Details
   web
Records
Author (up) Engel, Andreas; Aeschbacher, Adrian; Inderbitzin, Kevin; Schilling, Andreas; Il'in, Konstantin; Hofherr, Matthias; Siegel, Michael; Semenov, Alexei; Hübers, Heinz-Wilhelm
Title Tantalum nitride superconducting single-photon detectors with low cut-off energy Type Journal Article
Year 2011 Publication arXiv Abbreviated Journal arXiv
Volume Issue Pages 9
Keywords SSPD
Abstract Materials with a small superconducting energy gap favor a high detection efficiency of low-energy photons in superconducting nanowire single-photon detectors. We developed a TaN detector with smaller gap and lower density of states at the Fermi energy than in comparable NbN devices, while other relevant parameters remain essentially unchanged. This results in a reduction of the minimum photon energy required for direct detection to $\approx1/3$ as compared to NbN.
Address
Corporate Author Thesis
Publisher Place of Publication arXiv:1110.4576 Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number RPLAB @ gujma @ Serial 687
Permanent link to this record
 

 
Author (up) Julia Toussaint, Roman Grüner, Marco Schubert, Torsten May, Hans-Georg Meyer, Benjamin Dietzek, Jürgen Popp, Matthias Hofherr, Matthias Arndt, Dagmar Henrich, Konstantin Il'in, and Michael Siegel
Title Superconducting single-photon counting system for optical experiments requiring time-resolution in the picosecond range Type Journal Article
Year 2012 Publication Abbreviated Journal AIP REVIEW OF SCIENTIFIC INSTRUMENTS
Volume 83 Issue Pages
Keywords SSPD, picosecond, time-resolution
Abstract We have developed a cryogenic measurement system for single-photon counting, which can be used

in optical experiments requiring high time resolution in the picosecond range. The system utilizes

niobium nitride superconducting nanowire single-photon detectors which are integrated in a timecorrelated

single-photon counting (TCSPC) setup. In this work, we describe details of the mechanical

design, the electrical setup, and the cryogenic optical components. The performance of the complete

system in TCSPC mode is tentatively benchmarked using 140 fs long laser pulses at a repetition

frequency of 75MHz. Due to the high temporal stability of these pulses, the measured time resolution

of 35 ps (FWHM) is limited by the timing jitter of the measurement system. The result was crosschecked

in a Coherent Anti-stokes Raman Scattering (CARS) setup, where scattered pulses from a

β-barium borate crystal have been detected with the same time resolution.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number RPLAB @ seleznev @ Serial 885
Permanent link to this record