Arams, F., Allen, C., Peyton, B., & Sard, E. (1966). Millimeter mixing and detection in bulk InSb. In Proc. IEEE (Vol. 54, pp. 612–622).
|
Fedorov, G. E., Stepanova, T. S., Gazaliev, A. S., Gaiduchenko, I. A., Kaurova, N. S., Voronov, B. M., et al. (2016). Asymmetric devices based on carbon nanotubes for terahertz-range radiation detection. Semicond., 50(12), 1600–1603.
Abstract: Various asymmetric detecting devices based on carbon nanotubes (CNTs) are studied. The asymmetry is understood as inhomogeneous properties along the conducting channel. In the first type of devices, an inhomogeneous morphology of the CNT grid is used. In the second type of devices, metals with highly varying work functions are used as the contact material. The relation between the sensitivity and detector configuration is analyzed. Based on the data obtained, approaches to the development of an efficient detector of terahertz radiation, based on carbon nanotubes are proposed.
|
Akhmadishina, K. F., Bobrinetskiy, I. I., Komarov, I. A., Malovichko, A. M., Nevolin, V. K., Fedorov, G. E., et al. (2015). Fast-response biological sensors based on single-layer carbon nanotubes modified with specific aptamers. Semicond., 49(13), 1749–1753.
Abstract: The possibility of the fabrication of a fast-response biological sensor based on a composite of single-layer carbon nanotubes and aptamers for the specific detection of proteins is shown. The effect of modification of the surface of the carbon nanotubes on the selectivity and sensitivity of the sensors is investigated. It is shown that carboxylated nanotubes have a better selectivity for detecting thrombin.
|
Jiang, L. A., & Luu, J. X. (2008). Heterodyne detection with a weak local oscillator. Appl. Opt., 47(10), 1486–1503.
Abstract: eterodyne detection in the limit of weak (a few photons) local oscillator and signal power levels has been largely neglected in the past, as authors almost always assumed that the noise was dominated by the shot noise from a strong local oscillator. We present the theory for heterodyne detection of diffuse and specular targets at arbitrary power levels, including the case where the local oscillator power is only a few photons per coherent integration period. The theory was tested with experimental results, and was found to show good agreement. We show how to interpret the power spectral density of the heterodyne signal and how to determine the optimal number of signal and local oscillator photons per coherent integration.
|
González, F. J., & Boreman, G. D. (2005). Comparison of dipole, bowtie, spiral and log-periodic IR antennas. Inf Phys & Technol, 46(5), 418–428.
Abstract: Antenna-coupled microbolometers use planar lithographic antennas to couple infrared radiation into a bolometer with sub-micron dimensions. In this paper four different types of infrared antennas were fabricated on thin grounded-substrates and coupled to microbolometers. Dipole, bowtie, spiral and log-periodic IR antenna-coupled detectors were measured at 10.6 μm and their performance compared. A new method to calculate the radiation efficiency based on the spatial and angular response of infrared antennas is presented and used to evaluate their performance. The calculated radiation efficiency for the dipole, bowtie, spiral and log-periodic IR antennas was 20%, 37%, 25% and 46% respectively. A dipole-length study was performed and shows that the quasistatic value of the effective permittivity accurately describes the incident wavelength in the substrate at infrared frequencies for antennas on a thin substrate.
|
Gershenzon, E. M., Gol'tsman, G. N., Karasik, B. S., & Semenov, A. D. (1987). Measurement of the energy gap in the compound YBaCu3O9-δ on the basis of the IR absorption spectrum. JETP Lett., 46(5), 237–238.
Abstract: For the first time the long-wave infrared absorption spectrum has been measured by means of the bolometric effect and energy gap for high-temperature superconducting ceramics YBa/sub 2/Cu/sub 3/O/sub 9-delta/ has been determined from absorption threshold. 2delta/kT/sub c/ value is equal to 0.6.
|
Zhang, Z., Zhang, J., Wu, L., Zhang, Y., Zhao, Y., & Su, J. (2013). Photon-counting chirped amplitude modulation lidar using a smart premixing method. Opt. Lett., 38(21), 4389–4392.
Abstract: We proposed a new premixing method for photon-counting chirped amplitude modulation lidar (PCCAML). Earlier studies used the counting results of the returned signal detected by a Geiger mode avalanche photodiode detector (Gm-APD) to mix with the reference signal, called the postmixing method. We use an alternative method known as the premixing method, in which the reference signal is used to directly modulate the sampling gate width of the Gm-APD, and the mixing of the returned signal and the reference signal is completed before the Gm-APD. This premixing method is more flexible and may perform better than the postmixing method in terms of signal-to-noise ratio by cutting down a separated mixer commonly used in the postmixing lidar system. Furthermore, this premixing method lowers the demand for the sampling frequency of the Gm-APD. It allows the use of a much wider modulation bandwidth to improve the range accuracy and resolution. To the best of our knowledge, this is the first report to use the premixing method in the PCCAML system, which will benefit future lidar applications.
|
Gordon, N. T., Lees, D. J., Bowen, G., Phillips, T. S., Haigh, M., Jones, C. L., et al. (2006). HgCdTe detectors operating above 200 K. J. Electron. Mater., 35(6), 1140–1144.
|
Lubzens, D., Rosenfeld, D., & Nemirovsky, Y. (1988). The noise equivalent temperature difference performance of HgCdTe photodiode array. Infrared Physics, 28(6), 417–423.
|
Gershenzon, E. M., Gershenzon, M. E., Goltsman, G. N., Semenov, A. D., & Sergeev, A. V. (1991). Wide-band highspeed Nb and YBaCuO detectors. IEEE Trans. Magn., 27(2), 2836–2839.
Abstract: The physical limitations on the response time and the nature of nonequilibrium detection of radiation were investigated for Nb and YBCO film in a wide spectral range from millimeter to near-infrared wavelengths. In the case of ideal heat removal from the film, the detection mechanism is connected with an electron heating effect which is not selective over a wide spectral interval. For Nb, the dependence of the response time on the electron mean free path l and temperature T is tau varies as T/sup -2/l/sup -1/. The values of detectivity D* and tau are 3*10/sup 11/ W/sup -1/ Hz/sup 1/2/ cm and 5*10/sup -9/ s at T=1.6 K, respectively. For YBCO film the tau value of 1-2 ps at T=77 K was obtained; the NEP value of 3*10/sup -11/ W-Hz/sup -1/2/ can be obtained at T=77 K in the case of the optimal film matching to the radiation.
|
Korneeva, Y., Florya, I., Vdovichev, S., Moshkova, M., Simonov, N., Kaurova, N., et al. (2017). Comparison of hot-spot formation in NbN and MoN thin superconducting films after photon absorption. In IEEE Transactions on Applied Superconductivity (Vol. 27, 5).
Abstract: In superconducting single-photon detectors SSPD
the efficiency of local suppression of superconductivity and hotspot
formation is controlled by diffusivity and electron-phonon
interaction time. Here we selected a material, 3.6-nm-thick MoNx
film, which features diffusivity close to those of NbN traditionally
used for SSPD fabrication, but with electron-phonon interaction
time an order of magnitude larger. In MoNx detectors we study
the dependence of detection efficiency on bias current, photon
energy, and strip width and compare it with NbN SSPD. We
observe non-linear current-energy dependence in MoNx SSPD
and more pronounced plateaus in dependences of detection
efficiency on bias current which we attribute to longer electronphonon
interaction time.
|
Gershenzon, E. M., Gol’tsman, G. N., Semenov, A. D., & Sergeev, A. V. (1991). Mechanism of picosecond response of granular YBaCuO films to electromagnetic radiation. IEEE Trans. Magn., 27(2), 1321–1324.
Abstract: Ultrafast mechanisms of radiation detection in granular YBaCuO films are studied in the wide wavelength range from millimeter waves to near infrared. With an increase in radiation frequency, the Josephson detection at the grain-boundary weak links is replaced by electron heating into the grains. This change occurs in the submillimeter wavelength range. The electron-phonon relaxation time tau /sub eph/ is determined from direct measurements, quasi-stationary electron heating measurements, and the frequency dependence of the current at which maximum voltage shift is observed. The temperature dependence of tau /sub eph/ at T<or=40 K was found to be tau /sub eph/ approximately T/sup -1/. The results show that detectors with a response time of a few picoseconds at nitrogen temperature are attainable.
|
Ferrari, S., Kovalyuk, V., Hartmann, W., Vetter, A., Kahl, O., Lee, C., et al. (2017). Hot-spot relaxation time current dependence in niobium nitride waveguide-integrated superconducting nanowire single-photon detectors. Opt. Express, 25(8), 8739–8750.
Abstract: We investigate how the bias current affects the hot-spot relaxation dynamics in niobium nitride. We use for this purpose a near-infrared pump-probe technique on a waveguide-integrated superconducting nanowire single-photon detector driven in the two-photon regime. We observe a strong increase in the picosecond relaxation time for higher bias currents. A minimum relaxation time of (22 +/- 1)ps is obtained when applying a bias current of 50% of the switching current at 1.7 K bath temperature. We also propose a practical approach to accurately estimate the photon detection regimes based on the reconstruction of the measured detector tomography at different bias currents and for different illumination conditions.
|
Seliverstov, S., Maslennikov, S., Ryabchun, S., Finkel, M., Klapwijk, T. M., Kaurova, N., et al. (2015). Fast and sensitive terahertz direct detector based on superconducting antenna-coupled hot electron bolometer. IEEE Trans. Appl. Supercond., 25(3), 2300304.
Abstract: We characterize superconducting antenna-coupled hot-electron bolometers for direct detection of terahertz radiation operating at a temperature of 9.0 K. The estimated value of responsivity obtained from lumped-element theory is strongly different from the measured one. A numerical calculation of the detector responsivity is developed, using the Euler method, applied to the system of heat balance equations written in recurrent form. This distributed element model takes into account the effect of nonuniform heating of the detector along its length and provides results that are in better agreement with the experiment. At a signal frequency of 2.5 THz, the measured value of the optical detector noise equivalent power is 2.0 × 10-13 W · Hz-0.5. The value of the bolometer time constant is 35 ps. The corresponding energy resolution is about 3 aJ. This detector has a sensitivity similar to that of the state-of-the-art sub-millimeter detectors operating at accessible cryogenic temperatures, but with a response time several orders of magnitude shorter.
|
Zhang, W., Miao, W., Li, S. L., Zhou, K. M., Shi, S. C., Gao, J. R., et al. (2013). Measurement of the spectral response of spiral-antenna coupled superconducting hot electron bolometers. IEEE Trans. Appl. Supercond., 23(3), 2300804.
Abstract: Measured spectral response of spiral-antenna coupled superconducting hot electron bolometers (HEBs) often drops dramatically at frequencies that are still within the frequency range of interest (e.g., ~ 5 THz). This is inconsistent with the implied low receiver noise temperatures from the same measurements. To understand this discrepancy, we exhaustively test and calibrate the thermal sources used in Fourier transform spectrometer measurements. We first investigate the absolute emission spectrum of high-pressure Hg arc lamp, then measure the spectral response of two spiral-antenna coupled NbN HEBs with a Martin-Puplett interferometer as spectrometer and 77 K blackbody as broadband signal source. The measured absolute emission spectrum of Hg arc lamp is proportional to frequency, corresponding to an equivalent blackbody temperature of 4000 K at 1 THz, 1500 K at 3 THz, and 800 K at 5 THz, respectively. Measured spectral response of spiral-antenna coupled NbN HEBs, corrected for air absorption, is nearly flat in the frequency range of 0.5-4 THz, consistent with simulated coupling efficiency between HEB and spiral-antenna. These results explain the discrepancy, and prove that spiral-antenna coupled superconducting NbN HEBs work well in a wide frequency range. In addition, this calibration method and these results are broadly applicable to other quasi-optical THz receivers.
|