|
Wampfler, S. F., Herczeg, G. J., Bruderer, S., Benz, A. O., van Dishoeck, E. F., Kristensen, L. E., et al. (2010). Herschel observations of the hydroxyl radical (OH) in young stellar objects. Astron. Astrophys., 521, L36.
Abstract: Aims. “Water In Star-forming regions with Herschel†(WISH) is a Herschel key program investigating the water chemistry in young stellar objects (YSOs) during protostellar evolution. Hydroxyl (OH) is one of the reactants in the chemical network most closely linked to the formation and destruction of H2O. High-temperature (T 250 K) chemistry connects OH and H2O through the OH + H2 H2O + H reactions. Formation of H2O from OH is efficient in the high-temperature regime found in shocks and the innermost part of protostellar envelopes. Moreover, in the presence of UV photons, OH can be produced from the photo-dissociation of H2O through H2O + γUV OH + H.
Methods. High-resolution spectroscopy of the 163.12 μm triplet of OH towards HH 46 and NGC 1333 IRAS 2A was carried out with the Heterodyne Instrument for the Far Infrared (HIFI) on board the Herschel Space Observatory. The low- and intermediate-mass protostars HH 46, TMR 1, IRAS 15398-3359, DK Cha, NGC 7129 FIRS 2, and NGC 1333 IRAS 2A were observed with the Photodetector Array Camera and Spectrometer (PACS) on Herschel in four transitions of OH and two [O i] lines.
Results. The OH transitions at 79, 84, 119, and 163 μm and [O i] emission at 63 and 145μm were detected with PACS towards the class I low-mass YSOs as well as the intermediate-mass and class I Herbig Ae sources. No OH emission was detected from the class 0 YSO NGC 1333 IRAS 2A, though the 119 μm was detected in absorption. With HIFI, the 163.12 μm was not detected from HH 46 and only tentatively detected from NGC 1333 IRAS 2A. The combination of the PACS and HIFI results for HH 46 constrains the line width (FWHM 11 km s-1) and indicates that the OH emission likely originates from shocked gas. This scenario is supported by trends of the OH flux increasing with the [O i] flux and the bolometric luminosity, as found in our sample. Similar OH line ratios for most sources suggest that OH has comparable excitation temperatures despite the different physical properties of the sources.
|
|
|
O'Neal, C. (2010). A project guide to rocks and minerals.
|
|
|
Shangina, E. L., Smirnov, K. V., Morozov, D. V., Kovalyuk, V. V., Gol’tsman, G. N., Verevkin, A. A., et al. (2010). Frequency bandwidth and conversion loss of a semiconductor heterodyne receiver with phonon cooling of two-dimensional electrons. Semicond., 44(11), 1427–1429.
Abstract: The temperature and concentration dependences of the frequency bandwidth of terahertz heterodyne AlGaAs/GaAs detectors based on hot electron phenomena with phonon cooling of two-dimensional electrons have been measured by submillimeter spectroscopy with a high time resolution. At a temperature of 4.2 K, the frequency bandwidth at a level of 3 dB (f 3 dB) is varied from 150 to 250 MHz with a change in the concentration n s according to the power law f 3dB ∝ n −0.5 s due to the dominant contribution of piezoelectric phonon scattering. The minimum conversion loss of the semiconductor heterodyne detector is obtained in structures with a high carrier mobility (μ > 3 × 105 cm2 V−1 s−1 at 4.2 K).
|
|
|
Shangina, E. L., Smirnov, K. V., Morozov, D. V., Kovalyuk, V. V., Gol’tsman, G. N., Verevkin, A. A., et al. (2010). Concentration dependence of the intermediate frequency bandwidth of submillimeter heterodyne AlGaAs/GaAs nanostructures. Bull. Russ. Acad. Sci. Phys., 74(1), 100–102.
Abstract: The concentration dependence of the intermediate frequency bandwidth of heterodyne AlGaAs/GaAs detectors with 2D electron gas is measured using submillimeter spectroscopy with high time resolution at T= 4.2 K. The intermediate frequency bandwidth f3dBfalls from 245 to 145 MHz with increasing concentration of 2D electrons n s = (1.6-6.6) × 10[su11] cm-2. The dependence f3dB ≈ n s – 0.04±is observed in the studied concentration range; this dependence is determined by electron scattering by the deformation potential of acoustic phonons and piezoelectric scattering.
|
|
|
Maingault, L., Tarkhov, M., Florya, I., Semenov, A., Espiau de Lamaëstre, R., Cavalier, P., et al. (2010). Spectral dependency of superconducting single photon detectors. J. Appl. Phys., 107(11), 116103 (1 to 3).
Abstract: We investigate the effect of varying both incoming optical wavelength and width of NbN nanowires on the superconducting single photon detectors (SSPD) detection efficiency. The SSPD are current biased close to critical value and temperature fixed at 4.2 K, far from transition. The experimental results are found to verify with a good accuracy predictions based on the “hot spot model,” whose size scales with the absorbed photon energy. With larger optical power inducing multiphoton detection regime, the same scaling law remains valid, up to the three-photon regime. We demonstrate the validity of applying a limited number of measurements and using such a simple model to reasonably predict any SSPD behavior among a collection of nanowire device widths at different photon wavelengths. These results set the basis for designing efficient single photon detectors operating in the infrared (2–5 μm range).
This work was supported by European projects FP6 STREP “SINPHONIA” (Contract No. NMP4-CT-2005-16433) and IP “QAP” (Contract No. 15848).
|
|
|
Lobanov, Y. V., Tong, C. -yu E., Hedden, A. S., Blundell, R., & Gol’tsman, G. N. (2010). Microwave-assisted measurement of the frequency response of terahertz HEB mixers with a Fourier transform spectrometer. In Proc. 21th Int. Symp. Space Terahertz Technol. (pp. 420–423).
Abstract: We describe a novel method of operation of the HEB direct detector for use with a Fourier Transform Spectrometer. Instead of elevating the bath temperature, we have measured the RF response of waveguide HEB mixers by applying microwave radiation to select appropriate bias conditions. In our experiment, a microwave signal is injected into the HEB mixer via its IF port. By choosing an appropriate injection level, the device can be operated close to the desired operating point. Furthermore, we have shown that both thermal biasing and microwave injection can reproduce the same spectral response of the HEB mixer. However, with the use of microwave injection, there is no need to wait for the mixer to reach thermal equilibrium, so characterisation can be done in less time. Also, the liquid helium consumption for our wet cryostat is also reduced. We have demonstrated that the signal- to-noise ratio of the FTS measurements can be improved with microwave injection.
|
|
|
Zinoni, C., Alloing, B., Li, L. H., Marsili, F., Fiore, A., Lunghi, L., et al. (2010). Erratum: “Single photon experiments at telecom wavelengths using nanowire superconducting detectors” [Appl. Phys. Lett. 91, 031106 (2007)]. Appl. Phys. Lett., 96(8), 089901.
Abstract: A calculation error was made in the original publication of this letter. The error was in the calculation of the noise equivalent power (NEP) values for the avalanche photodiode detector (APD) and the superconducting single photon detector (SSPD), the incorrect values were plotted on the right axis in Fig. 1(b). The correct NEP values were calculated with the same equation reported in the original letter and the revised Fig. 1(b) is shown below. The other conclusions of the paper remain unaltered.
|
|
|
Шангина, Е. Л., Смирнов, К. В., Морозов, Д. В., Ковалюк, В. В., Гольцман, Г. Н., Веревкин, А. А., et al. (2010). Концентрационная зависимость полосы преобразования смесителей субмиллиметрового диапазона на основе наноструктур AlGaAs/GaAs. Изв. РАН Сер. Физ., 74(1), 110–112.
Abstract: Методом субмиллиметровой спектроскопии с высоким временным разрешением при Т = 4.2 К измерена концентрационная зависимость полосы преобразования гетеродинного детектирования гетероструктур AlGaAs/GaAs с двумерным электронным газом. С увеличением концентрации двумерных электронов ns = (1.6–6.6) · 1011см-2 ширина полосы преобразования f3dB уменьшается от 245 до 145 МГц. В исследованной области концентраций наблюдается зависимость f3dB , обусловленная рассеянием электронов на деформационном потенциале акустических фононов и пьезоэлектрическим рассеянием.
|
|
|
Смирнов, К. В., Вахтомин, Ю. Б., Смирнов, А. В., Ожегов, Р. В., Пентин, И. В., Дивочий, А. В., et al. (2010). Приемники терагерцового и инфракрасного диапазонов, основанные на тонкопленочных сверхпроводниковых наноструктурах. Вестник НГУ. Серия: Физика, 5(4).
Abstract: В работе представлены результаты разработки и создания чувствительных и ультрабыстрых приемников, основанных на тонкопленочных сверхпроводниковых наноструктурах: болометрах на эффекте электронного разогрева (HEB – hot-electron bolometer) и детекторах одиночных фотонов видимого и инфракрасного диапазонов волн (SSPD – superconducting singe-photon detector). Представлены основные принципы работы сверхпроводниковых устройств, технология создания и конструкционные особенности приемников, их основные типы и характеристики. Достигнутые рекордные значения параметров приемных систем позволяют использовать созданные приборы при решении различных научно-исследовательских задач в ближнем, среднем и дальнем ИК диапазонах волн.
This work presents the results of the development and fabrication of sensitive and ultrafast detectorsbased on thin film superconducting nanostructures: hot-electron bolometers (HEBs) and visible and infrared superconducting singe photon detectors (SSPDs). The main operational principles of the superconducting devices are presentedas well as the technology of fabrication of the detectors and their main types and parameters. The achieved record parameters of the detectors allow application of the fabricated devices to solution of various research problems in the near, middle and far IR ranges.
|
|
|
Семенов, А. В. (2010). Проскальзывание фазы, поглощение электромагнитного излучения и формирование отклика в детекторах на основе узких полосок сверхпроводников. Ph.D. thesis, , .
|
|