Semenov, A. D., Gol’tsman, G. N., Gogidze, I. G., Sergeev, A. V., Gershenzon, E. M., Lang, P. T., et al. (1992). Subnanosecond photoresponse of a YBaCuO thin film to infrared and visible radiation by quasiparticle induced suppression of superconductivity. Appl. Phys. Lett., 60(7), 903–905.
Abstract: We observed subnanosecond photoresponse of a structured superconducting YBa2Cu3O7−δ thin film to infrared and visible radiation. We measured the voltage response of a current biased film (thickness 700 Å) in a resistive state to radiation pulses. From our results we conclude a response time of about 90 ps and a responsivity of about 4×1010 Ω/J. We attribute the response to Cooper pair breaking and suppression of the superconducting energy gap induced by nonequilibrium quasiparticles.
|
Semenov, A. D., Goghidze, I. G., Gol’tsman, G. N., Sergeev, A. V., & Gershenzon, E. M. (1993). Evidence for the spectral dependence of nonequilibrium picosecond photoresponse of YBaCuO thin films. Appl. Phys. Lett., 63(5), 681–683.
Abstract: The transient voltage photoresponse of current biased YBaCuO thin films to 20 ps laser pulses of 0.63 and 1.54 μm wavelengths is measured for temperatures around the superconducting transition region. The fast picosecond decay of the response is followed by a slow nanosecond relaxation which is associated with the bolometric effect. The magnitude of the fast component of the response varies in proportion to the square root of wavelength that plausibly reflects multiplication processes of photoexcited electrons via electron–electron scattering and interaction with high energy phonons.
|
Dickert, F. L., Haunschild, A., Kuschow, V., Reif, M., & Stathopulos, H. (1996). Mass-sensitive detection of solvent vapors. Mechanistic studies on host-guest sensor principles by FT-IR spectroscopy and BET adsorption analysis. Anal. Chem., 68(6), 1058–1061.
Abstract: Chemical sensors, based on highly mass sensitive QMB or SAW devices, coated with thin layers of calixarenes, enable the detection of organic solvent vapours, especially halogenated or aromatic hydrocarbons, down to a few ppm. Force field calculations allow the tailoring of these sensor materials seeing that the predicted interaction energies between the host molecules and a large variety of analytes are linearly correlated to the measured sensor effects. These correlations and also BET adsorption analysis prove the analyte recognition properties of these calixarene coatings to be mainly based on host/guest inclusion principles.
Keywords: supramolecular recognition, quartz crystal microbalance, QCM, surface acoustic wave, SAW, mass-sensitive sensor, detector, calixarenes, MM3 force field, Brunauer, Emmett and Teller theory, BET
|
Siemsen, K. J., Bernard, J. E., Madej, A. A., & Marmet, L. (2001). Absolute frequency measurement of a CO2/OsO4 stabilized laser at 28.8 THz. Appl. Phys. B: Lasers and Optics, 72, 567–573.
|
Nebosis, R. S., Steinke, R., Lang, P. T., Schatz, W., Heusinger, M. A., Renk, K. F., et al. (1992). Picosecond YBa2Cu3O7−δdetector for far‐infrared radiation. J. Appl. Phys., 72(11), 5496–5499.
Abstract: We report on a picosecond YBa2Cu3O7−δ detector for far‐infrared radiation. The detector, consisting of a current carrying structure cooled to liquid‐nitrogen temperature, was studied by use of ultrashort laser pulses from an optically pumped far‐infrared laser in the frequency range from 25 to 215 cm−1. We found that the sensitivity (1 mV/W) was almost constant in this frequency range. We estimated a noise equivalent power of less than 5×10−7 W Hz−1/2. Taking into account the results of a mixing experiment (in the frequency range from 4 to 30 cm−1) we suggest that the response time of the detector was few picoseconds.
|