|
Carlstrom, J. E., & Jonas Zmuidzinas. (1996). Millimeter and Submillimeter Techniques. (848). Review of radio science 1993–1996, (34). New York: Oxford University Press Inc.
|
|
|
-. (1996). ГОСТ Р 15.011-96. Патентные исследования. Содержание и порядок проведения.
|
|
|
(1996). ГОСТ Р 50995.3.1-96. Технологическое обеспечение создания продукции. Технологическая подготовка производства.
|
|
|
Gousev, Y. P., Semenov, A. D., Pechen, E. V., Varlashkin, A. V., Nebosis, R. S., & Renk K. F. (1996). Coupling of terahertz radiation to a high-Т(с) superconducting hot electron bolometer mixer. Appl. Phys. Lett.,, 69, 691–693.
Abstract: We report on efficient coupling of THz radiation to a high-T(c) superconducting hot electron bolometer that is suitable for heterodyne detection. Our quasioptical system consisted of a planar self-complementary spiral antenna on a dielectric substrate clamped to an extended hyperhemispherical lens. The antenna was integrated into a co-planar line for broadband intermediate frequency matching. Measurements in the homodyne regime at a frequency of 2.5 THz showed a radiation pattern with a beam width of 1° and a coupling efficiency of 0.1. We measured, at an intermediate frequency of 1.5 GHz, an output noise temperature of'160 K and estimated for the device, operated in the heterodyne regime, a system noise temperature of 30 000 K. We also discuss possibilities of significant improvement of the sensitivity.
|
|
|
Dickert, F. L., Haunschild, A., Kuschow, V., Reif, M., & Stathopulos, H. (1996). Mass-sensitive detection of solvent vapors. Mechanistic studies on host-guest sensor principles by FT-IR spectroscopy and BET adsorption analysis. Anal. Chem., 68(6), 1058–1061.
Abstract: Chemical sensors, based on highly mass sensitive QMB or SAW devices, coated with thin layers of calixarenes, enable the detection of organic solvent vapours, especially halogenated or aromatic hydrocarbons, down to a few ppm. Force field calculations allow the tailoring of these sensor materials seeing that the predicted interaction energies between the host molecules and a large variety of analytes are linearly correlated to the measured sensor effects. These correlations and also BET adsorption analysis prove the analyte recognition properties of these calixarene coatings to be mainly based on host/guest inclusion principles.
Keywords: supramolecular recognition, quartz crystal microbalance, QCM, surface acoustic wave, SAW, mass-sensitive sensor, detector, calixarenes, MM3 force field, Brunauer, Emmett and Teller theory, BET
|
|
|
Semenov, A. D., Gousev, Y. P., Nebosis, R. S., Renk, K. F., Yagoubov, P., Voronov, B. M., et al. (1996). Heterodyne detection of THz radiation with a superconducting hot‐electron bolometer mixer. Appl. Phys. Lett., 69(2), 260–262.
Abstract: We report on the use of a superconducting hot‐electron bolometer mixer for heterodyne detection of terahertz radiation. Radiation with a wavelength of 119 μm was coupled to the mixer, a NbN microbridge, by a hybrid quasioptical antenna consisting of an extended hyperhemispherical lens and a planar logarithmic spiral antenna. We found, at an intermediate frequency of 1.5 GHz, a system double side band noise temperature of ≊40 000 K and conversion losses of 25 dB. We also discuss the possibilities of further improvement of the mixer performance.
|
|
|
Trifonov, V. A., Karasik, B. S., Zorin, M. A., Gol’tsman, G. N., Gershenzon, E. M., Lindgren, M., et al. (1996). 9.6 μm wavelength mixing in a patterned YBa2Cu3O7‐δ thin film. Appl. Phys. Lett., 68(10), 1418–1420.
Abstract: Hot‐electron bolometric (HEB) mixing of 9.6 μm infrared radiation from two lasers in high‐quality YBa2Cu3O7−δ (YBCO) patterned thin film has been demonstrated. A heterodyne measurement showed an intermediate frequency (IF) bandwidth of 18 GHz, limited by our measurement system. An intrinsic limit of 100 GHz is predicted. Between 0.1 and 1 GHz intermediate frequency, temperature fluctuations with an equivalent output noise temperature Tfl up to ∼150 K, contributed to the mixer noise while Johnson noise dominated above 1 GHz. The overall conversion loss at 77 K at low intermediate frequencies was measured to be ∼25 dB, of which 13 dB was due to the coupling loss. The HEB mixer is very promising for use in heterodyne receivers within the whole infrared range.
|
|
|
Karasik, B. S., & Elantiev, A. I. (1996). Noise temperature limit of a superconducting hot-electron bolometer mixer. Appl. Phys. Lett., 68(6), 853–855.
|
|
|
Karasik, B. S., Il'in, K. S., Pechen, E. V., & Krasnosvobodtsev, S. I. (1996). Diffusion cooling mechanism in a hot-electron NbC microbolometer mixer. Appl. Phys. Lett., 68(16), 2285–2287.
|
|
|
Chulcova, G. M., Ptitsina, N. G., Gershenzon, E. M., Gershenzon, M. E., & Sergeev, A. V. (1996). Effect of the interference between electron-phonon and electron-impurity (boundary) scattering on resistivity Nb, Al, Be films. In Czech J. Phys. (Vol. 46, pp. 2489–2490).
Abstract: The temperature dependence of the resistivity of thin Nb, Al, Be films has been studied over a wide temperature range 4-300 K. We have found that the temperature-dependent correction to the residual resistivity is well described by the sum of the Bloch-Grüneisen term and the term originating from the interference between electron-phonon and electron-impurity scattering. Study of the transport interference phenomena allows to determine electron-phonon coupling in disordered metals. The interference term is proportional to T2 and also to the residual resistivity and dominates over the Bloch-Grüneisen term at low temperatures (T<40 K).
|
|