Verevkin AA, Pearlman A, Slysz W, Zhang J, Sobolewski R, Chulkova G, et al. Ultrafast superconducting single-photon detectors for infrared wavelength quantum communications. In: Donkor E, Pirich AR, Brandt HE, editors. Proc. SPIE. Vol 5105. SPIE; 2003. p. 160–70.
Abstract: We have developed a new class of superconducting single-photon detectors (SSPDs) for ultrafast counting of infrared (IR) photons for secure quantum communications. The devices are operated on the quantum detection mechanism, based on the photon-induced hotspot formation and subsequent appearance of a transient resistive barrier across an ultrathin and submicron-wide superconducting stripe. The detectors are fabricated from 3.5-nm-thick NbN films and they operate at 4.2 K inside a closed-cycle refrigerator or liquid helium cryostat. Various continuous and pulsed laser sources have been used in our experiments, enabling us to determine the detector experimental quantum efficiency (QE) in the photon-counting mode, response time, time jitter, and dark counts. Our 3.5-nm-thick SSPDs reached QE above 15% for visible light photons and 5% at 1.3 – 1.5 μm infrared range. The measured real-time counting rate was above 2 GHz and was limited by the read-out electronics (intrinsic response time is <30 ps). The measured jitter was <18 ps, and the dark counting rate was <0.01 per second. The measured noise equivalent power (NEP) is 2 x 10-18 W/Hz1/2 at λ = 1.3 μm. In near-infrared range, in terms of the counting rate, jitter, dark counts, and overall sensitivity, the NbN SSPDs significantly outperform their semiconductor counterparts. An ultrafast quantum cryptography communication technology based on SSPDs is proposed and discussed.
|
Zhang J, Pearlman A, Slysz W, Verevkin A, Sobolewski R, Okunev O, et al. Infrared picosecond superconducting single-photon detectors for CMOS circuit testing. In: CLEO/QELS. Optical Society of America; 2003. Cmv4.
Abstract: Novel, NbN superconducting single-photon detectors have been developed for ultrafast, high quantum efficiency detection of single quanta of infrared radiation. Our devices have been successfully implemented in a commercial VLSI CMOS circuit testing system.
|
Verevkin AA, Zhang J, Slysz W, Sobolewski R, Lipatov AP, Okunev O, et al. Superconducting single-photon detectors for GHz-rate free-space quantum communications. In: Ricklin JC, Voelz DG, editors. Proc. SPIE. Vol 4821. SPIE; 2002. p. 447–54.
Abstract: We report our studies on the performance of new NbN ultrathin-film superconducting single-photon detectors (SSPDs). Our SSPDs exhibit experimentally measured quantum efficiencies from 5% at wavelength λ = 1550 nm up to 10% at λ = 405 nm, with exponential, activation-energy-type spectral sensitivity dependence in the 0.4-μm – 3-μm wavelength range. Using a variable optical delay setup, we have shown that our NbN SSPDs can resolve optical photons with a counting rate up to 10 GHz, presently limited by the read-out electronics. The measured device jitter was below 35 ps under optimum biasing conditions. The extremely high photon counting rate, together with relatively high (especially for λ > 1 μm) quantum efficiency, low jitter, and very low dark counts, make NbN SSPDs very promising for free-space communications and quantum cryptography.
|
Semenov AD, Hübers H-W, Gol’tsman GN, Smirnov K. Superconducting quantum detector for astronomy and X-ray spectroscopy. In: Pekola J, Ruggiero B, Silvestrini P, editors. Proc. Int. Workshop on Supercond. Nano-Electronics Devices. : Springer; 2002. p. 201–10.
Abstract: We propose the novel concept of ultra-sensitive energy-dispersive superconducting quantum detectors prospective for applications in astronomy and X-ray spectroscopy. Depending on the superconducting material and operation conditions, such detector may allow realizing background limited noise equivalent power 10−21 W Hz−1/2 in the terahertz range when exposed to 4-K background radiation or counting of 6-keV photon with almost 10—4 energy resolution. Planar layout and relatively simple technology favor integration of elementary detectors into a detector array.
|
Hübers H-W, Semenov A, Richter H, Birk M, Krocka M, Mair U, et al. Terahertz Heterodyn Receiver with a hot-electron bolometer mixer. In: Wolf U, Farhoomand J, McCreight CR, editors. Far-IR, Sub-mm & MM Detector Technology Workshop. NASA; 2002. p. 3–24. (NASA CP).
Abstract: During the past decade major advances have been made regarding low noise mixers for terahertz (THz) heterodyne receivers. State of the art hot-electron-bolometer (HEB) mixers have noise temperatures close to the quantum limit and require less than a µW power from the local oscillator (LO). The technology is now at a point where the performance of a practical receiver employing such mixer, rather than the figures of merit of the mixer itself, are of major concern. We have incorporated a phonon-cooled NbN HEB mixer in a 2.5 THz heterodyne receiver and investigated the performance of the receiver. This yields important information for the development of heterodyne receivers such as GREAT (German receiver for astronomy at THz frequencies aboard SOFIA) [1] and TELIS (Terahertz limb sounder), a balloon borne heterodyne receiver for atmospheric research [2]. Both are currently under development at DLR.
|