Gershenzon, E. M., Gol'tsman, G. N., Dzardanov, A. L., Elant'ev, A. I., Zorin, M. A., Markin, A. G., et al. (1992). S-N switching of niobium and YBCO films: limit time and perspective of fast key element creation. Sverkhprovodimost': Fizika, Khimiya, Tekhnika, 5(12), 2386–2402.
Abstract: A study was made on processes of switching of thin niobium film strips between superconducting and normal states under the effect of optical radiation pulse and voltage step. The results are described satisfactorily by the model of spatial homogeneous electron heating. It is shown that limiting switching times can be equal to several shares of nanosecond at 4.2 K. Preliminary results for YBa2Cu3O-7-x films are presented. Prospects and advantages of creation of ducting structures of narrow streps, are discussed.
|
|
|
Gershenzon, E. M., Gol'tsman, G. N., & Ptitsyna, N. G. (1977). Carrier lifetime in excited states of shallow impurities in germanium. JETP Lett., 25(12), 539–543.
|
|
|
Blagosklonskaya, L. E., Gershenzon, E. M., Gol'tsman, G. N., & Elant'ev, A. I. (1977). Effect of a high magnetic field on the spectrum of donors in InSb. Fizika i Tekhnika Poluprovodnikov, 11(12), 2373–2375.
|
|
|
Zhang, J., Boiadjieva, N., Chulkova, G., Deslandes, H., Gol'tsman, G. N., Korneev, A., et al. (2003). Noninvasive CMOS circuit testing with NbN superconducting single-photon detectors. Electron. Lett., 39(14), 1086–1088.
Abstract: The 3.5 nm thick-film, meander-structured NbN superconducting single-photon detectors have been implemented in the CMOS circuit-testing system based on the detection of near-infrared photon emission from switching transistors and have significantly improved the performance of the system. Photon emissions from both p- and n-MOS transistors have been observed.
|
|
|
Baselmans, J. J. A., Baryshev, A., Reker, S. F., Hajenius, M., Gao, J. R., Klapwijk, T. M., et al. (2005). Direct detection effect in small volume hot electron bolometer mixers. Appl. Phys. Lett., 86(16), 163503 (1 to 3).
Abstract: We measure the direct detection effect in a small volume (0.15μm×1μm×3.5nm)(0.15μm×1μm×3.5nm) quasioptical NbN phonon cooled hot electronbolometermixer at 1.6THz1.6THz. We find that the small signal sensitivity of the receiver is underestimated by 35% due to the direct detection effect and that the optimal operating point is shifted to higher bias voltages when using calibration loads of 300K300K and 77K77K. Using a 200GHz200GHzbandpass filter at 4.2K4.2K the direct detection effect virtually disappears. This has important implications for the calibration procedure of these receivers in real telescope systems.
|
|