Gol'tsman, G. N. (1999). Hot electron bolometric mixers: new terahertz technology. Infrared Physics & Technology, 40(3), 199–206.
Abstract: This paper presents an overview of recent results for NbN phonon-cooled hot electron bolometric (HEB) mixers. The noise temperature of the receivers based on both quasioptical and waveguide versions of HEB mixers has crossed the level of 1 K GHz−1 at 430 GHz (410 K), 600–650 GHz (480 K), 750 GHz (600 K), 810 GHz (780 K) and is close to that level at 1.1 THz (1250 K) and 2.5 THz (4500 K). The gain bandwidth measured for quasioptical HEB mixer at 620 GHz reached 4 GHz and the noise temperature bandwidth was almost 8 GHz. Local oscillator power requirements are about 1 μW for mixers made by photolithography and about 100 nW for mixers made by e-beam lithography. A waveguide version of 800 GHz receiver was installed at the Submillimeter Telescope Observatory on Mt. Graham, AZ, to conduct astronomical observations of known submillimeter lines (CO, J=7→6, CI, J=2→1). It was proved that the receiver works as a practical instrument.
|
|
|
Zhang, J., Boiadjieva, N., Chulkova, G., Deslandes, H., Gol'tsman, G. N., Korneev, A., et al. (2003). Noninvasive CMOS circuit testing with NbN superconducting single-photon detectors. Electron. Lett., 39(14), 1086–1088.
Abstract: The 3.5 nm thick-film, meander-structured NbN superconducting single-photon detectors have been implemented in the CMOS circuit-testing system based on the detection of near-infrared photon emission from switching transistors and have significantly improved the performance of the system. Photon emissions from both p- and n-MOS transistors have been observed.
|
|
|
Manova, N. N., Korneeva, Y. P., Korneev, A. A., Slysz, W., Voronov, B. M., & Gol'tsman, G. N. (2011). Superconducting NbN single-photon detector integrated with quarter-wave resonator. Tech. Phys. Lett., 37(5), 469–471.
Abstract: The spectral dependence of the quantum efficiency of superconducting NbN single-photon detectors integrated with quarter-wave resonators based on Si3N4, SiO2, and SiO layers has been studied.
|
|
|
Slysz, W., Wegrzecki, M., Bar, J., Grabiec, P., Gol'tsman, G. N., Verevkin, M., et al. (2004). NbN superconducting single-photon detectors coupled with a communication fiber (Vol. 37).
|
|
|
Gershenzon, E. M., Gol'tsman, G. N., & Ptitsina, N. G. (1973). Submillimeter spectroscopy of semiconductors. Sov. Phys. JETP, 37(2), 299–304.
Abstract: The possibility is considered of carrying out submillimeter-wave spectral investigations of semiconductors by means of a high resolution spectrometer with backward-wave tubes. Results of a study of the excitation spectra of small impurities, D-(A +) centers and free excitons in germanium are presented.
|
|
|
Slysz, W., Wegrzecki, M., Papis, E., Gol'tsman, G. N., Verevkin, A., & Sobolewski, R. (2004). A method of optimization of the NbN superconducting single-photon detector (Vol. 36).
|
|
|
Gershenzon, E. M., Gershenzon, M. E., Gol'tsman, G. N., Semenov, A. D., & Sergeev, A. V. (1982). Nonselective effect of electromagnetic radiation on a superconducting film in the resistive state. JETP Lett., 36(7), 296–299.
|
|
|
Korneev, A., Minaeva, O., Rubtsova, I., Milostnaya, I., Chulkova, G., Voronov, B., et al. (2005). Superconducting single-photon ultrathin NbN film detector. Quantum Electronics, 35(8), 698–700.
Abstract: Superconducting single-photon ultrathin NbN film detectors are studied. The development of manufacturing technology of detectors and the reduction of their operating temperature down to 2 K resulted in a considerable increase in their quantum efficiency, which reached in the visible region (at 0.56 μm) 30%—40%, i.e., achieved the limit determined by the absorption coefficient of the film. The quantum efficiency exponentially decreases with increasing wavelength, being equal to ~20% at 1.55 μm and ~0.02% at 5 μm. For the dark count rate of ~10-4s-1, the experimental equivalent noise power was 1.5×10-20 W Hz-1/2; it can be decreased in the future down to the record low value of 5×10-21 W Hz-1/2. The time resolution of the detector is 30 ps.
|
|
|
Aksaev, E. E., Gershenzon, E. M., Gol'tsman, G. N., Mirskij, G. I., & Semenov, A. D. (1991). Submillimetric spectrometer-relaxometer based on backward-wave tubes with picosecond time resolution. Pribory i Tekhnika Eksperimenta, 34(2), 125–131.
Abstract: The high-sensitive automatic spectrometer-relaxometer based on backward-wave tubes in the range of 4÷0.25 mm was described permitting to study the response kinetics of sample under investigation in any point of this range with the resolution time of 10-11 s. The relaxation measurements were conducted using oscillation beats of two adequate tubes, the frequency of one of them was fixed, while that of the other one was changeable. The amplitude-frequency characteristic of the response under the conditions of synchronous reception was recorded at beat frequency variation from 107 to 1010 Hz. The high sensitivity was reached by decreasing the device recording band down to 100 Hz in the whole measuring range.
|
|
|
Gershenzon, E., Gershenzon, M. E., Gol'tsman, G. N., Semenov, A. D., & Sergeev, A. V. (1981). Heating of quasiparticles in a superconducting film in the resistive state. JETP Lett., 34(5), 268–271.
|
|