|
Records |
Links |
|
Author |
Kovalyuk, V.; Ferrari, S.; Kahl, O.; Semenov, A.; Lobanov, Yu; Shcherbatenko, M.; Korneev, A; Pernice, W.; Goltsman, G. |
|
|
Title |
Waveguide integrated superconducting single-photon detector for on-chip quantum and spectral photonic application |
Type |
Conference Volume |
|
Year |
2017 |
Publication |
Proc. SPBOPEN |
Abbreviated Journal |
Proc. SPBOPEN |
|
|
Volume |
|
Issue |
|
Pages |
421-422 |
|
|
Keywords |
waveguide, SSPD, SNSPD |
|
|
Abstract |
By adopting a travelling-wave geometry approach, integrated superconductor- nanophotonic devices were fabricated. The architecture consists of a superconducting NbN- nanowire atop of a silicon nitride (Si 3 N 4 ) nanophotonic waveguide. NbN-nanowire was operated as a single-photon counting detector, with up to 92% on-chip detection efficiency (OCDE), in the coherent mode, serving as a highly sensitive IR heterodyne mixer with spectral resolution (f/df) greater than 10^6 in C-band at 1550 nm wavelength. |
|
|
Address |
St. Petersburg, Russia |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
Duplicated as 1140 |
Approved |
no |
|
|
Call Number |
|
Serial |
1256 |
|
Permanent link to this record |
|
|
|
|
Author |
Гершензон, Е. М.; Семенов, И. Т.; Фогельсон, М. С. |
|
|
Title |
О механизме динамического сужения линии ЭПР доноров фосфора в кремнии |
Type |
Journal Article |
|
Year |
1984 |
Publication |
Физика и техника полупроводников |
Abbreviated Journal |
Физика и техника полупроводников |
|
|
Volume |
18 |
Issue |
3 |
Pages |
421-425 |
|
|
Keywords |
Si, phosphorus donors, EPR |
|
|
Abstract |
Температурная зависимость ширины линии ЭПР доноров Р в Si исследована в интервале концентрации ND=2.5⋅1017−9⋅1017см−3 и температур T=1.7−45 K на образцах с различной степенью компенсации основной примеси. Результаты согласуются с моделью обменного сужения линии при учете температурной зависимости обменного интеграла и тем самым исключают предлагавшийся ранее механизм сужения линии вследствие прыжкового движения электронов по примесным центрам. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1761 |
|
Permanent link to this record |
|
|
|
|
Author |
Lobanov, Yury V.; Tong, Cheuk-yu E.; Hedden, Abigail S.; Blundell, Raymond; Gol’tsman, Gregory N. |
|
|
Title |
Microwave-assisted measurement of the frequency response of terahertz HEB mixers with a Fourier transform spectrometer |
Type |
Conference Article |
|
Year |
2010 |
Publication |
Proc. 21th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 21th Int. Symp. Space Terahertz Technol. |
|
|
Volume |
|
Issue |
|
Pages |
420-423 |
|
|
Keywords |
|
|
|
Abstract |
We describe a novel method of operation of the HEB direct detector for use with a Fourier Transform Spectrometer. Instead of elevating the bath temperature, we have measured the RF response of waveguide HEB mixers by applying microwave radiation to select appropriate bias conditions. In our experiment, a microwave signal is injected into the HEB mixer via its IF port. By choosing an appropriate injection level, the device can be operated close to the desired operating point. Furthermore, we have shown that both thermal biasing and microwave injection can reproduce the same spectral response of the HEB mixer. However, with the use of microwave injection, there is no need to wait for the mixer to reach thermal equilibrium, so characterisation can be done in less time. Also, the liquid helium consumption for our wet cryostat is also reduced. We have demonstrated that the signal- to-noise ratio of the FTS measurements can be improved with microwave injection. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1394 |
|
Permanent link to this record |
|
|
|
|
Author |
Gershenzon, E. M.; Gol'tsman, G. N.; Elantiev, A. I.; Karasik, B. S.; Potoskuev, S. E. |
|
|
Title |
Intense electromagnetic radiation heating of electrons of a superconductor in the resistive state |
Type |
Journal Article |
|
Year |
1988 |
Publication |
Sov. J. Low Temp. Phys. |
Abbreviated Journal |
Sov. J. Low Temp. Phys. |
|
|
Volume |
14 |
Issue |
7 |
Pages |
414-420 |
|
|
Keywords |
HEB |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
Duplicated as 1697 |
Approved |
no |
|
|
Call Number |
|
Serial |
236 |
|
Permanent link to this record |
|
|
|
|
Author |
Hajenius, M.; Baselmans, J. J. A.; Gao, J. R.; Klapwijk, T. M.; de Korte, P. A. J.; Voronov, B.; Gol’tsman, G. |
|
|
Title |
Improved NbN phonon cooled hot electron bolometer mixers |
Type |
Conference Article |
|
Year |
2003 |
Publication |
Proc. 14th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 14th Int. Symp. Space Terahertz Technol. |
|
|
Volume |
|
Issue |
|
Pages |
413-423 |
|
|
Keywords |
NbN HEB mixers |
|
|
Abstract |
NbN phonon-cooled hot electron bolometer mixers (HEBs) have been realized with negligible contact resistance to Au pads. By adding either a 5 nm Nb or a 10 nm NbTiN layer between the Au and NbN, to preserve superconductivity in the NbN under the Au contact pad, superior noise temperatures have been obtained. Using DC I,V curves and resistive transitions in combination with process parameters we analyze the nature of these improved devices and determine interface transparencies. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Tucson, USA |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
337 |
|
Permanent link to this record |