Гершензон, Е. М., Гольцман, Г. Н., Елантьев, А. И., Кагане, М. Л., Мултановский, В. В., & Птицина, Н. Г. (1983). Применение субмиллиметровой ЛОВ спектроскопии для определения химической природы и концентрации примесей в чистых полупроводниках. Физика и техника полупроводников, 17(8), 1430–1437.
|
|
|
Gershenzon, E. M., Gol'tsman, G. N., & Semenov, A. D. (1983). Submillimeter backward wave tube spectrometer for measuring superconducting film transmission. Pribory i Tekhnika Eksperimenta, 26(5), 134–137.
Abstract: A spectrometer employing six backward wave tubes is described. It is intended for investigation of superconductors in the 0.2-3 mm range of wave lengths. During the measurement of the transmission spectrum it is possible to determine the energy gap for superconduct1ng films 50 to 4000 A thick. The transmission factor can vary from 10-1 to 10-9. Spectrum of relation of film transmission factors in superconducting and normal states is measured for determining the energy gap 2 Δ. The transmission spectrum obtained by means of a computer for vanadium film 300 A thick is given as an example. The energy gap 2 Δ = 1.4 MeV
|
|
|
Blagosklonskaya, L. E., Gershenzon, E. M., Gol'tsman, G. N., & Elant'ev, A. I. (1977). Effect of a high magnetic field on the spectrum of donors in InSb. Fizika i Tekhnika Poluprovodnikov, 11(12), 2373–2375.
|
|
|
Pentin, I., Finkel, M., Maslennikov, S., Vakhtomin, Y., Smirnov, K., Kaurova, N., et al. (2017). Superconducting hot-electron-bolometer mixers for the mid-IR. Rus. J. Radio Electron., (10), http://jre.cplire.ru/jre/oct17/9/text.pdf. Retrieved September 24, 2024, from http://jre.cplire.ru/jre/oct17/9/abstract_e.html
Abstract: The work presents the result of development of the NbN superconducting hot-electron-bolometer (HEB) mixer. The sensitive element of the mixer is directly coupled to mid-IR radiation, and doesn’t have planar metallic antenna. Investigations of noise characteristics of NbN HEB mixer were performed at the frequency 28.4 THz (λ = 10.6 µm) by using gas-discharge CW CO2-laser without consideration of optical and electrical losses in the heterodyne receiver. The noise temperature of NbN HEB mixer with the size of the sensitive element 10 µm × 10 µm was 2320 K (~ 1.5hν/kB) at the heterodyne frequency of 28.4 THz. The noise temperature was determined by measuring the Y-factor taking into account the term which describes fluctuations of zero-point oscillations in accordance with the fluctuation-dissipation theorem of Calle-Welton. Isothermal method was used to estimate the absorbed heterodyne radiation power which was 9 µW at the optimal operating point for the minimum noise temperature of NbN HEB mixer.
|
|
|
Гершензон, Е. М., Грачев, С. А., & Литвак-Горская, Л. Б. (1991). Механизм преобразования частоты в n-InSb-смесителе. Физика и техника полупроводников, 25(11), 1986–1998.
Abstract: Проведено комплексное исследование n-InSb смесителя на λ=2.6 мм, включающее в себя исследование вольт-амперных характеристик при E=0−2 В/см, температурной зависимости проводимости в диапазоне T=1.6−20 K, высокочастотной проводимости при f=0.5−10 МГц и магнитосопротивления при H=0−5 кЭ. Показано, что в оптимальном режиме механизм преобразования частоты связан с фотоионизационными процессами при прыжковой фотопроводимости (ПФП). На основе модели ПФП рассчитан коэффициент преобразования смесителя и произведено сопоставление его с экспериментом. Показана несостоятельность модели преобразования частоты в компенсированном n-InSb (K≥0.8), основанной на разогреве электронов. Обсуждены требования к параметрам материала и режимам n-InSb смесителя миллиметрового диапазона волн.
|
|