Korneeva, Y., Florya, I., Vdovichev, S., Moshkova, M., Simonov, N., Kaurova, N., et al. (2017). Comparison of hot-spot formation in NbN and MoN thin superconducting films after photon absorption. In IEEE Transactions on Applied Superconductivity (Vol. 27, 5).
Abstract: In superconducting single-photon detectors SSPD
the efficiency of local suppression of superconductivity and hotspot
formation is controlled by diffusivity and electron-phonon
interaction time. Here we selected a material, 3.6-nm-thick MoNx
film, which features diffusivity close to those of NbN traditionally
used for SSPD fabrication, but with electron-phonon interaction
time an order of magnitude larger. In MoNx detectors we study
the dependence of detection efficiency on bias current, photon
energy, and strip width and compare it with NbN SSPD. We
observe non-linear current-energy dependence in MoNx SSPD
and more pronounced plateaus in dependences of detection
efficiency on bias current which we attribute to longer electronphonon
interaction time.
|
|
|
Gershenzon, E. M., Gol’tsman, G. N., Semenov, A. D., & Sergeev, A. V. (1991). Mechanism of picosecond response of granular YBaCuO films to electromagnetic radiation. IEEE Trans. Magn., 27(2), 1321–1324.
Abstract: Ultrafast mechanisms of radiation detection in granular YBaCuO films are studied in the wide wavelength range from millimeter waves to near infrared. With an increase in radiation frequency, the Josephson detection at the grain-boundary weak links is replaced by electron heating into the grains. This change occurs in the submillimeter wavelength range. The electron-phonon relaxation time tau /sub eph/ is determined from direct measurements, quasi-stationary electron heating measurements, and the frequency dependence of the current at which maximum voltage shift is observed. The temperature dependence of tau /sub eph/ at T<or=40 K was found to be tau /sub eph/ approximately T/sup -1/. The results show that detectors with a response time of a few picoseconds at nitrogen temperature are attainable.
|
|
|
González, F. J., & Boreman, G. D. (2005). Comparison of dipole, bowtie, spiral and log-periodic IR antennas. Inf Phys & Technol, 46(5), 418–428.
Abstract: Antenna-coupled microbolometers use planar lithographic antennas to couple infrared radiation into a bolometer with sub-micron dimensions. In this paper four different types of infrared antennas were fabricated on thin grounded-substrates and coupled to microbolometers. Dipole, bowtie, spiral and log-periodic IR antenna-coupled detectors were measured at 10.6 μm and their performance compared. A new method to calculate the radiation efficiency based on the spatial and angular response of infrared antennas is presented and used to evaluate their performance. The calculated radiation efficiency for the dipole, bowtie, spiral and log-periodic IR antennas was 20%, 37%, 25% and 46% respectively. A dipole-length study was performed and shows that the quasistatic value of the effective permittivity accurately describes the incident wavelength in the substrate at infrared frequencies for antennas on a thin substrate.
|
|
|
Gershenzon, E. M., Gol'tsman, G. N., Karasik, B. S., & Semenov, A. D. (1987). Measurement of the energy gap in the compound YBaCu3O9-δ on the basis of the IR absorption spectrum. JETP Lett., 46(5), 237–238.
Abstract: For the first time the long-wave infrared absorption spectrum has been measured by means of the bolometric effect and energy gap for high-temperature superconducting ceramics YBa/sub 2/Cu/sub 3/O/sub 9-delta/ has been determined from absorption threshold. 2delta/kT/sub c/ value is equal to 0.6.
|
|
|
Akhmadishina, K. F., Bobrinetskiy, I. I., Komarov, I. A., Malovichko, A. M., Nevolin, V. K., Fedorov, G. E., et al. (2015). Fast-response biological sensors based on single-layer carbon nanotubes modified with specific aptamers. Semicond., 49(13), 1749–1753.
Abstract: The possibility of the fabrication of a fast-response biological sensor based on a composite of single-layer carbon nanotubes and aptamers for the specific detection of proteins is shown. The effect of modification of the surface of the carbon nanotubes on the selectivity and sensitivity of the sensors is investigated. It is shown that carboxylated nanotubes have a better selectivity for detecting thrombin.
|
|