|
Ekström H, Kroug M, Belitsky V, Kollberg E, Olsson H, Goltsman G, et al. Hot electron mixers for THz applications. In: Rolfe EJ, Pilbratt G, editors. Proc. 30th ESLAB.; 1996. p. 207–10.
Abstract: We have measured the noise performance of 35 A thin NbN HEB devices integrated with spiral antennas on antireflection coated silicon substrate lenses at 620 GHz. From the noise measurements we have determined a total conversion gain of the receiver of—16 dB, and an intrinsic conversion of about-10 dB. The IF bandwidth of the 35 A thick NbN devices is at least 3 GHz. The DSB receiver noise temperature is less than 1450 K. Without mismatch losses, which is possible to obtain with a shorter device, and with reduced loss from the beamsplitter, we expect to achieve a DSB receiver noise temperature of less ‘than 700 K.
|
|
|
Gerecht E, Musante CF, Yngvesson KS, Waldman J, Gol'tsman GN, Yagoubov PA, et al. Optical coupling and conversion gain for NbN HEB mixer at THz frequencies. In: Proc. 4-th Int. Semicond. Device Research Symp.; 1997. p. 47–50.
|
|
|
Verevkin AA, Ptitsina NG, Smirnov KV, Gol'tsman GN, Voronov BM, Gershenzon EM, et al. Hot electron bolometer detectors and mixers based on a superconducting-two-dimensional electron gas-superconductor structure. In: Proc. 4-th Int. Semicond. Device Research Symp.; 1997. p. 163–6.
|
|
|
Antipov SV, Vachtomin YB, Maslennikov SN, Smirnov KV, Kaurova NS, Grishina EV, et al. Noise performance of quasioptical ultrathin NbN hot electron bolometer mixer at 2.5 and 3.8 THz. In: Proc. 5-th MSMW. Vol 2. Kharkov, Ukraine; 2004. p. 592–4.
Abstract: To put space-based and airborne heterodyne instruments into operation at frequencies above 1 THz the superconducting NbN hot-electron bolometer (HEB) will be incorporated into heterodyne receiver as a mixer. At frequencies above 1.3 THz the sensitivity of the NbN HEB mixers outperform the one of the Schottky diodes and SIS-mixers, and the receiver noise temperature of the NbN HEB mixers increase with frequency. In this paper we present the results of the noise temperature measurements within one batch of NbN HEB mixers based on 3.5 mn thick superconducting NbN film grown on Si substrate with MgO buffer layer at the LO frequencies 2.5 THz and 3.8 THz.
|
|
|
Zolotov PI, Vakhtomin YB, Divochiy AV, Seleznev VA, Smirnov KV. Technology development of resonator-based structures for efficiency increasing of NBN detectors of IR single photons. Proc 5th Int Conf Photonics and Information Optics. 2016:115–6.
Abstract: This paper presents a technology of fabrication of NbN superconductive single- photon detectors, using resonator structures. The main results are related to optimization of the process of NbN sputtering over substrate with metallic mirrors and SiO 2 /Si 3 N 4 layers /4 thick. Investigation of the quantum efficiency of fabricated devices at 1.6 K on 1.55 μm showed triple-magnified value compared to standard Si/NbN structures.
|
|
|
Gol'tsman G, Jacobsson S, Ekstrom H, Karasik B, Kollberg E, Gershenzon E. Slot-line tapered antenna with NbN hot electron mixer for 300-360 GHz operation. In: Proc. 5th Int. Symp. Space Terahertz Technol.; 1994. p. 209–213a.
Abstract: NbN hot-electron mixers combined with slot-line tapered antennas on Si wdnitride membranes had been fabricated. Several strips of 1 gm wide and 5 tan long made from 100 A NbN film are inserted into the slot antenna. IV-curves under local oscillator power in 300-350 GHz frequency range and conversion gain dependencies on intermediate fre- quency in the 0.1-1 GHz range are measured and compared with that for 100 GHz frequency band. Our results show that pumped IV-curves and intermediate frequency bands are different for 100 GHz and 300 GHz frequency ranges. The interpretation exploits the fact that for the lowest radiation frequency the superconducting energy gap is larger than the radiation quantum energy while they are comparable at the higher frequency. Tha results show that such mixers have good perspectives for terahertz receiving technology.
|
|
|
0kunev 0., Dzardanov A, Ekstrom H, Jacobsson S, Kollberg E, Gol'tsman G, et al. NbN hot electron waveguide mixer for 100 GHz operation. In: Proc. 5th Int. Symp. Space Terahertz Technol.; 1994. p. 214–24.
Abstract: NbN is a promising superconducting material used to develope hot- electron superconducting mixers with an IF bandwidth over 1 GHz. In the 100 GHz frequency range, the following parameters were obtained for NbN films 50 A thick: the noise temperature of the receiver (DSB) 1000 K; the conversion losses 10 d13, the IF bandwidth 1 GHz; the local oscillator power 1 /LW. An increase of NbN film thickness up to 80-100 A and increase of working temperature up to 7-8 K, and a better mixer matching may allow to broader the IF band up to 3 Gllz, to reduce the conversion losses down to 3-5 dB and the noise tempera- ture down to 200-300 K.
|
|
|
Blundell R, Kawamura JH, Tong CE, Papa DC, Hunter TR, Gol’tsman GN, et al. A hot-electron bolometer mixer receiver for the 680-830 GHz frequency range. In: Proc. 6-th Int. Conf. Terahertz Electron. IEEE; 1998. p. 18–20.
Abstract: We describe a heterodyne receiver designed to operate in the partially transparent atmospheric windows centered on 680 and 830 GHz. The receiver incorporates a niobium nitride thin film, cooled to 4.2 K, as the phonon-cooled hot-electron mixer element. The double sideband receiver noise, measured over the frequency range 680-830 GHz, is typically 700-1300 K. The instantaneous output bandwidth of the receiver is 600 MHz. This receiver has recently been used at the SubMillimeter Telescope, jointly operated by the Steward Observatory and the Max Planck Institute for Radioastronomy, for observations of the neutral carbon and CO spectral lines at 810 GHz and at 806 and 691 GHz respectively. Laboratory measurements on a second mixer in the same test receiver have yielded extended high frequency performance to 1 THz.
|
|
|
Yagoubov P, Kroug M, Merkel H, Kollberg E, Schubert J, Hubers H-W, et al. Performance of NbN phonon-cooled hot-electron bolometric mixer at Terahertz frequencies. In: Proc. 6-th Int. Conf. Terahertz Electron.; 1998. p. 149–52.
Abstract: The performance of a NbN based phonon-cooled Hot Electron Bolometric (HEB) quasioptical mixer is investigated in the 0.65-3.12 THz frequency range. The device is made from a 3 nm thick NbN film on high resistivity Si and integrated with a planar spiral antenna on the same substrate. The in-plane dimensions of the bolometer strip are 0.2/spl times/2 /spl mu/m. The results of the DSB noire temperature are: 1300 K at 650 GHz, 4700 K at 2.5 TBz and 10000 K at 3.12 THz. The RF bandwidth of the receiver is at least 2.5 THz. The amount of LO power absorbed in the bolometer is about 100 nW. The mixer is linear to within 1 dB compression up to the signal level 10 dB below that of the LO. The intrinsic single sideband conversion gain is measured to be -9 dB, the total conversion gain -14 dB.
|
|
|
Semenov A, Richter H, Hübers H-W, Smirnov K, Voronov B, Gol'tsman G. Development of terahertz superconducting hot-electron bolometer mixers. In: Proc. 6th European Conf. Appl. Supercond. Vol 181.; 2003. p. 2960–5.
Abstract: We present recent results of the development of phonon cooled hot-electron bolometric (HEB) mixers for airborne and balloon borne terahertz heterodyne receivers. Three iomportant issues have been addresses: the quality of NbN films the HEB mixers were made from, the spectral properties of the HEB mixers and the local oscillator power required for optical operation. Studies with an atomic force microscope indicate, that the performance of the HEB mixer might have been effected by the microstructure of the NbN film. Antenna gain and noise temperature were investigated at terahertz frequencies for a HEB embedded in either log-spiral or twin-slot feed antenna. Comparison suggests that at frequencies above 3 THz the spiral feed provides better overall performance. At 1.6 THz, a power of 2.5 µW was required from the local oscillator for optimal operation of the HEB mixer.
|
|