|
Ferrari S, Kovalyuk V, Hartmann W, Vetter A, Kahl O, Lee C, et al. Hot-spot relaxation time current dependence in niobium nitride waveguide-integrated superconducting nanowire single-photon detectors. Opt Express. 2017;25(8):8739–50.
Abstract: We investigate how the bias current affects the hot-spot relaxation dynamics in niobium nitride. We use for this purpose a near-infrared pump-probe technique on a waveguide-integrated superconducting nanowire single-photon detector driven in the two-photon regime. We observe a strong increase in the picosecond relaxation time for higher bias currents. A minimum relaxation time of (22 +/- 1)ps is obtained when applying a bias current of 50% of the switching current at 1.7 K bath temperature. We also propose a practical approach to accurately estimate the photon detection regimes based on the reconstruction of the measured detector tomography at different bias currents and for different illumination conditions.
|
|
|
Teich MC. Infrared heterodyne detection. In: Proc. IEEE. Vol 56. IEEE; 1968. p. 37–46.
Abstract: Heterodyne experiments have been performed in the middle infrared region of the electromagnetic spectrum using the CO2laser as a radiation source. Theoretically optimum operation has been achieved at kHz heterodyne frequencies using photoconductive Ge:Cu detectors operated at 4°K, and at kHz and MHz frequencies using Pb1-xSnxSe photovoltaic detectors at 77°K. In accordance with the theory, the minimum detectable power observed is a factor of 2/η greater than the theoretically perfect quantum counter, hvΔf. The coefficient 2/η varies from 5 to 25 for the detectors investigated in this study. A comparison is made between photoconductive and photodiode detectors for heterodyne use in the infrared, and it is concluded that both are useful. Heterodyne detection at 10.6 µm is expected to be useful for communications applications, infrared radar, and heterodyne spectroscopy. It has particular significance because of the high radiation power available from the CO2laser, and because of the 8 to 14 µm atmospheric window.
|
|
|
Zhang J, Pearlman A, Slysz W, Verevkin A, Sobolewski R, Okunev O, et al. Infrared picosecond superconducting single-photon detectors for CMOS circuit testing. In: CLEO/QELS. Optical Society of America; 2003. Cmv4.
Abstract: Novel, NbN superconducting single-photon detectors have been developed for ultrafast, high quantum efficiency detection of single quanta of infrared radiation. Our devices have been successfully implemented in a commercial VLSI CMOS circuit testing system.
|
|
|
Soifer BT, Pipher JL. Instrumentation for infrared astronomy. Annual Rev. Astron. Astrophys.. 1978;16(1):335–69.
|
|
|
Käufl HU, Rothermal H, Drapatz S. Investigation of the Martian atmosphere by 10 micron heterodyne spectroscopy. A&A. 1984;136:319–25.
Keywords: astronomical spectroscopy, atmospheric composition, infrared astronomy, mars atmosphere, spectral line width, carbon dioxide concentration, nonequilibrium thermodynamics, optical heterodyning, planetary radiation, mars, atmosphere, spectroscopy, atmosphere, carbon dioxide, altitude, kinetics, rotation, thermal properties, temperature, emissions, intensity, models, data, spectra
|
|