Hartogh, P., Jarchow, C., Lellouch, E., de Val-Borro, M., Rengel, M., Moreno, R., et al. (2010). Herschel/HIFI observations of Mars: First detection of O2 at submillimetre wavelengths and upper limits on HCl and H2O2. Astron. Astrophys., 521, L49.
Abstract: We report on an initial analysis of Herschel/HIFI observations of hydrogen chloride (HCl), hydrogen peroxide (H2O2), and molecular oxygen (O2) in the Martian atmosphere performed on 13 and 16 April 2010 (Ls ~ 77°). We derived a constant volume mixing ratio of 1400 ± 120 ppm for O2 and determined upper limits of 200 ppt for HCl and 2 ppb for H2O2. Radiative transfer model calculations indicate that the vertical profile of O2 may not be constant. Photochemical models determine the lowest values of H2O2 to be around Ls ~ 75° but overestimate the volume mixing ratio compared to our measurements.
|
Bennett, D. A., Schmidt, D. R., Swetz, D. S., & Ullom, J. N. (2014). Phase-slip lines as a resistance mechanism in transition-edge sensors. Appl. Phys. Lett., 104, 042602.
Abstract: The fundamental mechanism of resistance in voltage-biased superconducting films is poorly understood despite its importance as the basis of transition-edge sensors (TESs). TESs are utilized in state-of-the-art microbolometers and microcalorimeters covering a wide range of energies and applications. We present a model for the resistance of a TES based on phase-slip lines (PSLs) and compare the model to data. One of the model's predictions, discrete changes in the number of PSLs, is a possible explanation for the observed switching between discrete current states in localized regions of bias.
|
Steudle, G. A., Schietinger, S., Höckel, D., Dorenbos, S. N., Zadeh, I. E., Zwiller, V., et al. (2012). Measuring the quantum nature of light with a single source and a single detector. Phys. Rev. A, 86(5), 053814.
Abstract: An elementary experiment in optics consists of a light source and a detector. Yet, if the source generates nonclassical correlations such an experiment is capable of unambiguously demonstrating the quantum nature of light. We realized such an experiment with a defect center in diamond and a superconducting detector. Previous experiments relied on more complex setups, such as the Hanbury Brown and Twiss configuration, where a beam splitter directs light to two photodetectors, creating the false impression that the beam splitter is a fundamentally required element. As an additional benefit, our results provide a simplification of the widely used photon-correlation techniques.
|
Hoevers, H. F. C., Bento, A. C., Bruijn, M. P., Gottardi, L., Korevaar, M. A. N., Mels, W. A., et al. (2000). Thermal fluctuation noise in a voltage biased superconducting transition edge thermometer. Appl. Phys. Lett., 77(26), 4421–4424.
Abstract: The current noise at the output of a microcalorimeter with a voltage biased superconducting transition edge thermometer is studied in detail. In addition to the two well-known noise sources: thermal fluctuation noise from the heat link to the bath and Johnson noise from the resistive thermometer, a third noise source strongly correlated with the steepness of the thermometer is required to fit the measured noise spectra. Thermal fluctuation noise, originating in the thermometer itself, fully explains the additional noise. A simple model provides quantitative agreement between the observed and calculated noise spectra for all bias points in the superconducting transition.
|
Prober, D. E. (1993). Superconducting terahertz mixer using a transition-edge microbolometer. Appl. Phys. Lett., 62(17), 2119–2121.
|