|
Zhang, W., Miao, W., Yao, Q. J., Lin, Z. H., Shi, S. C., Gao, J. R., et al. (2012). Spectral response and noise temperature of a 2.5 THz spiral antenna coupled NbN HEB mixer. Phys. Procedia, 36, 334–337.
Abstract: We report on a 2.5 THz spiral antenna coupled NbN hot electron bolometer (HEB) mixers, fabricated with in-situ process. The receiver noise temperature with lowest value of 1180 K is in good agreement with calculated quantum efficiency factor as a function of bias voltage. In addition, the measured spectral response of the spiral antenna coupled NbN HEB mixer shows broad frequency coverage of 0.8-3 THz, and corrected response for optical losses, FTS, and coupling efficiency between antenna and bolometer falls with frequency due to diffraction-limited beam of lens/antenna combination.
|
|
|
Julia Toussaint, R. G., Marco Schubert, Torsten May, Hans-Georg Meyer, Benjamin Dietzek, Jürgen Popp, Matthias Hofherr, Matthias Arndt, Dagmar Henrich, Konstantin Il'in, and Michael Siegel. (2012). Superconducting single-photon counting system for optical experiments requiring time-resolution in the picosecond range. AIP REVIEW OF SCIENTIFIC INSTRUMENTS, 83.
Abstract: We have developed a cryogenic measurement system for single-photon counting, which can be used
in optical experiments requiring high time resolution in the picosecond range. The system utilizes
niobium nitride superconducting nanowire single-photon detectors which are integrated in a timecorrelated
single-photon counting (TCSPC) setup. In this work, we describe details of the mechanical
design, the electrical setup, and the cryogenic optical components. The performance of the complete
system in TCSPC mode is tentatively benchmarked using 140 fs long laser pulses at a repetition
frequency of 75MHz. Due to the high temporal stability of these pulses, the measured time resolution
of 35 ps (FWHM) is limited by the timing jitter of the measurement system. The result was crosschecked
in a Coherent Anti-stokes Raman Scattering (CARS) setup, where scattered pulses from a
β-barium borate crystal have been detected with the same time resolution.
|
|
|
Mineev, V. P. (2012). Superfluid helium: Order in disorder. Nat. Phys., 8, 253–254.
Abstract: Confining liquid 3He in porous silica aerogel prepared with strong anisotropy stabilizes a state of axial superfluidity.
|
|
|
Pütz, P., Honingh, C. E., Jacobs, K., Justen, M., Schultz, M., & Stutzki, J. (2012). Terahertz hot electron bolometer waveguide mixers for GREAT. A&A, 542, L2.
Abstract: Context. Supplementing the publications based on the first-light observations with the German REceiver for Astronomy at Terahertz frequencies (GREAT) on SOFIA, we present background information on the underlying heterodyne detector technology. This Letter complements the GREAT instrument Letter and focuses on the mixers itself.
Aims. We describe the superconducting hot electron bolometer (HEB) detectors that are used as frequency mixers in the L1 (1400 GHz), L2 (1900 GHz), and M (2500 GHz) channels of GREAT. Measured performance of the detectors is presented and background information on their operation in GREAT is given.
Methods. Our mixer units are waveguide-based and couple to free-space radiation via a feedhorn antenna. The HEB mixers are designed, fabricated, characterized, and flight-qualified in-house. We are able to use the full intermediate frequency bandwidth of the mixers using silicon-germanium multi-octave cryogenic low-noise amplifiers with very low input return loss.
Results. Superconducting HEB mixers have proven to be practical and sensitive detectors for high-resolution THz frequency spectroscopy on SOFIA. We show that our niobium-titanium-nitride (NbTiN) material HEBs on silicon nitride (SiN) membrane substrates have an intermediate frequency (IF) noise roll-off frequency above 2.8 GHz, which does not limit the current receiver IF bandwidth. Our mixer technology development efforts culminate in the first successful operation of a waveguide-based HEB mixer at 2.5 THz and deployment for radioastronomy. A significant contribution to the success of GREAT is made by technological development, thorough characterization and performance optimization of the mixer and its IF interface for receiver operation on SOFIA. In particular, the development of an optimized mixer IF interface contributes to the low passband ripple and excellent stability, which GREAT demonstrated during its initial successful astronomical observation runs.
|
|
|
Smirnov, A. V., Karmantsov, M. S., Smirnov, K. V., Vakhtomin, Y. B., Masterov, D. V., Tarkhov, M. A., et al. (2012). Terahertz response of thin-film YBCO bolometers. Tech. Phys., 57(12), 1716–1719.
Abstract: The bolometric response of high-temperature thin-film YBCO superconducting detectors to an electromagnetic radiation with a frequency of 2.5 THz is measured for the first time. The minimum value of the noise-equivalent power of the detectors is 3.5 × 10−9 W/Hz−−−√. The feasibility of further increasing the sensitivity of the detectors is discussed.
|
|
|
Akalin, T. (2012). Terahertz sources: Powerful photomixers. Nat. Photon., 6(2), 81.
Abstract: An efficient continuous-wave source of terahertz radiation that combines the outputs from two near-infrared semiconductor lasers in a novel photomixer looks set to benefit applications in spectroscopy and imaging.
|
|
|
Smirnov, A. V., Baryshev, A. M., de Bernardis, P., Vdovin, V. F., Gol'tsman, G. N., Kardashev, N. S., et al. (2012). The current stage of development of the receiving complex of the millimetron space observatory. Radiophys. Quant. Electron., 54(8), 557–568.
Abstract: We present an overview of the state of the onboard receiving complex of the Millimetron space observatory in the development phase of its preliminary design. The basic parameters of the onboard equipment planned to create and required for astrophysical observations are considered. A review of coherent and incoherent detectors, which are central to each receiver of the observatory, is given. Their characteristics and limiting parameters feasible at the present level of technology are reported.
|
|
|
Pris, A. D., Utturkar, Y., Surman, C., Morris, W. G., Vert, A., Zalyubovskiy, S., et al. (2012). Towards high-speed imaging of infrared photons with bio-inspired nanoarchitectures. Nat. Photon., 6(3), 195–200.
Abstract: Existing infrared detectors rely on complex microfabrication and thermal management methods. Here, we report an attractive platform of low-thermal-mass resonators inspired by the architectures of iridescent Morpho butterfly scales. In these resonators, the optical cavity is modulated by its thermal expansion and refractive index change, resulting in `wavelength conversion' of mid-wave infrared (3-8 µm) radiation into visible iridescence changes. By doping Morpho butterfly scales with single-walled carbon nanotubes, we achieved mid-wave infrared detection with 18-62 mK noise-equivalent temperature difference and 35-40 Hz heat-sink-free response speed. The nanoscale pitch and the extremely small thermal mass of individual `pixels' promise significant improvements over existing detectors. Computational analysis explains the origin of this thermal response and guides future conceptually new bio-inspired thermal imaging sensor designs.
|
|
|
Nozaki, K., Shinya, A., Matsuo, S., Suzaki, Y., Segawa, T., Sato, T., et al. (2012). Ultralow-power all-optical RAM based on nanocavities. Nat. Photon., 6(4), 248–252.
Abstract: Optical random-access memory (o-RAM) has been regarded as one of the most difficult challenges in terms of replacing its various functionalities in electronic circuitry with their photonic counterparts. Nevertheless, it constitutes a key device in optical routing and processing. Here, we demonstrate that photonic crystal nanocavities with an ultrasmall buried heterostructure design can solve most of the problems encountered in previous o-RAMs. By taking advantage of the strong confinement of photons and carriers and allowing heat to escape efficiently, we have realized all-optical RAMs with a power consumption of only 30 nW, which is more than 300 times lower than the previous record, and have achieved continuous operation. We have also demonstrated their feasibility in multibit integration. This paves the way for constructing a low-power large-scale o-RAM system that can handle high-bit-rate optical signals.
|
|
|
Knee, G. C., Simmons, S., Gauger, E. M., Morton, J. J. L., Riemann, H., Abrosimov, N. V., et al. (2012). Violation of a Leggett–Garg inequality with ideal non-invasive measurements. Nat. Comm., 3(606), 6.
Abstract: The quantum superposition principle states that an entity can exist in two different states simultaneously, counter to our 'classical' intuition. Is it possible to understand a given system's behaviour without such a concept? A test designed by Leggett and Garg can rule out this possibility. The test, originally intended for macroscopic objects, has been implemented in various systems. However to date no experiment has employed the 'ideal negative result' measurements that are required for the most robust test. Here we introduce a general protocol for these special measurements using an ancillary system, which acts as a local measuring device but which need not be perfectly prepared. We report an experimental realization using spin-bearing phosphorus impurities in silicon. The results demonstrate the necessity of a non-classical picture for this class of microscopic system. Our procedure can be applied to systems of any size, whether individually controlled or in a spatial ensemble.
|
|