Records |
Links |
|
Author |
Ozhegov, R. V.; Gorshkov, K. N.; Gol'tsman, G. N.; Kinev, N. V.; Koshelets, V. P. |
|
|
Title |
The stability of a terahertz receiver based on a superconducting integrated receiver |
Type |
Journal Article |
|
Year |
2011 |
Publication |
Supercond. Sci. Technol. |
Abbreviated Journal |
Supercond. Sci. Technol. |
|
|
Volume |
24 |
Issue |
3 |
Pages |
035003 |
|
|
Keywords |
SIS mixer, SIR, stability |
|
|
Abstract |
We present the results of stability testing of a terahertz radiometer based on a superconducting receiver with a SIS tunnel junction as the mixer and a flux-flow oscillator as the local oscillator. In the continuum mode, the receiver with a noise temperature of 95 K at 510 GHz measured over the intermediate frequency (IF) passband of 4-8 GHz offered a noise equivalent temperature difference of 10 ± 1 mK at an integration time of 1 s. We offer a method to significantly increase the integration time without the use of complex measurement equipment. The receiver observed a strong signal over a final detection bandwidth of 4 GHz and offered an Allan time of 5 s. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
RPLAB @ gujma @ |
Serial |
705 |
|
Permanent link to this record |
|
|
|
|
Author |
Tretyakov, Ivan; Ryabchun, Sergey; Finkel, Matvey; Maslennikova, Anna; Kaurova, Natalia; Lobastova, Anastasia; Voronov, Boris; Gol'tsman, Gregory |
|
|
Title |
Low noise and wide bandwidth of NbN hot-electron bolometer mixers |
Type |
Journal Article |
|
Year |
2011 |
Publication |
Appl. Phys. Lett. |
Abbreviated Journal |
Appl. Phys. Lett. |
|
|
Volume |
98 |
Issue |
|
Pages |
033507 (1 to 3) |
|
|
Keywords |
NbN HEB mixer |
|
|
Abstract |
We report a record double sideband noise temperature of 600 K (5hν/kB) offered by a NbN hot-electron bolometer receiver at 2.5 THz. Allowing for standing wave effects, this value was found to be constant in the intermediate frequency range 1–7 GHz, which indicates that the mixer has an unprecedentedly large noise bandwidth in excess of 7 GHz. The insight into this is provided by gain bandwidth measurements performed at the superconducting transition. They show that the dependence of the bandwidth on the mixer length follows the model for an HEB mixer with diffusion and phonon cooling of the hot electrons. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
RPLAB @ gujma @ |
Serial |
638 |
|
Permanent link to this record |
|
|
|
|
Author |
Kumar, Sushil; Chan, Chun Wang I.; Hu, Qing; Reno, John L. |
|
|
Title |
A 1.8-THz quantum cascade laser operating significantly above the temperature of hw/k |
Type |
Journal Article |
|
Year |
2011 |
Publication |
Nature Physics |
Abbreviated Journal |
|
|
|
Volume |
7 |
Issue |
|
Pages |
166-171 |
|
|
Keywords |
QCL, 2 mW at 155 K and 1.8 THz |
|
|
Abstract |
Several competing technologies continue to advance the field of terahertz science; of particular importance has been the development of a terahertz semiconductor quantum cascade laser (QCL), which is arguably the only solid-state terahertz source with average optical power levels of much greater than a milliwatt. Terahertz QCLs are required to be cryogenically cooled and improvement of their temperature performance is the single most important research goal in the field. Thus far, their maximum operating temperature has been empirically limited to ~planckω/kB, a largely inexplicable trend that has bred speculation that a room-temperature terahertz QCL may not be possible in materials used at present. Here, we argue that this behaviour is an indirect consequence of the resonant-tunnelling injection mechanism employed in all previously reported terahertz QCLs. We demonstrate a new scattering-assisted injection scheme to surpass this limit for a 1.8-THz QCL that operates up to ~1.9planckω/kB (163 K). Peak optical power in excess of 2 mW was detected from the laser at 155 K. This development should make QCL technology attractive for applications below 2 THz, and initiate new design strategies for realizing a room-temperature terahertz semiconductor laser. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
631 |
|
Permanent link to this record |
|
|
|
|
Author |
Манова, Н.Н.; Корнеева, Ю.П.; Корнеев, А.А.; Слыш, В.; Воронов, Б.М.; Гольцман, Г.Н. |
|
|
Title |
Сверхпроводниковый NbN однофотонный детектор, интегрированный с четвертьволновым резонатором |
Type |
Journal Article |
|
Year |
2011 |
Publication |
Письма в Журнал технической физики |
Abbreviated Journal |
ПЖТФ |
|
|
Volume |
37 |
Issue |
10 |
Pages |
7 |
|
|
Keywords |
SSPD |
|
|
Abstract |
Исследована спектральная зависимость квантовой эффективности сверхпроводниковых NbN однофотонных детекторов, интегрированных с оптическими четвертьволновыми резонаторами с использованием диэлектриков Si3N4, SiO2, SiO. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
RPLAB @ gujma @ |
Serial |
637 |
|
Permanent link to this record |
|
|
|
|
Author |
Ларионов, П.А.; Рябчун, С.А.; Финкель, М.И.; Гольцман, Г.Н. |
|
|
Title |
Вывешенный сверхпроводящий детектор терагерцового диапазона |
Type |
Journal Article |
|
Year |
2011 |
Publication |
Труды Московского физико-технического института |
Abbreviated Journal |
Труды МФТИ |
|
|
Volume |
3 |
Issue |
2 |
Pages |
29-30 |
|
|
Keywords |
вывешенный болометр, терагерцовый диапазон, сверхпроводящие пленки |
|
|
Abstract |
Рассматриваются технологические особенности создания чувствительного вывешен- ного детектора терагерцевого диапазона на основе плёнки MoRe. Предлагается воз- можный маршрут создания такого детектора и поясняется выбор материалов, ис- пользуемых для создания детектора. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
RPLAB @ gujma @ |
Serial |
645 |
|
Permanent link to this record |