|
Records |
Links |
|
Author |
Ryabchun, S.; Tong, C.-yu E.; Blundell, R.; Kimberk, R.; Gol’tsman, G. |
|
|
Title |
Effect of microwave radiation on the stability of terahertz hot-electron bolometer mixers |
Type |
Conference Article |
|
Year |
2006 |
Publication |
Proc. SPIE |
Abbreviated Journal |
Proc. SPIE |
|
|
Volume |
6373 |
Issue |
|
Pages |
63730J (1 to 5) |
|
|
Keywords |
NbN HEB mixers, hot-electron bolometer mixers, stability, Allan variance, LO power fluctuations |
|
|
Abstract |
We report our studies of the effect of microwave radiation, with a frequency much lower than that corresponding to the energy gap of the superconductor, on the performance of the NbN hot-electron bolometer (HEB) mixer incorporated into a THz heterodyne receiver. It is shown that exposing the HEB mixer to microwave radiation does not result in a significant rise of the receiver noise temperature and degradation of the mixer conversion gain so long as the level of microwave power is small compared to the local oscillator drive. Hence the injection of a small, but controlled amount of microwave radiation enables active compensation of local oscillator power and coupling fluctuations which can significantly degrade the stability of HEB mixer receivers. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
SPIE |
Place of Publication |
|
Editor |
Anwar, M.; DeMaria, A.J.; Shur, M.S. |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
Terahertz Physics, Devices, and Systems |
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1441 |
|
Permanent link to this record |
|
|
|
|
Author |
Bennett, Douglas A.; Schmidt, Daniel R.; Swetz, Daniel S.; Ullom, Joel N. |
|
|
Title |
Phase-slip lines as a resistance mechanism in transition-edge sensors |
Type |
Journal Article |
|
Year |
2014 |
Publication |
Appl. Phys. Lett. |
Abbreviated Journal |
Appl. Phys. Lett. |
|
|
Volume |
104 |
Issue |
|
Pages |
042602 |
|
|
Keywords |
microbolometers, TES, phase-slip lines, PSL |
|
|
Abstract |
The fundamental mechanism of resistance in voltage-biased superconducting films is poorly understood despite its importance as the basis of transition-edge sensors (TESs). TESs are utilized in state-of-the-art microbolometers and microcalorimeters covering a wide range of energies and applications. We present a model for the resistance of a TES based on phase-slip lines (PSLs) and compare the model to data. One of the model's predictions, discrete changes in the number of PSLs, is a possible explanation for the observed switching between discrete current states in localized regions of bias. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
Recommended by Klapwijk |
Approved |
no |
|
|
Call Number |
|
Serial |
929 |
|
Permanent link to this record |
|
|
|
|
Author |
Hoevers, H. F. C.; Bento, A. C.; Bruijn, M. P.; Gottardi, L.; Korevaar, M. A. N.; Mels, W. A.; de Korte, P. A. J. |
|
|
Title |
Thermal fluctuation noise in a voltage biased superconducting transition edge thermometer |
Type |
Journal Article |
|
Year |
2000 |
Publication |
Applied Physics Letters |
Abbreviated Journal |
Appl. Phys. Lett. |
|
|
Volume |
77 |
Issue |
26 |
Pages |
4421-4424 |
|
|
Keywords |
TES; bolometer; thermal fluctuation noise; TFN |
|
|
Abstract |
The current noise at the output of a microcalorimeter with a voltage biased superconducting transition edge thermometer is studied in detail. In addition to the two well-known noise sources: thermal fluctuation noise from the heat link to the bath and Johnson noise from the resistive thermometer, a third noise source strongly correlated with the steepness of the thermometer is required to fit the measured noise spectra. Thermal fluctuation noise, originating in the thermometer itself, fully explains the additional noise. A simple model provides quantitative agreement between the observed and calculated noise spectra for all bias points in the superconducting transition. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
RPLAB @ gujma @ |
Serial |
759 |
|
Permanent link to this record |
|
|
|
|
Author |
Irwin, K.D. |
|
|
Title |
Thermodynamics of nonlinear bolometers near equilibrium |
Type |
Conference Article |
|
Year |
2006 |
Publication |
Proc. 11th International Workshop on Low Temp. Detectors |
Abbreviated Journal |
Proc. 11th International Workshop on Low Temp. Detectors |
|
|
Volume |
559 |
Issue |
2 |
Pages |
718-720 |
|
|
Keywords |
bolometers, microcalorimeters, nonlinear thermodynamics, nonequilibrium |
|
|
Abstract |
We present the first thermodynamically correct calculation of the noise in a simple nonlinear resistive bolometer or calorimeter operated out of equilibrium. The solution is rigorous only for first- and second-order deviations from equilibrium, and for the linear and quadratic terms of dissipative elements. In contrast, existing models of noise in resistive bolometers are based on the application of equilibrium theories to a system that is often nonlinear and out of equilibrium. We derive solutions applicable both in and out of steady state. The noise has power spectral density different from the equilibrium theory, and it has higher-order correlations and non-Gaussian characteristics. The results do not apply to non-Markovian hidden variables in the bolometer. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
Recommended by Klapwijk |
Approved |
no |
|
|
Call Number |
|
Serial |
915 |
|
Permanent link to this record |
|
|
|
|
Author |
González, F. J.; Boreman, G. D. |
|
|
Title |
Comparison of dipole, bowtie, spiral and log-periodic IR antennas |
Type |
Journal Article |
|
Year |
2005 |
Publication |
Infrared Physics & Technology |
Abbreviated Journal |
Inf Phys & Technol |
|
|
Volume |
46 |
Issue |
5 |
Pages |
418-428 |
|
|
Keywords |
optical antennas; Microbolometer; Infrared antennas; Antenna efficiency; Antenna-coupled detectors |
|
|
Abstract |
Antenna-coupled microbolometers use planar lithographic antennas to couple infrared radiation into a bolometer with sub-micron dimensions. In this paper four different types of infrared antennas were fabricated on thin grounded-substrates and coupled to microbolometers. Dipole, bowtie, spiral and log-periodic IR antenna-coupled detectors were measured at 10.6 μm and their performance compared. A new method to calculate the radiation efficiency based on the spatial and angular response of infrared antennas is presented and used to evaluate their performance. The calculated radiation efficiency for the dipole, bowtie, spiral and log-periodic IR antennas was 20%, 37%, 25% and 46% respectively. A dipole-length study was performed and shows that the quasistatic value of the effective permittivity accurately describes the incident wavelength in the substrate at infrared frequencies for antennas on a thin substrate. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
RPLAB @ gujma @ |
Serial |
739 |
|
Permanent link to this record |