|
Chuprina IN, An PP, Zubkova EG, Kovalyuk VV, Kalachev AA, Gol'tsman GN. Optimisation of spontaneous four-wave mixing in a ring microcavity. In: J. Phys.: Conf. Ser. Vol 47.; 2017. p. 887–91.
Abstract: Abstract. A theory of spontaneous four-wave mixing in a ring microcavity is developed. The rate of emission of biphotons for pulsed and monochromatic pumping with allowance for the disper- sion of group velocities is analytically calculated. In the first case, pulses in the form of an increasing exponential are considered, which are optimal for excitation of an individual resonator mode. The behaviour of the group velocity dispersion as a function of the width and height of the waveguide is studied for a specific case of a ring microcavity made of silicon nitride. The results of the numeri- cal calculation are in good agreement with the experimental data. The ring microcavity is made of two types of waveguides: com- pletely etched and half etched. It is found that the latter allow for better control over the parameters in the manufacturing process, making them more predictable.
|
|
|
Gershenzon EM, Gol'tsman GN, Ptitsina NG, Riger ER. Effect of electron-electron collisions on the trapping of free carriers by shallow impurity centers in germanium. Sov Phys JETP. 1986;64(4):889–97.
Abstract: Cascade Auger recombination of free carriers on shallow impurities in Ge is investigated under quasi-equilibrium conditions (T= 2-12 K) and in impurity breakdown. The Auger capture cross sections are found to be a,= 5. 10-l9 T-'n cm2 for donors and uip= 7- T-5p cm2 for acceptors. It is shown that in an isotropic semiconductor (p-Ge) ui is well described by the cascade-capture theory that takes into account only electron-electron collisions. In an anisotropic semiconductor ui is considerably larger (n-Ge, strongly uniaxially compressedp-Ge). Under impurity breakdown conditions the electron-electron collisions determine the lifetimes of the free carriers only in samples with appreciable density of the compensating impurity (Nk loi3 cmP3).
|
|
|
Gershenson EM, Gol'tsman GN, Elant'ev AI, Kagane ML, Multanovskii VV, Ptitsina NG. Use of submillimeter backward-wave tube spectroscopy in determination of the chemical nature and concentration of residual impurities in pure semiconductors. Sov Phys Semicond. 1983;17(8):908–13.
|
|
|
Voronov BM, Gershenzon EM, Gol'tsman GN, Gogidze IG, Gusev YP, Zorin MA, et al. Picosecond range detector base on superconducting niobium nitride film sensitive to radiation in spectral range from millimeter waves up to visible light. Sverkhprovodimost': Fizika, Khimiya, Tekhnika. 1992;5(5):955–60.
Abstract: Fast-operating picosecond detector of electromagnetical radiation is developed on the basis of fine superconducting film of niobium nitride with high sensitivity within spectral range from millimetric waves up to visible light. Detector sensitive element represents structure covering narrow parallel strips with micron sizes included in the rupture of microstrip line. Detecting ability of the detector and time constant measured using amplitude-simulated radiation of reverse wave tubes and pulse radiation of picosecond gas and solid-body lasers, constitute D*≅1010 W-1·cm·Hz-1/2 and τ≤5 ps respectively, at 10 K temperature. The expected value of time constant of the detector at 10 K obtained via extrapolation of directly measured dependence that is, τ ∝ τ-1, constitutes 20 ps. Experimental data demonstrate that detection mechanism is linked with electron heating effect.
|
|
|
Zhang J, Boiadjieva N, Chulkova G, Deslandes H, Gol'tsman GN, Korneev A, et al. Noninvasive CMOS circuit testing with NbN superconducting single-photon detectors. Electron Lett. 2003;39(14):1086–8.
Abstract: The 3.5 nm thick-film, meander-structured NbN superconducting single-photon detectors have been implemented in the CMOS circuit-testing system based on the detection of near-infrared photon emission from switching transistors and have significantly improved the performance of the system. Photon emissions from both p- and n-MOS transistors have been observed.
|
|
|
Voronov BM, Gershenzon EM, Gol'tsman GN, Gubkina TO, Semash VD. Superconductive properties of ultrathin NbN films on different substrates. Sverkhprovodimost': Fizika, Khimiya, Tekhnika. 1994;7(6):1097–102.
Abstract: A study was made on dependence of surface resistance, critical temperature and width of superconducting transition on application temperature and thickness of NbN films, which varied within the range of 3-10 nm. Plates of sapphire, fused and monocrystalline quartz, MgO, as well as Si and silicon oxide were used as substrates. NbN films with 160 μθ·cm specific resistance and 16.5 K (Tc) critical temperature were obtained on sapphire substrates. Intensive growth of ΔTc was noted for films, applied on fused quartz, with increase of precipitation temperature. This is explained by occurrence of high tensile stresses in NbN films, caused by sufficient difference of thermal coefficients of expansion of NbN and quartz.
|
|
|
Gershenzon EM, Gol'tsman GN, Karasik BS, Lugovaya GY, Serebryakova NA, Chinkova EV. Infrared radiation detectors on the base of electron heating in resistive state films from traditional superconducing materials. Sverkhprovodimost': Fizika, Khimiya, Tekhnika. 1992;5(6):1129–40.
Abstract: Characteristics of infrared radiation detectors based on electron heating in thin superconducting films transformed at T ≤ Tc to a resistive state by transport current and, if necessary, by magnetic field are investigated. A comparison is made of the characteristics of the detectors fabricated of different materials: aluminium, niobium, Mo0.5Re0.5. Some devices with different topology of the reception area are considered. Electron heating detectors are comparable by their sensitivity with superconducting bolometers, but differ in a high fast-response.
|
|
|
Morozov P, Lukina M, Shirmanova M, Divochiy A, Dudenkova V, Gol'tsman GN, et al. Singlet oxygen phosphorescence imaging by superconducting single-photon detector and time-correlated single-photon counting. Opt Lett. 2021;46(6):1217–20.
Abstract: This Letter presents, to the best of our knowledge, a novel optical configuration for direct time-resolved measurements of luminescence from singlet oxygen, both in solutions and from cultured cells on photodynamic therapy. The system is based on the superconducting single-photon detector, coupled to the confocal scanner that is modified for the near-infrared measurements. The recording of a phosphorescence signal from singlet oxygen at 1270 nm has been done using time-correlated single-photon counting. The performance of the system is verified by measuring phosphorescence from singlet oxygen generated by the photosensitizers commonly used in photodynamic therapy: methylene blue and chlorin e6. The described system can be easily upgraded to the configuration when both phosphorescence from singlet oxygen and fluorescence from the cells can be detected in the imaging mode. Thus, co-localization of the signal from singlet oxygen with the areas inside the cells can be done.
|
|
|
Gol'tsman GN, Gusinskii EN, Malyavkin AV, Ptitsina NG, Selevko AG, Edel'shtein VM. The excitonic Zeeman effect in uniaxially-strained germanium. Sov Phys JETP. 1987;65(6):1233–41.
Abstract: We have carried out a high-resolution spectroscopic study of the absorption of submillimeter radiation by free excitons in germanium compressed along the [ 1 11 ] axis in a magnetic field parallel to the compression axis. In particular, we studied the splitting of the 1s- 2p transition in fields up to 6 kOe at T = 1.6 K, and observed a complex pattern in the Zeeman splitting which we believe is related to the effect of thermal motion of the excitons in a magnetic field on their internal structure (the magneto-Stark effect). The calculated submillimeter spectrum of excitons agrees with the experimental data. We predict that in a magnetic field the energy of the 2p, term is a minimum at a finite value of the exciton momentum perpendicular to the field-that is, the energy minimum forms a ring in momentum space. It follows that the density of states for this term must be a nonmonotonic function of the energy. A theory is developed of analogous phenomena in positronium.
|
|
|
Varyukhin SV, Zakharov AA, Gershenzon EM, Gol'tsman GN, Ptitsyna NG, Chulkova GM. AC losses and submillimeter absorption in single crystals La2CuO4. Phys B Condens Mat. 1990;165-166:1269–70.
Abstract: The La2CuO4 single crystals were used to carry out the measurements of transmission spectra within the submillimeter range of wavelengths, as well as the capacitance C and conductivity G in the region of acoustic frequencies of the metal-dielectric-La2Cu04 system at low temperatures. The optical spectra display a threshold character. There takes place a sharp decreasing of transmission signal in the energy range of hυ>1.5meV. The C(ω,T) and G(ω,T) dependences have a universal form characteristic of relaxation processes of the Debye type. The relaxation time dependence displays a thermoactivation character τ(T)-exp(ξ/T) with a gap value of ξ≃2meV,coinciding with the optical one. It is assumed that there exist excitations with a characteristic energy ~ 2meV in La2Cu04.A possible nature of the revealed low-energy excitations is discussed.
|
|