|
Gousev, Y. P., Gol'tsman, G. N., Karasik, B. S., Gershenzon, E. M., Semenov, A. D., Barowski, H. S., et al. (1996). Quasioptical superconducting hot electron bolometer for submillmeter waves. Int. J. of Infrared and Millimeter Waves, 17(2), 317–331.
Abstract: We report on a superconducting hot electron bolometer coupled to radiation via a broadband antenna. The bolometer, a structured NbN film, was patterned on a thin dielectric membrane between terminals of a gold slotline antenna. We investigated the response to submillimeter radiation (wave-lengths ∼ 0.1 mm to 0.7 mm) in the fundamental Gaussian mode. We found that the directivity of the antenna was constant within a factor of 2.5 through the whole experimental range. The noise equivalent power of the bolometer at 119 µm was ∼ 3 · 10−13 W/Hz1/2; a time constant of ∼ 160 ps was estimated.
|
|
|
Słysz, W., Wegrzecki, M., Bar, J., Grabiec, P., Górska, M., Zwiller, V., et al. (2007). Fibre-coupled, single photon detector based on NbN superconducting nanostructures for quantum communications. J. Modern Opt., 54(2-3), 315–326.
Abstract: We present a novel, two-channel, single photon receiver based on two fibre-coupled, NbN, superconducting, single photon detectors (SSPDs). The SSPDs are nanostructured superconducting meanders and are known for ultrafast and efficient detection of visible-to-infrared photons. Coupling between the NbN detector and optical fibre was achieved using a micromechanical photoresist ring placed directly over the SSPD, holding the fibre in place. With this arrangement, we obtained coupling efficiencies up to ∼30%. Our experimental results showed that the best receiver had a near-infrared system quantum efficiency of 0.33% at 4.2 K. The quantum efficiency increased exponentially with the photon energy increase, reaching a few percent level for visible-light photons. The photoresponse pulses of our devices were limited by the meander high kinetic inductance and had the rise and fall times of approximately 250 ps and 5 ns, respectively. The receiver's timing jitter was in the 37 to 58 ps range, approximately 2 to 3 times larger than in our older free-space-coupled SSPDs. We stipulate that this timing jitter is in part due to optical fibre properties. Besides quantum communications, the two-detector arrangement should also find applications in quantum correlation experiments.
|
|
|
Gershenzon, E. M., Gurvich, Y. A., Orlova, S. L., & Ptitsina, N. G. (1975). Cyclotron resonance of electrons in Ge in a quantizing magnetic field in the case of inelastic scattering by acoustic phonons. Sov. Phys. JETP, 40(2), 311–315.
Abstract: Results are presented of an experimental study of the linewidth of cyclotron resonance under strong quantization conditions on the scattering of electrons by acoustic phonons. The measurements were performed in the 2....{).4 mm wavelength range at temperatures between 10 and 1.4 OK. A number of singularities were observed in the temperature and frequency dependences of the cyclotron linewidth. These can be ascribed to the effect of inhomogeneous broadening due to nonparabolicity of the electron spectrum, which is renormalized as a result of interaction with acoustic phonons.
|
|
|
Елманова, А., Елманов, И., Комракова, С., Голиков, А., Джавадзадэ, Д., Воробьёв, В., et al. (2019). Способ интеграции наноалмазов с нанофотонными устройствами из нитрида кремния. In Proc. IWQO (pp. 309–311).
Abstract: В работе были разработаны оптические структуры из нитрида кремния для дальнейшего размещения на них наноалмазов с NV-центрами, опробованы различные методики нанесения раствора наноалмазов и выбрана оптимальная. Работа имеет практическое значение в области нанофотоники и создании квантово-оптических устройств с однофотонными источниками.
|
|
|
Елманов, И. А., Елманова, А. В., Голиков, А. Д., Комракова, С. А., Каурова, Н. С., Ковалюк, В. В., et al. (2019). Способ определения параметров резистов для электронной литографии фотонных интегральных схем на платформе нитрида кремния. In Proc. IWQO (pp. 306–308).
Abstract: В работе были измерены толщины резистов ZEP 520A и ma-N 2400 для электронно-лучевой литографии, неразрушающим способом, а также подобран рецепт, обеспечивающий высокое отношение скорости травления нитрида кремния по сравнению с резистом. Работа имеет практическое значение для электронной литографии интегрально-оптических устройств и устройств нанофотоники на основе нитрида кремния.
|
|