Kitaeva, G. K., Kornienko, V. V., Kuznetsov, K. A., Pentin, I. V., Smirnov, K. V., & Vakhtomin, Y. B. (2019). Direct detection of the idler THz radiation generated by spontaneous parametric down-conversion. Opt. Lett., 44(5), 1198–1201.
Abstract: We study parametric down-conversion (PDC) of optical laser radiation in the strongly frequency non-degenerate regime which is promising for the generation of quantum-correlated pairs of extremely different spectral ranges, the optical and the terahertz (THz) ones. The possibility to detect tenuous THz-frequency photon fluxes generated under low-gain spontaneous PDC is demonstrated using a hot electron bolometer. Then experimental dependences of the THz radiation power on the detection angle and on the pump intensity are analyzed.
|
Romanov, N. R., Zolotov, P. I., & Smirnov, K. V. (2019). Development of disordered ultra-thin superconducting vanadium nitride films. In Proc. 8th Int. Conf. Photonics and Information Optics (pp. 425–426).
Abstract: We present the results of development and research of superconducting vanadium nitride VN films ~10 nm thick having different level of disorder. It is showed that both silicon substrate temperature T sub in process of magnetron sputtering and total gas pressure P affect superconducting transition temperature of sputtered films and R 300 /R 20 ratio defining their level of disorder. VN films suitable for development of superconducting single-photon detectors on their basis are obtained.
|
Moshkova, M. A., Divochiy, A. V., Morozov, P. V., Antipov, A. V., Vakhtomin, Y. B., & Smirnov, K. V. (2019). Characterization of topologies of superconducting photon number resolving detectors. In Proc. 8th Int. Conf. Photonics and Information Optics (pp. 465–466).
Abstract: Comparative analysis for different topologies of superconducting single-photon detectors with ability to resolve up to 4 photons in a short pulse of IR radiation has been carry out. It was developed the detector with a system detection efficiency of ~ 85 % at λ = 1550 nm. The possibility of using such detector to restore photon statistics of a pulsed radiation source was demonstrated.
|
Shcheslavskiy, V., Morozov, P., Divochiy, A., Vakhtomin, Y., Smirnov, K., & Becker, W. (2016). Erratum: “Ultrafast time measurements by time-correlated single photon counting coupled with superconducting single photon detector” [Rev. Sci. Instrum. 87, 053117 (2016)] (Vol. 87).
Abstract: In the original paper1the Ref. 10 should be M. Sanzaro, N. Calandri, A. Ruggeri, C. Scarcella, G. Boso, M. Buttafava, and A. Tosi, Proc. SPIE9370, 93701T (2015).
|
Zolotov, P. I., Vakhtomin, Y. B., Divochiy, A. V., Seleznev, V. A., & Smirnov, K. V. (2016). Technology development of resonator-based structures for efficiency increasing of NBN detectors of IR single photons. Proc. 5th Int. Conf. Photonics and Information Optics, , 115–116.
Abstract: This paper presents a technology of fabrication of NbN superconductive single- photon detectors, using resonator structures. The main results are related to optimization of the process of NbN sputtering over substrate with metallic mirrors and SiO 2 /Si 3 N 4 layers /4 thick. Investigation of the quantum efficiency of fabricated devices at 1.6 K on 1.55 μm showed triple-magnified value compared to standard Si/NbN structures.
|