several LO frequencies within the range of 2.5 THz to 70 THz. H20 (2.5+10.7 THz), and CO2 (30 THz) gas discharge lasers are used as the local oscillators. The noise temperature of antenna coupled mixers is measured at LO frequencies of 2.5 THz, 3.8 THz, and 30 THz. The results for both antenna coupled and directly coupled mixer types are compared. The devices with in—plane dimensions of 5x5 ,um 2 are pumped by LO radiation at 10.7 THz. The directly coupled HEB demonstrates nearly flat dependence of responsivity on frequency in the range of 25+64 THz. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Paris, France |
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
386 |
Permanent link to this record |
|
|
|
Author |
Lobanov, Y. V.; Vakhtomin, Y. B.; Pentin, I. V.; Rosental, V. A.; Smirnov, K. V.; Goltsman, G. N.; Volkov, O. Y.; Dyuzhikov, I. N.; Galiev, R. R.; Ponomarev, D. S.; Khabibullin, R. A. |
Title |
Time-resolved measurements of light–current characteristic and mode competition in pulsed THz quantum cascade laser |
Type |
Journal Article |
Year |
2021 |
Publication |
Optical Engineering |
Abbreviated Journal |
Optical Engineering |
Volume |
60 |
Issue |
8 |
Pages |
1-8 |
Keywords |
HEB, terahertz pulse generation, terahertz pulse detection, QCL, quantum cascade laser, superconducting hot electron bolometer |
Abstract |
Quantum cascade lasers (QCL) are widely adopted as prominent and easy-to-use solid-state sources of terahertz radiation. Yet some applications require generation and detection of very sharp and narrow terahertz-range pulses with a specific spectral composition. We have studied time-resolved light-current (L–I) characteristics of multimode THz QCL operated with a fast ramp of the injection current. Detection of THz pulses was carried out using an NbN superconducting hot-electron bolometer with the time constant of the order of 1 ns while the laser bias current was swept during a single driving pulse. A nonmonotonic behavior of the L–I characteristic with several visually separated subpeaks was found. This behavior is associated with the mode competition in THz QCL cavity, which we confirm by L–I measurements with use of an external Fabry–Perot interferometer for a discrete mode selection. We also have demonstrated the possibility to control the L–I shape with suppression of one of the subpeaks by simply adjusting the off-axis parabolic mirror for optimal optical alignment for one of the laser modes. The developed technique paves the way for rapid characterization of pulsed THz QCLs for further studies of the possibilities of using this approach in remote sensing. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
Spie |
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
10.1117/1.Oe.60.8.082019 |
Serial |
1260 |
Permanent link to this record |
|
|
|
Author |
Lobanov, Y. V.; Vakhtomin, Y. B.; Pentin, I. V.; Khabibullin, R. A.; Shchavruk, N. V.; Smirnov, K. V.; Silaev, A. A. |
Title |
Characterization of the THz quantum cascade laser using fast superconducting hot electron bolometer |
Type |
Journal Article |
Year |
2018 |
Publication |
EPJ Web Conf. |
Abbreviated Journal |
EPJ Web Conf. |
Volume |
195 |
Issue |
|
Pages |
04004 (1 to 2) |
Keywords |
NbN HEB, QCL |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
2100-014X |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
3rd International Conference “Terahertz and Microwave Radiation: Generation, Detection and Applications” (TERA-2018) |
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1808 |
Permanent link to this record |
|
|
|
Author |
Kuznetsov, K. A.; Kornienko, V. V.; Vakhtomin, Y. B.; Pentin, I. V.; Smirnov, K. V.; Kitaeva, G. K. |
Title |
Generation and detection of optical-terahertz biphotons via spontaneous parametric downconversion |
Type |
Conference Article |
Year |
2018 |
Publication |
Proc. ICLO |
Abbreviated Journal |
Proc. ICLO |
Volume |
|
Issue |
|
Pages |
303 |
Keywords |
NbN HEB applications |
Abstract |
We study spontaneous parametric downconversion (SPDC) in the strongly non-degenerate regime when the idler wave hits the terahertz range. By using the hot-electron bolometer, for the first time the SPDC-generated idler-wave photons were directly detected in the terahertz frequency range. Spectrum of corresponding signal photons was measured using standard technique by the CCD camera. Possible applications of correlated optical-terahertz biphotons are discussed. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
International Conference Laser Optics |
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1806 |
Permanent link to this record |
|
|
|
Author |
Korneeva, Yu. P.; Trifonov, A. V.; Vakhtomin, Yu. B.; Smirnov, K. V. |
Title |
Design of resonator for superconducting single-photon detector |
Type |
Journal Article |
Year |
2011 |
Publication |
Rus. J. Radio Electron. |
Abbreviated Journal |
Rus. J. Radio Electron. |
Volume |
|
Issue |
12 |
Pages |
|
Keywords |
SSPD optical resonator, SNSPD |
Abstract |
A resonator for superconducting single-photon detector is designed. Near 60% coupling with a radiation propagating from a dielectric substrate of optical fiber is demonstrated to be achieved for typical values of the detector’s film sheet resistance. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
Russian |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
6 pages |
Approved |
no |
Call Number |
|
Serial |
1827 |
Permanent link to this record |