|
Wampfler, S. F., Herczeg, G. J., Bruderer, S., Benz, A. O., van Dishoeck, E. F., Kristensen, L. E., et al. (2010). Herschel observations of the hydroxyl radical (OH) in young stellar objects. Astron. Astrophys., 521, L36.
Abstract: Aims. “Water In Star-forming regions with Herschel†(WISH) is a Herschel key program investigating the water chemistry in young stellar objects (YSOs) during protostellar evolution. Hydroxyl (OH) is one of the reactants in the chemical network most closely linked to the formation and destruction of H2O. High-temperature (T 250 K) chemistry connects OH and H2O through the OH + H2 H2O + H reactions. Formation of H2O from OH is efficient in the high-temperature regime found in shocks and the innermost part of protostellar envelopes. Moreover, in the presence of UV photons, OH can be produced from the photo-dissociation of H2O through H2O + γUV OH + H.
Methods. High-resolution spectroscopy of the 163.12 μm triplet of OH towards HH 46 and NGC 1333 IRAS 2A was carried out with the Heterodyne Instrument for the Far Infrared (HIFI) on board the Herschel Space Observatory. The low- and intermediate-mass protostars HH 46, TMR 1, IRAS 15398-3359, DK Cha, NGC 7129 FIRS 2, and NGC 1333 IRAS 2A were observed with the Photodetector Array Camera and Spectrometer (PACS) on Herschel in four transitions of OH and two [O i] lines.
Results. The OH transitions at 79, 84, 119, and 163 μm and [O i] emission at 63 and 145μm were detected with PACS towards the class I low-mass YSOs as well as the intermediate-mass and class I Herbig Ae sources. No OH emission was detected from the class 0 YSO NGC 1333 IRAS 2A, though the 119 μm was detected in absorption. With HIFI, the 163.12 μm was not detected from HH 46 and only tentatively detected from NGC 1333 IRAS 2A. The combination of the PACS and HIFI results for HH 46 constrains the line width (FWHM 11 km s-1) and indicates that the OH emission likely originates from shocked gas. This scenario is supported by trends of the OH flux increasing with the [O i] flux and the bolometric luminosity, as found in our sample. Similar OH line ratios for most sources suggest that OH has comparable excitation temperatures despite the different physical properties of the sources.
|
|
|
O'Neal, C. (2010). A project guide to rocks and minerals.
|
|
|
Семенов, А. В. (2010). Проскальзывание фазы, поглощение электромагнитного излучения и формирование отклика в детекторах на основе узких полосок сверхпроводников. Ph.D. thesis, , .
|
|
|
Lobanov, Y. V., Tong, C. -yu E., Hedden, A. S., Blundell, R., & Gol’tsman, G. N. (2010). Microwave-assisted measurement of the frequency response of terahertz HEB mixers with a Fourier transform spectrometer. In Proc. 21th Int. Symp. Space Terahertz Technol. (pp. 420–423).
Abstract: We describe a novel method of operation of the HEB direct detector for use with a Fourier Transform Spectrometer. Instead of elevating the bath temperature, we have measured the RF response of waveguide HEB mixers by applying microwave radiation to select appropriate bias conditions. In our experiment, a microwave signal is injected into the HEB mixer via its IF port. By choosing an appropriate injection level, the device can be operated close to the desired operating point. Furthermore, we have shown that both thermal biasing and microwave injection can reproduce the same spectral response of the HEB mixer. However, with the use of microwave injection, there is no need to wait for the mixer to reach thermal equilibrium, so characterisation can be done in less time. Also, the liquid helium consumption for our wet cryostat is also reduced. We have demonstrated that the signal- to-noise ratio of the FTS measurements can be improved with microwave injection.
|
|
|
Шангина, Е. Л., Смирнов, К. В., Морозов, Д. В., Ковалюк, В. В., Гольцман, Г. Н., Веревкин, А. А., et al. (2010). Концентрационная зависимость полосы преобразования смесителей субмиллиметрового диапазона на основе наноструктур AlGaAs/GaAs. Изв. РАН Сер. Физ., 74(1), 110–112.
Abstract: Методом субмиллиметровой спектроскопии с высоким временным разрешением при Т = 4.2 К измерена концентрационная зависимость полосы преобразования гетеродинного детектирования гетероструктур AlGaAs/GaAs с двумерным электронным газом. С увеличением концентрации двумерных электронов ns = (1.6–6.6) · 1011см-2 ширина полосы преобразования f3dB уменьшается от 245 до 145 МГц. В исследованной области концентраций наблюдается зависимость f3dB , обусловленная рассеянием электронов на деформационном потенциале акустических фононов и пьезоэлектрическим рассеянием.
|
|
|
Hanneke, D., Home, J. P., Jost, J. D., Amini, J. M., Leibfried, D., & Wineland, D. J. (2010). Realization of a programmable two-qubit quantum processor. Nat. Phys., 6(1), 13–16.
Abstract: The universal quantum computer is a device capable of simulating any physical system and represents a major goal for the field of quantum information science. In the context of quantum information, `universal' refers to the ability to carry out arbitrary unitary transformations in the system's computational space. Combining arbitrary single-quantum-bit (qubit) gates with an entangling two-qubit gate provides a set of gates capable of achieving universal control of any number of qubits, provided that these gates can be carried out repeatedly and between arbitrary pairs of qubits. Although gate sets have been demonstrated in several technologies, they have so far been tailored towards specific tasks, forming a small subset of all unitary operators. Here we demonstrate a quantum processor that can be programmed with 15 classical inputs to realize arbitrary unitary transformations on two qubits, which are stored in trapped atomic ions. Using quantum state and process tomography, we characterize the fidelity of our implementation for 160 randomly chosen operations. This universal control is equivalent to simulating any pairwise interaction between spin-1/2 systems. A programmable multiqubit register could form a core component of a large-scale quantum processor, and the methods used here are suitable for such a device.
|
|
|
Shangina, E. L., Smirnov, K. V., Morozov, D. V., Kovalyuk, V. V., Gol’tsman, G. N., Verevkin, A. A., et al. (2010). Concentration dependence of the intermediate frequency bandwidth of submillimeter heterodyne AlGaAs/GaAs nanostructures. Bull. Russ. Acad. Sci. Phys., 74(1), 100–102.
Abstract: The concentration dependence of the intermediate frequency bandwidth of heterodyne AlGaAs/GaAs detectors with 2D electron gas is measured using submillimeter spectroscopy with high time resolution at T= 4.2 K. The intermediate frequency bandwidth f3dBfalls from 245 to 145 MHz with increasing concentration of 2D electrons n s = (1.6-6.6) × 10[su11] cm-2. The dependence f3dB ≈ n s – 0.04±is observed in the studied concentration range; this dependence is determined by electron scattering by the deformation potential of acoustic phonons and piezoelectric scattering.
|
|
|
Lydersen, L., Wiechers, C., Wittmann, C., Elser, D., Skaar, J., & Makarov, V. (2010). Hacking commercial quantum cryptography systems by tailored bright illumination. Nat. Photon., 4(10), 686–689.
Abstract: The peculiar properties of quantum mechanics allow two remote parties to communicate a private, secret key, which is protected from eavesdropping by the laws of physics. So-called quantum key distribution (QKD) implementations always rely on detectors to measure the relevant quantum property of single photons. Here we demonstrate experimentally that the detectors in two commercially available QKD systems can be fully remote-controlled using specially tailored bright illumination. This makes it possible to tracelessly acquire the full secret key; we propose an eavesdropping apparatus built of off-the-shelf components. The loophole is likely to be present in most QKD systems using avalanche photodiodes to detect single photons. We believe that our findings are crucial for strengthening the security of practical QKD, by identifying and patching technological deficiencies.
|
|
|
Шангина, Е. Л., Смирнов, К. В., Морозов, Д. В., Ковалюк, В. В., Гольцман, Г. Н., Веревкин, А. А., et al. (2010). Полоса и потери преобразования полупроводникового смесителя с фононным каналом охлаждения двумерных электронов. Физика и техника полупроводников, 44(11), 1475–1478.
Abstract: Методом субмиллиметровой спектроскопии с высоким временным разрешением измерены температурная и концентрационная зависимости полосы преобразования смесителей терагерцового диапазона AlGaAs/GaAs на разогреве двумерных электронов с фононным каналом их охлаждения. Полоса преобразования на уровне 3 дБ (f3 dB) при 4.2 K при изменении концентрации ns варьируется в пределах 150-250 МГц в соответствии со степенным законом f3 dB propto ns-0.5, что соответствует доминирующему механизму рассеяния на пьезоэлектрических фононах. Минимальное значение коэффициента потерь преобразования полупроводникового смесителя достигается в структурах с высокой подвижностью носителей mu>3·105 см2/В·с при 4.2 K.
|
|
|
Zhang, W., Khosropanah, P., Gao, J. R., Kollberg, E. L., Yngvesson, K. S., Bansal, T., et al. (2010). Quantum noise in a terahertz hot electron bolometer mixer. Appl. Phys. Lett., 96(11), 111113–(1–3).
Abstract: We have measured the noise temperature of a single, sensitive superconducting NbN hot electron bolometer (HEB) mixer in a frequency range from 1.6 to 5.3 THz, using a setup with all the key components in vacuum. By analyzing the measured receiver noise temperature using a quantum noise (QN) model for HEB mixers, we confirm the effect of QN. The QN is found to be responsible for about half of the receiver noise at the highest frequency in our measurements. The beta-factor (the quantum efficiency of the HEB) obtained experimentally agrees reasonably well with the calculated value.
|
|