Verevkin, A. A., Ptitsina, N. G., Smirnov, K. V., Gol’tsman, G. N., Gershenzon, E. M., & Ingvesson, K. S. (1996). Direct measurements of energy relaxation times on an AlGaAs/GaAs heterointerface in the range 4.2–50 K. JETP Lett., 64(5), 404–409.
Abstract: The temperature dependence of the energy relaxation time τe (T) of a two-dimensional electron gas at an AlGaAs/GaAs heterointerface is measured under quasiequilibrium conditions in the region of the transition from scattering by acoustic phonons to scattering with the participation of optical phonons. The temperature interval of constant τe, where scattering by the deformation potential predominates, is determined. In the preceding, low-temperature region, where piezoacoustic and deformation-potential-induced scattering processes coexist, τ e decreases slowly with increasing temperature. Optical phonons start to participate in the scattering processes at T∼25 K (the characteristic phonon lifetime was equal to τLOτ4.5 ps). The energy losses calculated from the τe data in a model with an effective nonequilibrium electron temperature agree with the published data obtained under strong heating conditions.
|
Karasik, B. S., & Elantiev, A. I. (1996). Noise temperature limit of a superconducting hot-electron bolometer mixer. Appl. Phys. Lett., 68(6), 853–855.
|
Karasik, B. S., Il'in, K. S., Pechen, E. V., & Krasnosvobodtsev, S. I. (1996). Diffusion cooling mechanism in a hot-electron NbC microbolometer mixer. Appl. Phys. Lett., 68(16), 2285–2287.
|
Dickert, F. L., Haunschild, A., Kuschow, V., Reif, M., & Stathopulos, H. (1996). Mass-sensitive detection of solvent vapors. Mechanistic studies on host-guest sensor principles by FT-IR spectroscopy and BET adsorption analysis. Anal. Chem., 68(6), 1058–1061.
Abstract: Chemical sensors, based on highly mass sensitive QMB or SAW devices, coated with thin layers of calixarenes, enable the detection of organic solvent vapours, especially halogenated or aromatic hydrocarbons, down to a few ppm. Force field calculations allow the tailoring of these sensor materials seeing that the predicted interaction energies between the host molecules and a large variety of analytes are linearly correlated to the measured sensor effects. These correlations and also BET adsorption analysis prove the analyte recognition properties of these calixarene coatings to be mainly based on host/guest inclusion principles.
Keywords: supramolecular recognition, quartz crystal microbalance, QCM, surface acoustic wave, SAW, mass-sensitive sensor, detector, calixarenes, MM3 force field, Brunauer, Emmett and Teller theory, BET
|
Trifonov, V. A., Karasik, B. S., Zorin, M. A., Gol’tsman, G. N., Gershenzon, E. M., Lindgren, M., et al. (1996). 9.6 μm wavelength mixing in a patterned YBa2Cu3O7‐δ thin film. Appl. Phys. Lett., 68(10), 1418–1420.
Abstract: Hot‐electron bolometric (HEB) mixing of 9.6 μm infrared radiation from two lasers in high‐quality YBa2Cu3O7−δ (YBCO) patterned thin film has been demonstrated. A heterodyne measurement showed an intermediate frequency (IF) bandwidth of 18 GHz, limited by our measurement system. An intrinsic limit of 100 GHz is predicted. Between 0.1 and 1 GHz intermediate frequency, temperature fluctuations with an equivalent output noise temperature Tfl up to ∼150 K, contributed to the mixer noise while Johnson noise dominated above 1 GHz. The overall conversion loss at 77 K at low intermediate frequencies was measured to be ∼25 dB, of which 13 dB was due to the coupling loss. The HEB mixer is very promising for use in heterodyne receivers within the whole infrared range.
|